Non-Contact Early Warning of Shaking Palsy

被引:8
|
作者
Yan, Xiaodong [1 ]
Fan, Dou [1 ]
Ren, Aifeng [1 ]
Zhao, Nan [1 ]
Zhang, Zhiya [1 ]
Haider, Daniyal [1 ]
Khan, Muhammad Bilal [1 ]
Tian, Jie [2 ,3 ]
机构
[1] Xidian Univ, Sch Elect Engn, Xian 710071, Shaanxi, Peoples R China
[2] Xidian Univ, Sch Life Sci & Technol, Xian 710126, Shaanxi, Peoples R China
[3] Chinese Acad Sci, Inst Automat, Beijing 100190, Peoples R China
基金
中国国家自然科学基金; 中国博士后科学基金;
关键词
Parkinsonian gait detection; shaking palsy (SP); principal component analysis (PCA); SVM classification; PARKINSONS-DISEASE; GAIT;
D O I
10.1109/JTEHM.2019.2919065
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Parkinsonian gait is a defining feature of shaking palsy (SP) and it has one of the worse impacts on human healthy life than other SP symptoms. The objective of this work is to propose a Parkinsonian gait detection system based on an S-band perception technique to classify abnormal gait and normal walking. Due to the differences in the Gaits of Parkinson's patients compared with healthy persons, the wireless signals reflect and generates different variations at the receiver that could be used for SP diagnosis and classification. To detect a Parkinsonian gait, we first implement data preprocessing of the original data to obtain clear amplitude and phase information. Then, the feature extraction is carried out by principal component analysis (PCA). Finally, a support vector machine (SVM) classification algorithm is applied on collected data to classify the abnormal gait of SP patients compared with a normal gait. We evaluate the proposed system with different people, and the experimental outcomes show that the Parkinsonian gait detection of this training-based system achieves a high accuracy of above 90%. Moreover, the early warning of SP is achieved in a non-contact manner.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Non-contact dispensing systems
    不详
    FLEISCHWIRTSCHAFT, 2010, 90 (10): : 79 - 79
  • [32] Non-contact ultrasonic techniques
    Green, RE
    ULTRASONICS, 2004, 42 (1-9) : 9 - 16
  • [33] Non-contact infrared thermometers
    Vernon, Gervase
    BRITISH JOURNAL OF GENERAL PRACTICE, 2014, 64 (629): : 615 - 615
  • [34] Non-contact blade gauging
    不详
    MER-MARINE ENGINEERS REVIEW, 2001, : 42 - 42
  • [35] Non-contact temperatures measurement
    Materiales de Construccion, 62 (238):
  • [36] NON-CONTACT APPLANATION TONOMETRY
    DUCREY, N
    GEINOZ, J
    FAGGIONI, R
    OPHTHALMOLOGICA, 1975, 170 (05) : 446 - 449
  • [37] Non-contact ECG monitoring
    Brydon, J
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2002, 13 (04) : 641 - 641
  • [38] Non-contact AFM PREFACE
    Giessibl, Franz J.
    Morita, Seizo
    JOURNAL OF PHYSICS-CONDENSED MATTER, 2012, 24 (08)
  • [39] Overdamped non-contact rectifiers
    Moradian, A.
    Alvand, M.
    INTERNATIONAL JOURNAL OF MODERN PHYSICS B, 2018, 32 (20):
  • [40] The Contact/Non-contact Thimble Haptic device
    Choi, Woohyeok
    Hur, Sungmoon
    Kim, Jaeha
    Oh, Yonghwan
    2015 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS (ICM), 2015, : 150 - 155