Hepatocyte growth factor and 24-hour ambulatory blood pressure monitoring

被引:0
|
作者
Hayashi, Y [1 ]
Saitoh, S [1 ]
Takagi, S [1 ]
Tuchihashi, K [1 ]
Miura, T [1 ]
Shimamoto, K [1 ]
机构
[1] Sapporo Med Univ, Dept Internal Med 2, Chuo Ku, Sapporo, Hokkaido 0608543, Japan
关键词
hepatocyte growth factor (HGF); ambulatory blood pressure monitoring (ABPM); hypertension;
D O I
暂无
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
In recent years, many growth factors and cytokines have been shown to be related to arteriosclerosis, and hepatocyte growth factor (HGF) has been reported to be associated with hypertension. In the present study, we investigated the relationship between HGF and hypertension by measuring the serum HGF concentration and performing 24-h ambulatory blood pressure monitoring (ABPM) in 47 randomly selected male and female subjects who underwent a medical examination for cardiovascular disease. The results were as follows. 1) The mean serum HGF concentration in the subjects was 0.35 +/- 0.14 ng/ml. 2) The serum HGF concentration was positively correlated with both the nighttime systolic and diastolic blood pressures (r = 0.42, p < 0.05 and r = 0.47, p < 0.01, respectively). 3)No correlation was found between serum HGF concentration and daytime systolic or diastolic blood pressure. 4) When subjects were divided into two groups based on the difference between daytime and nighttime systolic blood pressure, i.e., a group in which the difference was less than 10 mmHg and a group in which the difference was 10 mmHg or more, the HGF concentration was significantly higher in the former group (0.39 +/- 0.14 vs. 0.30 +/- 0.12 ng/ml, p < 0.05); similarly, when subjects were divided into a group in which the difference between daytime and nighttime diastolic blood pressure was 5 mmHg and a group in which the difference was 5 mmHg or more, the HGF concentration was significantly higher in the former group (0.42 +/- 0.15 vs. 0.31 +/- 0.12 ng/ml, p < 0.05). The results indicated that there is a relationship between blood pressure measured by ABPM and serum HGF concentration, and that this relationship might be an index of damage to blood vessels in patients with hypertension.
引用
收藏
页码:655 / 660
页数:6
相关论文
共 50 条
  • [11] Comparison of Optimal Diagnostic Thresholds of Hypertension With Home Blood Pressure Monitoring and 24-Hour Ambulatory Blood Pressure Monitoring
    Park, Jin-Sun
    Rhee, Moo-Yong
    Namgung, June
    Lee, Sung Yun
    Cho, Deok-Kyu
    Choi, Tae-Young
    Kim, Seok Yeon
    Kim, Jang Young
    Park, Sang Min
    Choi, Jae Hyuk
    Lee, Jae Hang
    Kim, Hae-Young
    AMERICAN JOURNAL OF HYPERTENSION, 2017, 30 (12) : 1170 - 1176
  • [12] Usefulness of 24-hour ambulatory blood pressure monitoring in a population with high cardiovascular risk
    Navarro-Ulloa, Orlando D.
    Picon-Jaimes, Yelson A.
    Conde-Cardona, Giancarlos
    Fernandez-Yepez, Luis J.
    Zabala-Carballo, Carmen, I
    Lopez-Garcia, Jonathan
    Gomez-Hernandez, Angelica M.
    Orozco-Chinome, Javier E.
    Moscote-Salazar, Luis R.
    CIRUGIA Y CIRUJANOS, 2020, 88 (05): : 617 - 623
  • [13] Utility of 24-hour ambulatory blood pressure monitoring in potential living kidney donors
    Nabeel Aslam
    Sobia H. Memon
    Hani Wadei
    Elizabeth R. Lesser
    Shehzad K. Niazi
    Clinical Hypertension, 27
  • [14] Impact of obesity on 24-hour ambulatory blood pressure and hypertension
    Kotsis, V
    Stabouli, S
    Bouldin, M
    Low, A
    Toumanidis, S
    Zakopoulos, N
    HYPERTENSION, 2005, 45 (04) : 602 - 607
  • [15] Association between metabolic syndrome and parameters of 24-hour blood pressure ambulatory monitoring
    Felisbino-Mendes, Mariana Santos
    Gea-Horta, Tatiane
    Pinho Ribeiro, Antonio Luiz
    Kac, Gilberto
    de Fatima Silqueira, Salete Maria
    Velasquez-Melendez, Gustavo
    ARQUIVOS BRASILEIROS DE ENDOCRINOLOGIA E METABOLOGIA, 2011, 55 (06) : 383 - 388
  • [16] Diagnostic Comparability and Interchangeability Between Daytime Ambulatory Blood Pressure Monitoring and 24-Hour Ambulatory Blood Pressure Monitoring in Detecting Masked Hypertension
    Kinsara, Abdulhalim J.
    Abuosa, Ahmed
    Meer, Alaa
    Elsheikh, Aymen H.
    Abrar, Mohammed
    Vriz, Olga
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2020, 12 (11)
  • [17] Variability of circadian blood pressure profile during 24-hour ambulatory blood pressure monitoring in hypertensive patients
    Salwa, Pawel
    Gorczyca-Michta, Iwona
    Kluk, Maciej
    Dziubek, Katarzyna
    Wozakowska-Kaplon, Beata
    KARDIOLOGIA POLSKA, 2014, 72 (05) : 432 - 437
  • [18] Elevated pulse pressure in treated hypertensive patients during 24-hour ambulatory blood pressure monitoring
    Strbova, J.
    Kmecova, J.
    Klimas, J.
    BRATISLAVA MEDICAL JOURNAL-BRATISLAVSKE LEKARSKE LISTY, 2011, 112 (10): : 562 - 567
  • [19] Comparisons of Office and 24-Hour Ambulatory Blood Pressure Monitoring in Children with Obstructive Sleep Apnea
    Kang, Kun-Tai
    Chiu, Shuenn-Nan
    Weng, Wen-Chin
    Lee, Pei-Lin
    Hsu, Wei-Chung
    JOURNAL OF PEDIATRICS, 2017, 182 : 177 - 183
  • [20] The antihypertensive efficacy of the combination of irbesartan and hydrochlorothiazide assessed by 24-hour ambulatory blood pressure monitoring
    Howe, P
    Phillips, P
    Saini, R
    Kassler-Taub, K
    CLINICAL AND EXPERIMENTAL HYPERTENSION, 1999, 21 (08) : 1373 - 1396