Quantitative analysis of template-based attenuation compensation in 3D brain PET

被引:15
|
作者
Montandon, Marie-Louise [1 ]
Zaidi, Habib [1 ]
机构
[1] Univ Hosp Geneva, Div Nucl Med, CH-1211 Geneva 4, Switzerland
关键词
PET; attenuation correction; brain imaging; template; quantitative analysis;
D O I
10.1016/j.compmedimag.2006.09.017
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An atlas-guided attenuation correction method was recently proposed for 3D brain positron emission tomography (PET) imaging eliminating the need for acquisition of a patient-specific measured transmission scan. The algorithm was validated through comparison to transmission-based attenuation correction (gold standard) using voxelwise statistical parametric mapping (SPM) analysis of clinical data. In contrast to brain 'activation' studies for which SPM is primarily developed, brain PET research studies often involve absolute quantification. In the preliminary validation study published earlier, there is no validation as to how such quantification can be affected by the two methods as the assessment was carried out by an SPM group analysis alone. It is quite important to demonstrate how the proposed method performs individually, particularly for diagnostic applications or individual quantification. In this study, we assess the quantitative accuracy of this method in clinical setting using automated volume of interest (VOI)-based analysis by means of the commercially available BRASS software. There is a very good correlation (R-2 = 0.91) between the atlas-guided and measured transmission-guided attenuation correction techniques and the regression line agreed well with the line of identity (slope = 0.96) for the grouped analysis of patient data. The mean relative difference between the two methods for all VOIs across the whole population is 2.3% whereas the maximum difference is less than 7%. No proof of statistically significant differences could be verified for all regions. These encouraging results provide further confidence in the adequacy of the proposed approach demonstrating its performance particularly for research studies or diagnostic applications involving quantification. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:28 / 38
页数:11
相关论文
共 50 条
  • [1] Comparison of Template-Based Versus CT-Based Attenuation Correction for Hybrid MR/PET Scanners
    Kops, Elena Rota
    Hautzel, Hubertus
    Herzog, Hans
    Antoch, Gerald
    Shah, N. Jon
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2015, 62 (05) : 2115 - 2121
  • [2] Attenuation compensation in cerebral 3D PET: effect of the attenuation map on absolute and relative quantitation
    Zaidi, H
    Montandon, ML
    Slosman, DO
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 (01) : 52 - 63
  • [3] Attenuation compensation in cerebral 3D PET: effect of the attenuation map on absolute and relative quantitation
    Habib Zaidi
    Marie-Louise Montandon
    Daniel O. Slosman
    European Journal of Nuclear Medicine and Molecular Imaging, 2004, 31 : 52 - 63
  • [4] Comparison template-based with CT-based attenuation correction for hybrid MR/PET scanners
    Elena Rota Kops
    Hans Herzog
    N Jon Shah
    EJNMMI Physics, 1 (Suppl 1)
  • [5] Template-based method for multiple volumes of interest of human brain PET images
    Yasuno, F
    Hasnine, AH
    Suhara, T
    Ichimiya, T
    Sudo, Y
    Inoue, M
    Takano, A
    Ou, T
    Ando, T
    Toyama, H
    NEUROIMAGE, 2002, 16 (03) : 577 - 586
  • [6] 3D Dental Mesh Repairing Using Template-based Deformation
    Xia, Genyuan
    Chen, Li
    2014 7TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2014), 2014, : 410 - 414
  • [7] Accurate hybrid template-based and MR-based attenuation correction using UTE images for simultaneous PET/MR brain imaging applications
    Baran, Jakub
    Chen, Zhaolin
    Sforazzini, Francesco
    Ferris, Nicholas
    Jamadar, Sharna
    Schmitt, Ben
    Faul, David
    Shah, Nadim Jon
    Cholewa, Marian
    Egan, Gary F.
    BMC MEDICAL IMAGING, 2018, 18
  • [8] Template-based method to measure the 3D joint space for hand arthritis
    Duryea, J
    MEDICAL IMAGING 2005: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2005, 5745 : 781 - 790
  • [9] A template-based reconstruction of plane-symmetric 3D models from freehand sketches
    Cheon, Sang-Uk
    Han, Soonhung
    COMPUTER-AIDED DESIGN, 2008, 40 (09) : 975 - 986
  • [10] Monocular template-based 3D surface reconstruction: Convex inextensible and nonconvex isometric methods
    Brunet, F.
    Bartoli, A.
    Hartley, R. I.
    COMPUTER VISION AND IMAGE UNDERSTANDING, 2014, 125 : 138 - 154