Femoral head material loss at the head-neck junction in total hip arthroplasty: the effect of head size, stem material and stem offset

被引:8
作者
Valente, Giuseppe [1 ]
Lanting, Brent [1 ]
MacDonald, Steven [1 ]
Teeter, Matthew G. [2 ,3 ]
Van Citters, Douglas [4 ]
Howard, James [1 ]
机构
[1] Western Univ, London Hlth Sci Ctr, Schulich Sch Med & Dent, Div Orthopaed Surg,Dept Surg,Univ Hosp, London, ON, Canada
[2] Western Univ, Schulich Sch Med & Dent, Dept Med Biophys, London, ON, Canada
[3] Lawson Hlth Res Inst, Surg Innovat Program, London, ON, Canada
[4] Dartmouth Coll, Thayer Sch Engn, Hanover, NH 03755 USA
关键词
Corrosion; metal-on-polyethylene; taper; total hip arthroplasty; trunnion; trunnionosis; TAPER JUNCTION; CORROSION; METAL; TRUNNIONOSIS; COMPONENTS; INTERFACE;
D O I
10.1177/1120700018814473
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Material loss at the head-neck junction in total hip arthroplasty may cause adverse clinical symptoms and implant failure. The purpose of this study was to quantitatively examine the effects of head size, stem material and stem offset on material loss of the head-neck taper interface of a single trunnion design in retrieval implants of metal on polyethylene bearing surfaces. Methods: A retrieval study was performed to identify all 28-mm and 32-mm femoral heads from a single implant/taper design implanted for >2 years. This included n = 56 of the 28-mm heads and n = 23 of the 32-mm heads. The 28-mm femoral heads were matched to 32-mm femoral heads based on time in vivo and head length. A coordinate measuring machine was used to determine maximum linear corrosion depth (MLD). Differences in MLD for head diameter, stem material, and stem offset were determined. Results: There were no differences between groups for age, gender, BMI, or implantation time. There was no difference in MLD between 28 mm and 32 mm matched paired head diameters (p = 0.59). There was also no difference in MLD between titanium or cobalt-chromium stems (p = 0.79), and regular or high-offset stems (p = 0.95). Conclusion: There is no statistical difference in femoral head MLD at the head-neck junction in THA between 28-mm and 32-mm matched paired femoral heads, similar or mixed alloy coupled femoral head stem constructs, and regular or high offset stems.
引用
收藏
页码:647 / 651
页数:5
相关论文
共 50 条
[31]   A computational approach to fretting wear prediction at the head-stem taper junction of total hip replacements [J].
English, Russell ;
Ashkanfar, Ariyan ;
Rothwell, Glynn .
WEAR, 2015, 338 :210-220
[32]   Influence of assembly procedure and material combination on the strength of the taper connection at the head-neck junction of modular hip endoprostheses [J].
Rehmer, Annelie ;
Bishop, Nicholas E. ;
Morlock, Michael M. .
CLINICAL BIOMECHANICS, 2012, 27 (01) :77-83
[33]   The effect of altering head length on corrosion using a material loss method [J].
Lanting, Brent A. ;
Wood, Thomas J. ;
Young, Sam ;
Van Citters, Douglas W. ;
MacDonald, Steven J. ;
Howard, James L. ;
Teeter, Matthew G. .
HIP INTERNATIONAL, 2019, 29 (04) :368-372
[34]   Influence of the taper on the fretting wear of the femoral stem-femoral head taper junction in total hip prosthesis [J].
Capitanu, Lucian ;
Badita, Liliana-Laura ;
Tiganesteanu, Constantin ;
Florescu, Virgil .
INDUSTRIAL LUBRICATION AND TRIBOLOGY, 2022, 74 (04) :385-391
[35]   Simultaneous Hip Head-Stem Taper Junction Measurements of Electrochemical Corrosion and Micromotion: A Comparison of Taper Geometry and Stem Material [J].
Swaminathan, V. ;
Scholl, L. ;
Lee, R. ;
Faizan, A. ;
Thakore, M. ;
TenHuisen, K. ;
Nevelos, J. .
MODULARITY AND TAPERS IN TOTAL JOINT REPLACEMENT DEVICES, 2015, 1591 :321-335
[36]   The Relationship Between Cobalt/Chromium Ratios and the High Prevalence of Head-Stem Junction Corrosion in Metal-on-Metal Total Hip Arthroplasty [J].
Hothi, Harry S. ;
Berber, Reshid ;
Whittaker, Robert K. ;
Blunn, Gordon W. ;
Skinner, John A. ;
Hart, Alister J. .
JOURNAL OF ARTHROPLASTY, 2016, 31 (05) :1123-1127
[37]   The association between the sagittal femoral stem alignment and the resulting femoral head centre in total hip arthroplasty [J].
Mueller, Michael ;
Crucius, Dirk ;
Perka, Carsten ;
Tohtz, Stephan .
INTERNATIONAL ORTHOPAEDICS, 2011, 35 (07) :981-987
[38]   Optimal drilling at femoral head-neck junction for treatment of the femoral head necrosis: Experimental and numerical evaluation [J].
Tran, Thanh Ngoc ;
Baltaci, Yeliz ;
Winter, Philipp ;
Tschernig, Thomas ;
Landgraeber, Stefan .
ANNALS OF ANATOMY-ANATOMISCHER ANZEIGER, 2023, 248
[39]   The Influence of Head Size on Corrosion and Fretting Behaviour at the Head-Neck Interface of Artificial Hip Joints [J].
Dyrkacz, Richard M. R. ;
Brandt, Jan-M. ;
Ojo, Olanrewaju A. ;
Turgeon, Thomas R. ;
Wyss, Urs P. .
JOURNAL OF ARTHROPLASTY, 2013, 28 (06) :1036-1040
[40]   Outcome of a modular head-neck adapter system in revision hip arthroplasty [J].
Hoberg, Maik ;
Konrads, Christian ;
Huber, Simon ;
Reppenhagen, Stephan ;
Walcher, Matthias ;
Steinert, Andre ;
Barthel, Thomas ;
Rudert, Maximilian .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2015, 135 (10) :1469-1474