A highly selective membrane electrodes based on a two newly synthesized nickel (II) Schiff bases, [NiL1] and [NiL2] where L-1 and L-2 are N,N/bis(salicylaldehyde)4,5-dimethyl-1,2-phenylenediamine (H2L1) and N,N/bis(salicylaldehyde)4,5-dichloro-1,2-phenylenediamine (H2L2) were used as a neutral carrier ionophores for static and hydrodynamic potentiometric mode of operations for the determination of periodate. Under static mode of operation, the sensors displayed a near-Nernstian slope of -66.1 +/- 0.8 and -59.9 +/- 1.1 mV decade(-1) of activity and detection limits to 5.2 x 10(-6) and 7.3 x 10(-6) mol L-1 for the sensors based on [NiL1] and [NiL2], respectively. Under hydrodynamic mode of operation (FIA), the slope of the calibration plot, limit of detection, and working linear range were -71.1 mVdecade(-1) of activity, 7.3 x 10(-6) and 1.0 x 10(-5) to 1.0 x 10(-3) mol L-1, respectively. The response time of the sensors in whole concentration ranges was very short (< 10 s). The response of the sensors was independent on the pH range of 3-8. A tubular version was further developed and coupled to a flow injection system for ascorbic acid (AA) determination in beverages and pharmaceutical preparations. This approach was achieved by selecting a 50-cm reactor and an overall flow of 3 mL min(-1), and injecting volume 100 mu L of AA standards in a 1.0 x 10(-4) mol L-1 IO4- solution. Under these conditions, a linearity range of 2-13 mu g mL(-1), with a slope of 4.97 mV (mg/L)(-1) (r(2) = 0.9995), detection limit 0.9 mg L-1 and a reproducibility of +/- 1.1 mV (n = 5) was recorded. This simple and inexpensive flow injection analysis manifold, with a good potentiometric detector, enabled the analysis of similar to 50 samples h(-1) without requiring pretreatment procedures. An average recovery of 98.8% and a mean standard deviation of 1.3% were obtained. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:1356 / 1363
页数:8
相关论文
共 38 条
[1]   Cationic or anionic sites?: Selectivity optimization of ion-selective electrodes based on charged ionophores [J].
Amemiya, S ;
Bühlmann, P ;
Pretsch, E ;
Rusterholz, B ;
Umezawa, Y .
ANALYTICAL CHEMISTRY, 2000, 72 (07) :1618-1631
[2]  
[Anonymous], 1971, Infrared and Raman Spectra of Inorganic and Coordination Compounds
[3]   ANION-SELECTIVE MEMBRANE ELECTRODES BASED ON METALLOPORPHYRINS - THE INFLUENCE OF LIPOPHILIC ANIONIC AND CATIONIC SITES ON POTENTIOMETRIC SELECTIVITY [J].
BAKKER, E ;
MALINOWSKA, E ;
SCHILLER, RD ;
MEYERHOFF, ME .
TALANTA, 1994, 41 (06) :881-890
[4]   Environmentally friendly LC for the simultaneous determination of ascorbic acid and its derivatives in skin-whitening cosmetics [J].
Balaguer, Angel ;
Chisvert, Alberto ;
Salvador, Arnparo .
JOURNAL OF SEPARATION SCIENCE, 2008, 31 (02) :229-236
[5]   THE PECKING ORDER OF FREE-RADICALS AND ANTIOXIDANTS - LIPID-PEROXIDATION, ALPHA-TOCOPHEROL, AND ASCORBATE [J].
BUETTNER, GR .
ARCHIVES OF BIOCHEMISTRY AND BIOPHYSICS, 1993, 300 (02) :535-543
[6]  
Davey MW, 2000, J SCI FOOD AGR, V80, P825, DOI 10.1002/(SICI)1097-0010(20000515)80:7<825::AID-JSFA598>3.0.CO
[7]  
2-6
[8]   KINETIC IDENTIFICATION AND DETERMINATION OF CERTAIN CARBOHYDRATES WITH A PERIODATE-SENSITIVE PERCHLORATE-SELECTIVE ELECTRODE [J].
EFSTATHIOU, CE ;
HADJIIOANNOU, TP .
ANALYTICA CHIMICA ACTA, 1977, 89 (01) :55-63
[9]   USE OF A PERIODATE-SENSITIVE PERCHLORATE ION-SELECTIVE ELECTRODE IN KINETIC ULTRAMICRODETERMINATION OF MANGANESE(II) BY MEANS OF ITS CATALYTIC EFFECT ON PERIODATE-ACETYLACETONE REACTION [J].
EFSTATHIOU, CE ;
HADJIOANNOU, TP .
TALANTA, 1977, 24 (04) :270-272
[10]   SELECTIVITY-MODIFYING INFLUENCE OF ANIONIC SITES IN NEUTRAL-CARRIER-BASED MEMBRANE ELECTRODES [J].
EUGSTER, R ;
GEHRIG, PM ;
MORF, WE ;
SPICHIGER, UE ;
SIMON, W .
ANALYTICAL CHEMISTRY, 1991, 63 (20) :2285-2289