Quantitative analysis of template-based attenuation compensation in 3D brain PET

被引:15
|
作者
Montandon, Marie-Louise [1 ]
Zaidi, Habib [1 ]
机构
[1] Univ Hosp Geneva, Div Nucl Med, CH-1211 Geneva 4, Switzerland
关键词
PET; attenuation correction; brain imaging; template; quantitative analysis;
D O I
10.1016/j.compmedimag.2006.09.017
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An atlas-guided attenuation correction method was recently proposed for 3D brain positron emission tomography (PET) imaging eliminating the need for acquisition of a patient-specific measured transmission scan. The algorithm was validated through comparison to transmission-based attenuation correction (gold standard) using voxelwise statistical parametric mapping (SPM) analysis of clinical data. In contrast to brain 'activation' studies for which SPM is primarily developed, brain PET research studies often involve absolute quantification. In the preliminary validation study published earlier, there is no validation as to how such quantification can be affected by the two methods as the assessment was carried out by an SPM group analysis alone. It is quite important to demonstrate how the proposed method performs individually, particularly for diagnostic applications or individual quantification. In this study, we assess the quantitative accuracy of this method in clinical setting using automated volume of interest (VOI)-based analysis by means of the commercially available BRASS software. There is a very good correlation (R-2 = 0.91) between the atlas-guided and measured transmission-guided attenuation correction techniques and the regression line agreed well with the line of identity (slope = 0.96) for the grouped analysis of patient data. The mean relative difference between the two methods for all VOIs across the whole population is 2.3% whereas the maximum difference is less than 7%. No proof of statistically significant differences could be verified for all regions. These encouraging results provide further confidence in the adequacy of the proposed approach demonstrating its performance particularly for research studies or diagnostic applications involving quantification. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:28 / 38
页数:11
相关论文
共 50 条
  • [31] MRI-based attenuation correction for brain PET/MRI based on anatomic signature and machine learning
    Yang, Xiaofeng
    Wang, Tonghe
    Lei, Yang
    Higgins, Kristin
    Liu, Tian
    Shim, Hyunsuk
    Curran, Walter J.
    Mao, Hui
    Nye, Jonathon A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (02):
  • [32] Quantitative Comparison of 3D Freehand Ultrasound and MRI Images of the Neonatal Brain
    Blanchard, Martin
    Martin, Matthieu
    Quetin, Philippe
    Delachartre, Philippe
    PROCEEDINGS OF THE 2020 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2020,
  • [33] An Astrocyte Structural Organization Analysis Based on Fluorescent Microscopy with 2D and 3D Quantitative Approaches
    Nosova O.I.
    Sufieva D.A.
    Korzhevsky D.E.
    Cell and Tissue Biology, 2021, 15 (3) : 273 - 279
  • [34] GPU-based 3D SAFT reconstruction including attenuation correction
    Kretzek, E.
    Hopp, T.
    Ruiter, N. V.
    MEDICAL IMAGING 2015: ULTRASONIC IMAGING AND TOMOGRAPHY, 2015, 9419
  • [35] Software development for quantitative analysis of brain amyloid PET
    Matsuda, Hiroshi
    Yamao, Tensho
    BRAIN AND BEHAVIOR, 2022, 12 (03):
  • [36] MR-based attenuation correction in brain PET based on UTE sequences
    Jorge Cabello
    Stephan G Nekolla
    Sibylle I Ziegler
    EJNMMI Physics, 1 (Suppl 1)
  • [37] Influence and Compensation of Truncation Artifacts in MR-Based Attenuation Correction in PET/MR
    Schramm, G.
    Langner, J.
    Hofheinz, F.
    Petr, J.
    Lougovski, A.
    Beuthien-Baumann, B.
    Platzek, I.
    van den Hoff, J.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2013, 32 (11) : 2056 - 2063
  • [38] Investigation of MR-Based Attenuation Correction and Motion Compensation for Hybrid PET/MR
    Buerger, Christian
    Tsoumpas, Charalampos
    Aitken, Andrew
    King, Andrew Peter
    Schleyer, Paul
    Schulz, Volkmar
    Marsden, Paul K.
    Schaeffter, Tobias
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (05) : 1967 - 1976
  • [39] Evaluation of a 2D UNet-Based Attenuation Correction Methodology for PET/MR Brain Studies
    Presotto, Luca
    Bettinardi, Valentino
    Bagnalasta, Matteo
    Scifo, Paola
    Savi, Annarita
    Vanoli, Emilia Giovanna
    Fallanca, Federico
    Picchio, Maria
    Perani, Daniela
    Gianolli, Luigi
    De Bernardi, Elisabetta
    JOURNAL OF DIGITAL IMAGING, 2022, 35 (03) : 432 - 445
  • [40] Joint Reconstruction of Activity and Attenuation in Time-of-Flight PET: A Quantitative Analysis
    Rezaei, Ahmadreza
    Deroose, Christophe M.
    Vahle, Thomas
    Boada, Fernando
    Nuyts, Johan
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59 (10) : 1630 - 1635