The effect of high applied voltages on bioanodes of microbial electrolysis cells in the presence of chlorides

被引:33
作者
Baek, Gahyun [1 ]
Shi, Le [1 ]
Rossi, Ruggero [1 ]
Logan, Bruce E. [1 ]
机构
[1] Penn State Univ, Dept Civil & Environm Engn, 231Q Sackett Bldg, University Pk, PA 16802 USA
关键词
Bioanode; Electrochemical disinfection; Free chlorine species; Hydrogen production; Microbial electrolysis cell;
D O I
10.1016/j.cej.2020.126742
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
While most microbial electrolysis cell (MEC) tests and other bioelectrochemical tests use applied voltages (E-ap) of 1 V or less, higher voltages are used in some tests that could lead to the generation of free chlorine species (FCS), from chloride ions, and hydroxyl radicals. To examine the impact of high Eap on bioanodes, MECs were acclimated at E-ap = 1 V, tested for one cycle at an Eap of 3 or 4 V until the same total coulombs were achieved as Eap = 1 V, and then returned to cycles of E-ap = 1 V. All biotic MECs with chloride ions showed severe biofilm damage based on the absence of current production, lack of acetate oxidation, and the absence of hydrogen gas production in subsequent cycles at 1 V. Abiotic tests conducted at Eap = 4 V, with same amount of total coulombs transferred as that which occurred in biotic tests at E-ap = 4 V, showed 1.8-fold higher acetate removal than biotic cells at 4 V, suggesting 43% of generated coulombs could have contributed to microbial inactivation. FCS generation, rather than hydroxyl radical production, was concluded to be the major contribution to oxidation of organics due to small changes in acetate oxidation in the presence of a hydroxyl radical scavenger, and the measurement of FCS. These results demonstrated that high applied voltages should be avoided if bioanodes are needed in bioelectrochemical systems when chloride species are present in the solution.
引用
收藏
页数:9
相关论文
共 45 条
[1]  
Alhraishawi A., 2018, J PHYS C SER IOP PUB
[2]   Bioelectrochemical hydrogen production from urban wastewater on a pilot scale [J].
Baeza, Juan A. ;
Martinez-Miro, Alex ;
Guerrero, Javier ;
Ruiz, Yolanda ;
Guisasola, Albert .
JOURNAL OF POWER SOURCES, 2017, 356 :500-509
[3]   What is the efficiency of electro-generation of chlorine with a solid polymer electrolyte assembly? [J].
Bakheet, Belal ;
Beardall, John ;
Zhang, Xiwang ;
McCarthy, David .
CHEMICAL ENGINEERING JOURNAL, 2019, 364 :370-375
[4]  
Bensalah N, 2013, J ADV OXID TECHNOL, V16, P9
[5]   Hydrogen production in a single chamber microbial electrolysis cell lacking a membrane [J].
Call, Douglas ;
Logan, Bruce E. .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2008, 42 (09) :3401-3406
[6]   A method for high throughput bioelectrochemical research based on small scale microbial electrolysis cells [J].
Call, Douglas F. ;
Logan, Bruce E. .
BIOSENSORS & BIOELECTRONICS, 2011, 26 (11) :4526-4531
[7]   Hydrogen Production by Geobacter Species and a Mixed Consortium in a Microbial Electrolysis Cell [J].
Call, Douglas F. ;
Wagner, Rachel C. ;
Logan, Bruce E. .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2009, 75 (24) :7579-7587
[8]   High hydrogen production rate of microbial electrolysis cell (MEC) with reduced electrode spacing [J].
Cheng, Shaoan ;
Logan, Bruce E. .
BIORESOURCE TECHNOLOGY, 2011, 102 (03) :3571-3574
[9]   Monitoring the speciation of aqueous free chlorine from pH 1 to 12 with Raman spectroscopy to determine the identity of the potent low-pH oxidant [J].
Cherney, Daniel P. ;
Duirk, Stephen E. ;
Tarr, James C. ;
Collette, Timothy W. .
APPLIED SPECTROSCOPY, 2006, 60 (07) :764-772
[10]   Degradation of organic compounds in wastewater matrix by electrochemically generated reactive chlorine species: Kinetics and selectivity [J].
Chung, Chong Min ;
Hong, Seok Won ;
Cho, Kangwoo ;
Hoffmann, Michael R. .
CATALYSIS TODAY, 2018, 313 :189-195