Non-local Means Resolution Enhancement of Lung 4D-CT Data

被引:0
|
作者
Zhang, Yu [1 ,2 ,3 ]
Wu, Guorong [2 ,3 ]
Yap, Pew-Thian [2 ,3 ]
Feng, Qianjin [1 ]
Lian, Jun [4 ]
Chen, Wufan [1 ]
Shen, Dinggang [2 ,3 ]
机构
[1] Southern Med Univ, Sch Biomed Engn, Guang Zhou, Peoples R China
[2] Univ N Carolina, Dept Radiol, Chapel Hill, NC USA
[3] Univ N Carolina, BRIC, Chapel Hill, NC USA
[4] Univ N Carolina, Dept Radiat Oncol, Chapel Hill, NC USA
关键词
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Image resolution in 4D-CT is a crucial bottleneck that needs to be overcome for improved dose planning in radiotherapy for lung cancer. In this paper, we propose a novel patch-based algorithm to enhance the image quality of 4D-CT data. Our premise is that anatomical information missing in one phase can be recovered from complementary information embedded in other phases. We employ a patch-based mechanism to propagate information across phases for reconstruction of intermediate slices in the axial direction, where resolution is normally the lowest. Specifically, structurally-matching and spatially-nearby patches are combined for reconstruction of each patch. For greater sensitivity to anatomical nuances, we further employ a quad-tree technique to adaptively partition each slice of the image in each phase for more fine-grained refinement. Our evaluation based on a public 4D-CT lung data indicates that our algorithm gives very promising results with significantly enhanced image structures.
引用
收藏
页码:214 / 222
页数:9
相关论文
共 50 条
  • [41] 4D Non-Local Means Post-Filtering For Cardiac Gated SPECT
    Song, Chao
    Yang, Yongyi
    Qi, Wenyuan
    Wernick, Miles N.
    Pretorius, P. Hendrik
    King, Michael A.
    2015 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), 2015, : 1200 - 1204
  • [42] 4D non-local means post-filtering for cardiac gated SPECT
    Song, Chao
    Yang, Yongyi
    Pretorius, P. Hendrik
    King, Michael A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (03):
  • [43] Super-resolution reconstruction of 4D-CT lung data via patch-based low-rank matrix reconstruction
    Fang, Shiting
    Wang, Huafeng
    Liu, Yueliang
    Zhang, Minghui
    Yang, Wei
    Feng, Qianjin
    Chen, Wufan
    Zhang, Yu
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (20): : 7925 - 7937
  • [44] Perceptually Motivated Automatic Sharpness Enhancement Using Hierarchy of Non-Local Means
    Choudhury, Anustup
    Medioni, Gerard
    2011 IEEE INTERNATIONAL CONFERENCE ON COMPUTER VISION WORKSHOPS (ICCV WORKSHOPS), 2011,
  • [45] Statistical interpretation of non-local means
    Thacker, N. A.
    Manjon, J. V.
    Bromiley, P. A.
    IET COMPUTER VISION, 2010, 4 (03) : 162 - 172
  • [46] GPU-ACCELERATED NON-LOCAL MEANS SUPER-RESOLUTION RECONSTRUCTION
    Sun, Kongzheng
    Li, Jiade
    Xu, Shuyan
    PROCEEDINGS OF 3RD INTERNATIONAL CONFERENCE ON MULTIMEDIA TECHNOLOGY (ICMT-13), 2013, 84 : 1242 - 1249
  • [47] Image Super-resolution based on Shock Filter and Non-local Means
    Yoshida, Taichi
    Ikehara, Masaaki
    2014 ASIA-PACIFIC SIGNAL AND INFORMATION PROCESSING ASSOCIATION ANNUAL SUMMIT AND CONFERENCE (APSIPA), 2014,
  • [48] Modified Non-Local Means Filtering
    Wahid, Raju G. Farha Fatina
    Shareekhath, K. P.
    2015 IEEE INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING, INFORMATICS, COMMUNICATION AND ENERGY SYSTEMS (SPICES), 2015,
  • [49] Evaluation of Z-Axis Resolution for 4D-CT Scanning Modes
    Klah, P.
    Yanof, J.
    MEDICAL PHYSICS, 2010, 37 (06) : 3144 - +
  • [50] 4D-CT What Is It Good For?
    Meadows, J.
    Wilkinson, M.
    Bichay, T.
    MEDICAL PHYSICS, 2008, 35 (06)