Distal lower extremity imaging: Prospective comparison of 2-dimensional time of flight, 3-dimensional time-resolved contrast-enhanced magnetic resonance angiography, and 3-dimensional bolus chase contrast-enhanced magnetic resonance angiography

被引:16
作者
Hahn, Winnie Y.
Hecht, Elizabeth M.
Friedman, Barak
Babb, James S.
Jacobowitz, Glenn R.
Lee, Vivian S.
机构
[1] Georgetown Univ Hosp, Dept Radiol, Washington, DC 20007 USA
[2] NYU, Med Ctr, Dept Radiol, New York, NY 10016 USA
[3] Northshore Long Isl Jewish Med Ctr, Dept Radiol, New Hyde Pk, NY USA
[4] NYU, Med Ctr, Dept Vasc Surg, New York, NY 10016 USA
关键词
magnetic resonance imaging; atherosclerosis; peripheral artery imaging; magnetic resonance angiography; time-resolved; bolus chase; time of flight;
D O I
10.1097/01.rct.0000235073.72926.4d
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To compare the 2-dimensional time of flight, the 3-dimensional time-resolved contrast-enhanced magnetic resonance (MR) angiography, and the 3-dimensional 3-station bolus chase contrast-enhanced MR angiography in assessing distal station atherosclerosis. Methods: Two-dimensional time of flight, 3-dimensional time-resolved contrast-enhanced MR angiography, and 3-dimensional bolus chase contrast-enhanced MR angiography were performed from the knees to the metatarsal heads of 40 patients. Blinded to the patients' identity, 2 readers independently reviewed the 3 sequences in random order; differences were resolved by consensus. Anterior tibial, peroneal, and posterior tibial arterial lengths to the talar dome were scored as follows: 1, greater than 50% of the length of a normal artery; 2, less than 50%; and 3, total occlusion. Stenoses were scored as follows: 1, less than 50%; and 2, greater than 50%. The pedal vessels (dorsalis pedis, posterior tibial, and plantar pedal arch arteries) were scored as follows: 1, less than 50% stenosis; and 21 greater than 50% stenosis. The reference standard was a combined interpretation of all 3 sequences by both readers in consensus. Results: For the 240 calf segments scored for length, concordance with reference assessment was poorer for the time of flight than for either the bolus chase or time-resolved angiography (P = 0.0021 and P = 0.0082, respectively), and the latter two were statistically indistinguishable. For stenosis grading of the 461 calf and pedal segments, the time-resolved and bolus chase methods were superior to the time of flight (P = < 0.0001 and P = 0.0041, respectively), and the contrast-enhanced methods were statistically indistinguishable. Conclusions: Both contrast-enhanced time-resolved and bolus chase MR angiography are superior to the time of flight in diagnosing distal station peripheral vascular disease.
引用
收藏
页码:29 / 36
页数:8
相关论文
共 25 条
[1]   MAGNETIC-RESONANCE ANGIOGRAPHY AND MEASUREMENT OF BLOOD-FLOW IN THE PERIPHERAL VESSELS [J].
CAPUTO, GR ;
HIGGINS, CB .
INVESTIGATIVE RADIOLOGY, 1992, 27 :S97-S102
[2]   Breath-hold single-dose gadolinium-enhanced three-dimensional MR aortography: Usefulness of a timing examination and MR power injector [J].
Earls, JP ;
Rofsky, NM ;
DeCorato, DR ;
Krinsky, GA ;
Weinreb, JC .
RADIOLOGY, 1996, 201 (03) :705-710
[3]  
Fink C, 2005, INVEST RADIOL, V40, P40
[4]   Optimization of contrast timing for breath-hold three-dimensional MR angiography [J].
Hany, TF ;
McKinnon, GC ;
Leung, DA ;
Pfammatter, T ;
Debatin, JF .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (03) :551-556
[5]  
HO KY, 1998, RADIOLOGY, V206, P592
[6]   Time-resolved contrast-enhanced 3D MR angiography [J].
Korosec, FR ;
Frayne, R ;
Grist, TM ;
Mistretta, CA .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (03) :345-351
[7]   Diabetes and peripheral arterial occlusive disease:: Prospective comparison of contrast-enhanced three-dimensional MR angiography with conventional digital subtraction angiography [J].
Kreitner, KF ;
Kalden, P ;
Neufang, A ;
Düber, C ;
Krummenauer, F ;
Küstner, E ;
Laub, G ;
Thelen, M .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (01) :171-179
[8]   Distal lower extremity arteries: Evaluation with two-dimensional MR digital subtraction angiography [J].
Lee, HM ;
Wang, Y ;
Sostman, HD ;
Schwartz, LH ;
Khilnani, NM ;
Trost, DW ;
de Arellano, ER ;
Teeger, S ;
Bush, HL .
RADIOLOGY, 1998, 207 (02) :505-512
[9]  
Li W, 2000, J MAGN RESON IMAGING, V12, P884, DOI 10.1002/1522-2586(200012)12:6<884::AID-JMRI11>3.0.CO
[10]  
2-C