Technical Note: Comparison of the wavefront aberrations between natural and pharmacological pupil dilations

被引:15
作者
Yang, Yabo [1 ]
Wu, Fang [1 ]
机构
[1] Zhejiang Univ, Dept Ophthalmol, Second Hosp, Hangzhou 310027, Peoples R China
关键词
cycloplegic; pupil diameter; pupil dilation; scotopic; wavefront aberration;
D O I
10.1111/j.1475-1313.2006.00461.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Ocular wavefront aberrations were tested with the wavefront-supported corneal ablation (WASCA) aberrometer when the pupil was dilated naturally under scotopic illumination levels, and pharmacologically using tropicamide. Wavefront aberrations were measured across a 5-mm pupil in one eye of each of 58 subjects. There was a significant difference in the pupil diameter between the scotopic and cycloplegic conditions (p < 0.001). For higher order aberrations (HOAs), no significant difference was found in Zernike coefficients between the scotopic and cycloplegic conditions. There was no significant difference in the spherical equivalent refraction. Accommodation can be neglected during the wavefront aberration measurement with the WASCA aberrometer. In view of the shift of the pupil centre caused by pharmacological pupil dilation, obtaining measurements under natural conditions rather than using mydriatics is recommended for customized laser in situ keratomileusis (LASIK) surgery.
引用
收藏
页码:220 / 223
页数:4
相关论文
共 21 条
[1]  
[Anonymous], WAVEFRONT CUSTOMIZED
[2]   Optics of aberroscopy and super vision [J].
Applegate, RA ;
Thibos, LN ;
Hilmantel, G .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (07) :1093-1107
[3]   Optical modulation transfer and contrast sensitivity with decentered small pupils in the human eye [J].
Artal, P ;
Marcos, S ;
Iglesias, I ;
Green, DG .
VISION RESEARCH, 1996, 36 (22) :3575-3586
[4]   Accommodation and acuity under night-driving illumination levels [J].
Arumi, P ;
Chauhan, K ;
Charman, WN .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1997, 17 (04) :291-299
[5]  
Carkeet A, 2003, J REFRACT SURG, V19, P316
[6]   Study on the effects of monochromatic aberrations in the accommodation response by using adaptive optics [J].
Fernández, EJ ;
Artal, P .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2005, 22 (09) :1732-1738
[7]   Aberrometry due dilated pupils - Which mydriatic should be used? [J].
Giessler, S ;
Hammer, T ;
Duncker, GIW .
KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2002, 219 (09) :655-659
[8]   Measurement of the wave-front aberration of the eye by a fast psychophysical procedure [J].
He, JC ;
Marcos, S ;
Webb, RH ;
Burns, SA .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1998, 15 (09) :2449-2456
[9]   Monochromatic aberrations in the accommodated human eye [J].
He, JC ;
Burns, SA ;
Marcos, S .
VISION RESEARCH, 2000, 40 (01) :41-48
[10]  
LEIBOWITZ HW, 1978, DOC OPHTHALMOL, V46, P133