Electrocatalytic Oxidation of Folic Acid on Carbon Paste Electrode Modified by Nickel Ions Dispersed into Poly(o-anisidine) Film

被引:41
作者
Ojani, Reza [1 ]
Raoof, Jahan-Bakhsh [1 ]
Zamani, Saeed [1 ]
机构
[1] Mazandaran Univ, Electroanalyt Chem Res Lab, Fac Chem, Babol Sar, Iran
关键词
Carbon paste electrode; ortho-Anisidine; Electropolymerization; Sodium dodecyl sulfate (SDS); Folic acid; Electrocatalytic oxidation; Nickel; Thin films; LIQUID-CHROMATOGRAPHIC DETERMINATION; AMINO-ACIDS; POLAROGRAPHIC-DETERMINATION; ELECTROPOLYMERIZATION; METHANOL; COPPER;
D O I
10.1002/elan.200904673
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Poly(o-anisidine) (POA) was formed by successive cyclic voltammetry in monomer solution containing sodium dodecyl sulfate (SDS) at the surface of carbon paste electrode. Then Ni(II) ions were incorporated to electrode by immersion of the polymeric modified electrode having amine group in 0.1 M Ni(II) ion solution. Cyclic voltammetric and chronoamperometric experiments were used for the electrochemical study of this modified electrodes a good redox behavior of Ni(OH)(2)/NiOOH couple at the surface of electrode can be observed, The capability of this modified electrode for catalytic oxidation of folic acid was demonstrated. The amount of a and Surface coverage (I*) of the redox species and catalytic chemical reaction rate constant (k) for folic acid oxidation were calculated. The catalytic oxidation peak current of folic acid was linearly dependent on its concentration and a linear calibration curve was obtained in the range of 0.1 to 5 mM with a correlation coefficient of 0.9994. The limit of detection (3 sigma) was determined as 0.091 mM. This electrocatalytic oxidation was used as simple, selective and precise voltammetric method for determination of folic acid in pharmaceutical preparations.
引用
收藏
页码:2634 / 2639
页数:6
相关论文
共 29 条
[1]  
Akhtar P, 1997, ANAL CHIM ACTA, V339, P201, DOI 10.1016/S0003-2670(96)00477-1
[2]   Poly(o-anisidine)-anion composite films as sensing platform for biological molecules [J].
Angaleeswari, B. ;
Amirtham, R. M. Dura ;
Jeevithaa, I. ;
Vaishnavi, V. ;
Eevera, T. ;
Berchmans, Sheela ;
Yegnaramar, V. .
SENSORS AND ACTUATORS B-CHEMICAL, 2008, 129 (02) :558-565
[3]  
Bard A. J., 2001, ELECTROCHEMICAL METH
[4]   Copper dispersed into polyaniline films as an amperometric sensor in alkaline solutions of amino acids and polyhydric compounds [J].
Casella, IG ;
Cataldi, TRI ;
Guerrieri, A ;
Desimoni, E .
ANALYTICA CHIMICA ACTA, 1996, 335 (03) :217-225
[5]  
DONG MW, 1988, J CHROMATOGR, V442, P81, DOI 10.1016/S0021-9673(00)94458-3
[6]  
Eramo F. D., 1999, ELECTROANAL, V11, P481
[7]  
GAO M, 2000, J INSTRU ANAL, V19, P9
[8]   Electrocatalytic oxidation of methanol on a nickel-porphyrin IX complex modified glassy carbon electrode in alkaline medium [J].
Golabi, SM ;
Nozad, A .
ELECTROANALYSIS, 2004, 16 (03) :199-209
[9]   Electrocatalytic oxidation and determination of deferasirox and deferiprone on a nickel oxyhydroxide-modified electrode [J].
Hajjizadeh, M. ;
Jabbari, A. ;
Heli, H. ;
Moosavi-Movahedi, A. A. ;
Shafiee, A. ;
Karimian, K. .
ANALYTICAL BIOCHEMISTRY, 2008, 373 (02) :337-348
[10]   POLAROGRAPHIC-DETERMINATION OF FOLIC-ACID IN PHARMACEUTICAL PREPARATIONS [J].
JACOBSEN, E ;
WIESEBJORNSEN, M .
ANALYTICA CHIMICA ACTA, 1978, 96 (02) :345-351