Coronary artery calcium scoring using multicardiac computed tomography

被引:12
作者
Horiguchi, J
Nakanishi, T
Tamura, A
Ito, K
机构
[1] Hiroshima Univ, Dept Radiol, Div Med Intelligence & Informat, Program Appl Biomed,Grad Sch Biomed Sci, Hiroshima 730, Japan
[2] MAZDA Hosp, Dept Radiol, Hiroshima, Japan
关键词
coronary artery; calcium; CT;
D O I
10.1097/00004728-200211000-00004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To test the hypothesis that multicardiac-phase computed tomography (CT) improves the quantification of coronary artery calcium, Methods: Calcium-phosphate on a cardiac phantom and 108 calcified plaques , from) 50 patients were scanned, and multicardiac-phase images Were obtained. Motion artifacts and calcium scores of the calcified plaques were compared between cardiac phases and CT scanners, Results: In the phantom images, motion artifact differed between cardiac phases: thus, the calcium scores Were either higher or lower than the score from the static state. In the patient study, motion artifacts of calcifications an the various coronary branches varied with the cardiac cycle, which profoundly influenced the calcium scores. Conclusion: Multicardiac-phase CT has the potential to improve the quantification of coronary artery calcium by determining the cardiac phase where motion artifacts are the least on individual calcified plaques.
引用
收藏
页码:880 / 885
页数:6
相关论文
共 17 条
[1]   In-plane coronary arterial motion velocity: Measurement with electron-beam CT [J].
Achenbach, S ;
Ropers, D ;
Holle, J ;
Muschiol, G ;
Daniel, WG ;
Moshage, W .
RADIOLOGY, 2000, 216 (02) :457-463
[2]   QUANTIFICATION OF CORONARY-ARTERY CALCIUM USING ULTRAFAST COMPUTED-TOMOGRAPHY [J].
AGATSTON, AS ;
JANOWITZ, WR ;
HILDNER, FJ ;
ZUSMER, NR ;
VIAMONTE, M ;
DETRANO, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (04) :827-832
[3]   Helical and single-slice conventional CT versus electron beam CT for the quantification of coronary artery calcification [J].
Becker, CR ;
Jakobs, TF ;
Aydemir, S ;
Becker, A ;
Knez, A ;
Schoepf, UJ ;
Bruening, R ;
Haberl, R ;
Reiser, MF .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (02) :543-547
[4]  
BECKER CR, 2001, AM J ROENTGENOL, V176, P1925
[5]   Coronary artery disease: Improved reproducibility of calcium scoring with an electron-beam CT volumetric method [J].
Callister, TQ ;
Cooil, B ;
Raya, SP ;
Lippolis, NJ ;
Russo, DJ ;
Raggi, P .
RADIOLOGY, 1998, 208 (03) :807-814
[6]   Evaluation of subsecond gated helical CT for quantification of coronary artery calcium and comparison with electron beam CT [J].
Carr, JJ ;
Crouse, JR ;
Goff, DC ;
D'Agostino, RB ;
Peterson, NP ;
Burke, GL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (04) :915-921
[7]   ECG-gated reconstructed multi-detector row CT coronary angiography:: Effect of varying trigger delay on image quality [J].
Hong, C ;
Becker, CR ;
Huber, A ;
Schoepf, UJ ;
Ohnesorge, B ;
Knez, A ;
Brüning, R ;
Reiser, MF .
RADIOLOGY, 2001, 220 (03) :712-717
[8]   Quantification of coronary artery calcium using multidetector CT and a retrospective ECG-gating reconstruction algorithm [J].
Horiguchi, J ;
Nakanishi, T ;
Ito, K .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 177 (06) :1429-1435
[9]   Coronary arteries: Retrospectively ECG-gated multi-detector row CT angiography with selective optimization of the image reconstruction window [J].
Kopp, AF ;
Schroeder, S ;
Kuettner, A ;
Heuschmid, M ;
Georg, C ;
Ohnesorge, B ;
Kuzo, R ;
Claussen, CD .
RADIOLOGY, 2001, 221 (03) :683-688
[10]   Effect of electrocardiogram triggering on reproducibility of coronary artery calcium scoring [J].
Mao, SS ;
Bakhsheshi, H ;
Lu, B ;
Liu, SCK ;
Oudiz, RJ ;
Budoff, MJ .
RADIOLOGY, 2001, 220 (03) :707-711