Low-temperature Conductivity Detection for Ultrasensitive Ion Chromatography

被引:2
作者
Eom, Jiwon [1 ]
Lee, Dong Soo [1 ]
机构
[1] Yonsei Univ, Dept Chem, Seoul 120749, South Korea
关键词
Low-temperature; Conductivity detection; Ion chromatography; Nonlinear response; Calibration sensitivity; SUPPRESSION;
D O I
10.1002/bkcs.10673
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The effects of conductivity detection temperature on calibration sensitivity and linearity in suppressed ion chromatography using hydronium or hydroxide eluent were investigated. Theoretical calibration curves for lithium and nitrate ions at 0-35 degrees C were calculated and compared with experimental data. As the detection temperature was lowered, both sensitivity and linearity of calibration at low concentrations were improved due to the reduced interference by water autoionization equilibrium; 4.3- and 1.3-fold increases in linear regression slopes were observed in the 0-1 mu mol/L range when the temperature was lowered from 35 to 5 degrees C for lithium and nitrate, respectively, along with significant increases in the correlation coefficient. Any remaining water autoionization effect was near completely removed by using eluents contaminated with rubidium or bromide ion at 0.1 mu mol/L.
引用
收藏
页码:321 / 329
页数:9
相关论文
共 11 条
[1]   Two-dimensional detection in ion chromatography: Sequential conductometry after suppression and passive hydroxide introduction [J].
Al-Horr, R ;
Dasgupta, PK ;
Adams, RL .
ANALYTICAL CHEMISTRY, 2001, 73 (19) :4694-4703
[2]  
Bartsch H. J., 1990, TASCHENBUCH MATH FOR, P420
[3]   Non-linear calibration functions in ion chromatography with suppressed conductivity detection using hydroxide eluents [J].
Brinkmann, T ;
Specht, CH ;
Frimmel, FH .
JOURNAL OF CHROMATOGRAPHY A, 2002, 957 (02) :99-109
[4]  
CASSIDY R, 1992, LC GC-MAG SEP SCI, V10, P692
[5]   Development of an automated method for simultaneous determination of low molecular weight aliphatic amines and ammonia in ambient air by diffusion scrubber coupled to ion chromatography [J].
Chang, IH ;
Lee, CG ;
Lee, DS .
ANALYTICAL CHEMISTRY, 2003, 75 (22) :6141-6146
[6]   THEORETICAL APPROACH OF DUAL-COLUMN ION CHROMATOGRAPHY [J].
DOURYBERTHOD, M ;
GIAMPAOLI, P ;
PITSCH, H ;
SELLA, C ;
POITRENAUD, C .
ANALYTICAL CHEMISTRY, 1985, 57 (12) :2257-2263
[7]   Lower Limits and Nonlinearity of Calibration in Suppressed Ion Chromatography with Strong Acid Eluent [J].
Eom, Jiwon ;
Kim, Mi-Young ;
Lee, Bokyoung ;
Lee, Dong Soo .
BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2015, 36 (08) :2073-2080
[8]   The fundamental conductivity and resistivity of water [J].
Light, TS ;
Licht, S ;
Bevilacqua, AC ;
Morash, KR .
ELECTROCHEMICAL AND SOLID STATE LETTERS, 2005, 8 (01) :E16-E19
[9]   Calculating the conductivity of natural waters [J].
Pawlowicz, Rich .
LIMNOLOGY AND OCEANOGRAPHY-METHODS, 2008, 6 :489-501
[10]  
Small H., 1989, ION CHROMATOGRAPHY, P175