Fabrication of a Mandibular Implant-Supported Overdenture with a New Attachment System: A Review of Current Attachment Systems

被引:14
|
作者
Shah, Karnik [1 ]
Yilmaz, Burak [1 ]
McGlumphy, Edwin [1 ]
机构
[1] Ohio State Univ, Coll Dent, Adv Prosthodont Program, Div Restorat Sci & Prosthodont, Columbus, OH 43210 USA
关键词
D O I
10.11607/ijp.5068
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Since their introduction, implant-retained overdentures have represented a feasible, economical, and highly successful treatment option for completely edentulous patients. Different attachment systems have been effectively used to retain these implant overdentures, and each system has advantages and disadvantages. Locator attachment (Zest Anchors) is one system that has been widely used by clinicians, particularly, for two-implant supported situations. Recently, Zest Anchors developed a new locator-style abutment, Locator R-Tx. This clinical report describes the fabrication of a mandibular two-implant overdenture using this newly designed attachment system and reviews the different attachment systems currently in clinical use.
引用
收藏
页码:245 / 247
页数:3
相关论文
共 50 条
  • [41] Fabrication of an implant-supported overdenture using CAD/CAM technology: A clinical report
    Rinke, Sven
    Ziebolz, Dirk
    QUINTESSENCE INTERNATIONAL, 2013, 44 (02): : 127 - 134
  • [42] Retention of CAD-CAM locator retentive attachment insert in mandibular implant overdenture
    Diab, Mai Hassan
    Abdelaziz, Medhat Sameh
    Eldin, Mohamed Hatem Kamal
    BMC ORAL HEALTH, 2025, 25 (01):
  • [43] METAL-REINFORCED SINGLE IMPLANT MANDIBULAR OVERDENTURE RETAINED BY AN ATTACHMENT: A CLINICAL REPORT
    Grageda, Edgar
    Rieck, Bastian
    JOURNAL OF PROSTHETIC DENTISTRY, 2014, 111 (01): : 16 - 19
  • [44] Implant Stability Changes for Nonsubmerged and Submerged Protocols for a Single Implant Mandibular Overdenture Using Ball Attachment
    Salah, Ahmed
    Foda, Karim
    Abdalla, Mohamed Farouk
    Aal, Marwa Abdel
    Naguib, Amr
    Nabi, Nouran Abdel
    INTERNATIONAL JOURNAL OF DENTISTRY, 2021, 2021
  • [45] Biomaterial aspects: A key factor in the longevity of implant overdenture attachment systems
    Daou, Elie E.
    JOURNAL OF INTERNATIONAL SOCIETY OF PREVENTIVE AND COMMUNITY DENTISTRY, 2015, 5 (04): : 255 - 262
  • [46] The In Vitro Comparison of the Retention of an Implant-Supported Stud Attachment Locator and Straumann Ball Attachment at Different Angulations
    Kurtulus, I. L.
    Gurbulak, A. G.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2018, 21 (05) : 639 - 644
  • [47] Mandibular implant-retained overdenture relining procedure with an attachment system A step-by-step demonstration of the technique
    Polychronakis, Nick
    Kontakiotis, Giorgos
    Soldatos, Nikolaos
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2018, 149 (01): : 67 - 71
  • [48] Telescopic Magnetic Attachment for Implant-Supported Denture: Evaluation of Splint Effect
    Chen, JianRong
    Tomotake, Yoritoki
    Watanabe, Megumi
    Ishida, Yuichi
    Nagao, Kan
    Ichikawa, Tetsuo
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2011, 26 (03) : 657 - 664
  • [49] Fabrication of a maxillary implant-supported overdenture retained by two cemented bars: A clinical report
    Uludag, Bulent
    Sahin, Volkan
    Celik, Gozde
    JOURNAL OF PROSTHETIC DENTISTRY, 2007, 97 (05): : 249 - 251
  • [50] Combination of Digital and Conventional Workflows in the CAD/CAM-Fabrication of an Implant-Supported Overdenture
    Schmidt, Michael Benno
    Rauch, Angelika
    Schwarzer, Marcus
    Lethaus, Bernd
    Hahnel, Sebastian
    MATERIALS, 2020, 13 (17)