Non-Contact Early Warning of Shaking Palsy

被引:8
|
作者
Yan, Xiaodong [1 ]
Fan, Dou [1 ]
Ren, Aifeng [1 ]
Zhao, Nan [1 ]
Zhang, Zhiya [1 ]
Haider, Daniyal [1 ]
Khan, Muhammad Bilal [1 ]
Tian, Jie [2 ,3 ]
机构
[1] Xidian Univ, Sch Elect Engn, Xian 710071, Shaanxi, Peoples R China
[2] Xidian Univ, Sch Life Sci & Technol, Xian 710126, Shaanxi, Peoples R China
[3] Chinese Acad Sci, Inst Automat, Beijing 100190, Peoples R China
基金
中国国家自然科学基金; 中国博士后科学基金;
关键词
Parkinsonian gait detection; shaking palsy (SP); principal component analysis (PCA); SVM classification; PARKINSONS-DISEASE; GAIT;
D O I
10.1109/JTEHM.2019.2919065
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Parkinsonian gait is a defining feature of shaking palsy (SP) and it has one of the worse impacts on human healthy life than other SP symptoms. The objective of this work is to propose a Parkinsonian gait detection system based on an S-band perception technique to classify abnormal gait and normal walking. Due to the differences in the Gaits of Parkinson's patients compared with healthy persons, the wireless signals reflect and generates different variations at the receiver that could be used for SP diagnosis and classification. To detect a Parkinsonian gait, we first implement data preprocessing of the original data to obtain clear amplitude and phase information. Then, the feature extraction is carried out by principal component analysis (PCA). Finally, a support vector machine (SVM) classification algorithm is applied on collected data to classify the abnormal gait of SP patients compared with a normal gait. We evaluate the proposed system with different people, and the experimental outcomes show that the Parkinsonian gait detection of this training-based system achieves a high accuracy of above 90%. Moreover, the early warning of SP is achieved in a non-contact manner.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Adaptive Safety Early Warning Device for Non-contact Measurement of HVDC Electric Field
    Suo, Chunguang
    Sun, Hao
    Zhang, Wenbin
    Zhou, Nianrong
    Chen, Weiren
    ELECTRONICS, 2020, 9 (02)
  • [2] Research on the non-contact early warning of dangerous electric field by overhead transmission lines
    Zhang, Wenbin
    Zhou, Nianrong
    Tang, Lijun
    Qi, Fagui
    Zhao, Lei
    INTEGRATED FERROELECTRICS, 2017, 181 (01) : 141 - 150
  • [3] Research and Experiment on Field Warning Device of Non-contact Type
    Li, Songnong
    Zhou, Qiang
    Hou, Xingzhe
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON MECHATRONICS, MATERIALS, CHEMISTRY AND COMPUTER ENGINEERING 2015 (ICMMCCE 2015), 2015, 39 : 2855 - 2860
  • [4] A new IoT system for non-contact body temperature sensing and warning
    Akgun, Fatma Aydin
    Soyturk, Giray
    Dede, Muhtalip
    SIGMA JOURNAL OF ENGINEERING AND NATURAL SCIENCES-SIGMA MUHENDISLIK VE FEN BILIMLERI DERGISI, 2023, 41 (05): : 892 - 899
  • [5] Non-contact mapping
    Schneider, MAE
    Schmitt, C
    ZEITSCHRIFT FUR KARDIOLOGIE, 2000, 89 : 177 - 185
  • [6] Non-contact NDE
    Palmer, SB
    INSIGHT, 1995, 37 (05) : 366 - 367
  • [7] Non-contact tester
    Murray, Jerry
    Printed Circuit Fabrication, 1999, 22 (02):
  • [8] NON-CONTACT TONOMETER
    不详
    MEDICAL LETTER ON DRUGS AND THERAPEUTICS, 1977, 19 (22): : 91 - 92
  • [9] Non-contact thermometers
    不详
    GAS ENGINEERING & MANAGEMENT, 1997, 37 (07): : 38 - 38
  • [10] Non-contact thermometer
    不详
    CHIMICA OGGI-CHEMISTRY TODAY, 1997, 15 (6-7) : 83 - 83