Convective cooling effect on cooled-tip catheter compared to large-tip catheter radiofrequency ablation

被引:18
作者
Pilcher, Thomas A.
Sanford, Anna L.
Saul, J. Philip
Haemmerich, Dieter
机构
[1] Med Univ S Carolina, Div Pediat Cardiol, Charleston, SC 29425 USA
[2] Clemson Univ, Dept Bioengn, Clemson, SC USA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2006年 / 29卷 / 12期
关键词
ablation; convective cooling; lesion size; large-tip catheter; cooled-tip catheter;
D O I
10.1111/j.1540-8159.2006.00549.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Both actively cooled-tip and large-tip catheters are currently available clinically to create large endomyocardial lesions during application of radiofrequency (RF) energy. The purpose of this study was to compare the effect of convective cooling at physiologic flow rates on RF lesion size using both actively cooled and large-tip catheters. Methods. Porcine hearts were sectioned into 72 pieces and placed in a temperature-con trolled saline both (37 degrees C) with varying directed flow rates (0, 1, 2, and 3 L/min). Cooled-tip RF ablation (4 mm tip) was performed for 1 minute on 36 tissue sections with power manually titrated to keep tip temperature below 40 degrees C. Large-tip catheter ablation (10 mm tip) was performed at 65 degrees C target temperature for 1 minute on 36 tissue sections. For each catheter, flow rates were randomized between applications. The tissue pieces were sectioned and measured to determine lesion depth, width, and volume. Results. Lesion dimensions were independent of the flow rate for the cooled-tip catheter (mean volumes: 382.0 +/- 121.6, 419.9 +/- 133.4, 375.9 +/- 169.1, and 346.7 +/- 173.4 mm(3) for 0, 1, 2, and 3 L/min flow rate, respectively, P = 0.78). For the large-tip catheter, lesion size varied significantly with flow, such that higher flow rates produced larger lesions (mean volumes: 120.7 +/- 50.7, 256.5 +/- 97.9, 393.4 +/- 149.9, and 548.9 +/- 157.0 mm(3) for 0, 1, 2, and 3 L/min flow rate respectively, P < 0.001) Conclusion. During RF ablation, blood flow rate significantly affects lesion size for large-tip but not cooled-tip catheters. At low flow rates (0-1 L/min) cooled-tip catheters create larger lesions, while at high flow rates (3 L/min) large-tip catheters create larger lesions.
引用
收藏
页码:1368 / 1374
页数:7
相关论文
共 28 条
  • [1] Catheter tip cooling during radiofrequency ablation of intra-atrial reentry: Effects on power, temperature, and impedance
    Blaufox, AD
    Numan, MT
    Laohakunakorn, P
    Knick, B
    Paul, T
    Saul, JP
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2002, 13 (08) : 783 - 787
  • [2] Catheter ablation of ventricular tachycardia in patients with structural heart disease using cooled radiofrequency energy - Results of a prospective multicenter study
    Calkins, H
    Epstein, A
    Packer, D
    Arria, AM
    Hummel, J
    Gilligan, DM
    Trusso, J
    Carlson, M
    Luceri, R
    Kopelman, H
    Wilber, D
    Wharton, JM
    Stevenson, W
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (07) : 1905 - 1914
  • [3] Flow effect on lesion formation in RF cardiac catheter ablation
    Cao, H
    Vorperian, VR
    Tungjitkusolmun, S
    Tsai, JZ
    Haemmerich, D
    Bin Choy, Y
    Webster, JG
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2001, 48 (04) : 425 - 433
  • [4] ENDOCARDIAL MAPPING OF VENTRICULAR-TACHYCARDIA IN THE INTACT HUMAN HEART .2. EVIDENCE FOR MULTIUSE REENTRY IN A FUNCTIONAL SHEET OF SURVIVING MYOCARDIUM
    DOWNAR, E
    KIMBER, S
    HARRIS, L
    MICKLEBOROUGH, L
    SEVAPTSIDIS, E
    MASSE, S
    CHEN, TCK
    GENGA, A
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (04) : 869 - 878
  • [5] Radiofrequency catheter ablation of type 1 atrial flutter using large-tip 8-or 10-mm electrode catheters and a high-output radiofrequency energy generator - Results of a multicenter safety and efficacy study
    Feld, G
    Wharton, M
    Plumb, V
    Daoud, E
    Friehling, T
    Epstein, L
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (08) : 1466 - 1472
  • [6] FOSTER KR, 1989, CRIT REV BIOMED ENG, V17, P25
  • [7] Interrelation of tissue temperature versus flow velocity in two different kinds of temperature-controlled catheter radiofrequency energy applications
    Gumbrecht, S
    Neuzner, J
    Pitschner, HF
    [J]. JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 1998, 2 (02) : 211 - 219
  • [8] Hepatic radiofrequency ablation with internally cooled probes: Effect of coolant temperature on lesion size
    Haemmerich, D
    Chachati, L
    Wright, AS
    Mahvi, DM
    Lee, FT
    Webster, JG
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2003, 50 (04) : 493 - 500
  • [9] Radiofrequency ablation for common atrial flutter using an 8-mm tip catheter and up to 150W
    Hillock, RJ
    Melton, IC
    Crozier, IG
    [J]. EUROPACE, 2005, 7 (05): : 409 - 412
  • [10] Lesion size estimator of cardiac radiofrequency ablation at different common locations with different tip temperatures
    Lai, YC
    Bin Choy, Y
    Haemmerich, D
    Vorperian, VR
    Webster, JG
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2004, 51 (10) : 1859 - 1864