A compact time-to-amplitude converter for single-photon time-of-flight measurement

被引:4
|
作者
Ma, Zhiqiang [1 ,2 ]
Xu, Yue [1 ,2 ,3 ]
Zhu, Sihui [1 ,2 ]
Wu, Zhong [1 ,2 ]
机构
[1] Nanjing Univ Posts & Telecommun, Coll Elect & Opt Engn, Nanjing 210023, Peoples R China
[2] Nanjing Univ Posts & Telecommun, Coll Microelect, Nanjing 210023, Peoples R China
[3] Nanjing Univ Posts & Telecommun, Natl & Local Joint Engn Lab RF Integrat & Microas, Nanjing 210023, Peoples R China
基金
中国国家自然科学基金;
关键词
Single-photon avalanche diode (SPAD); time-of-flight (TOF); time-to-amplitude converter (TAC); power consumption;
D O I
10.1080/09500340.2021.1912425
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
This work proposes a compact time-to-amplitude converter (TAC) for single-photon time-of-flight (TOF) measurement. Based on the principle of current mirror integration, the regulated cascode output structure is used to improve the integration linearity. Fabricated in 180 nm standard CMOS technology, the test results show that the proposed TAC achieves an integral nonlinearity of less than 1.1 LSB, and a timing resolution of 78 ps in a full-scale range (FSR) of 20 ns. Moreover, the readout voltage only varies by 1% during 1 ms hold-off time. The simple circuit structure make TAC occupy a small area of 120 mu m(2) and consume low dynamic power of 36.8 mu W. The TOF measurement error is less than 5.2 cm, and the measurement precision is up to 1.61 cm at 150 cm. The presented TAC provides a compact implementation solution to realize high-density TOF sensors.
引用
收藏
页码:463 / 470
页数:8
相关论文
共 50 条
  • [31] Monolithic Single-Photon detectors and Time-to-Digital Converters for picoseconds Time-of-Flight ranging
    Markovic, Bojan
    Tisa, Simone
    Tosi, Alberto
    Zappa, Franco
    SENSORS, CAMERAS, AND SYSTEMS FOR INDUSTRIAL, SCIENTIFIC, AND CONSUMER APPLICATIONS XII, 2011, 7875
  • [32] SPAD Smart Pixel for Time-of-Flight and Time-Correlated Single-Photon Counting Measurements
    Villa, F.
    Markovic, B.
    Bellisai, S.
    Bronzi, D.
    Tosi, A.
    Zappa, F.
    Tisa, S.
    Durini, D.
    Weyers, S.
    Paschen, U.
    Brockherde, W.
    IEEE PHOTONICS JOURNAL, 2012, 4 (03): : 795 - 804
  • [33] Time-of-flight optical ranging system based on time-correlated single-photon counting
    Massa, JS
    Buller, GS
    Walker, AC
    Cova, S
    Umasuthan, M
    Wallace, AM
    APPLIED OPTICS, 1998, 37 (31): : 7298 - 7304
  • [34] A Review of Single-Photon Avalanche Diode Time-of-Flight Imaging Sensor Arrays
    Piron, Francois
    Morrison, Daniel
    Yuce, Mehmet Rasit
    Redoute, Jean-Michel
    IEEE SENSORS JOURNAL, 2021, 21 (11) : 12654 - 12666
  • [35] Human activity recognition using a single-photon direct time-of-flight sensor
    Mora-Martin, German
    Scholes, Stirling
    Henderson, Robert K.
    Leach, Jonathan
    Gyongy, Istvan
    OPTICS EXPRESS, 2024, 32 (10): : 16645 - 16656
  • [36] Illuminating Depth: Polarimetric Time-of-Flight Sensing with Single-Photon Counting Imager
    Schnier, Karsten
    Swakshar, Anirban
    Coldwell, Cooper
    Gurbuz, Sevgi
    Kim, Seongsin M.
    Kung, Patrick
    POLARIZATION: MEASUREMENT, ANALYSIS, AND REMOTE SENSING XVI, 2024, 13050
  • [37] WIDE-BAND TIME-TO-AMPLITUDE CONVERTER
    BUDYASHO.YG
    ZINOV, VG
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1968, (04): : 868 - &
  • [38] A TIME-TO-AMPLITUDE CONVERTER FOR USE WITH A PULSED ACCELERATOR
    MAYDAN, D
    NUCLEAR INSTRUMENTS & METHODS, 1965, 34 (02): : 229 - &
  • [39] EXPERIMENTAL CHECK OF A THEORY OF TIME-TO-AMPLITUDE CONVERTER
    FARACI, G
    PENNISI, AR
    LETTERE AL NUOVO CIMENTO, 1981, 31 (04): : 121 - 124
  • [40] PRECISE CALIBRATION METHOD FOR TIME-TO-AMPLITUDE CONVERTER
    LITTMAN, MG
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1974, 45 (12): : 1608 - 1609