Non-local Means Resolution Enhancement of Lung 4D-CT Data

被引:0
|
作者
Zhang, Yu [1 ,2 ,3 ]
Wu, Guorong [2 ,3 ]
Yap, Pew-Thian [2 ,3 ]
Feng, Qianjin [1 ]
Lian, Jun [4 ]
Chen, Wufan [1 ]
Shen, Dinggang [2 ,3 ]
机构
[1] Southern Med Univ, Sch Biomed Engn, Guang Zhou, Peoples R China
[2] Univ N Carolina, Dept Radiol, Chapel Hill, NC USA
[3] Univ N Carolina, BRIC, Chapel Hill, NC USA
[4] Univ N Carolina, Dept Radiat Oncol, Chapel Hill, NC USA
关键词
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Image resolution in 4D-CT is a crucial bottleneck that needs to be overcome for improved dose planning in radiotherapy for lung cancer. In this paper, we propose a novel patch-based algorithm to enhance the image quality of 4D-CT data. Our premise is that anatomical information missing in one phase can be recovered from complementary information embedded in other phases. We employ a patch-based mechanism to propagate information across phases for reconstruction of intermediate slices in the axial direction, where resolution is normally the lowest. Specifically, structurally-matching and spatially-nearby patches are combined for reconstruction of each patch. For greater sensitivity to anatomical nuances, we further employ a quad-tree technique to adaptively partition each slice of the image in each phase for more fine-grained refinement. Our evaluation based on a public 4D-CT lung data indicates that our algorithm gives very promising results with significantly enhanced image structures.
引用
收藏
页码:214 / 222
页数:9
相关论文
共 50 条
  • [31] Reconstruction and Enhancement of Four-dimensional Cone Beam CT using a Temporal Non-local Means Method
    Jia, X.
    Tian, Z.
    Lou, Y.
    Jiang, S. B.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S58 - S59
  • [32] CT Image Denoising with Non-Local Means Based on Feature Fusion
    Long Chao
    Jin Heng
    Li Ling
    Sheng Jinyin
    Duan Liming
    ACTA OPTICA SINICA, 2022, 42 (11)
  • [33] Fast CT Image Processing using Parallelized Non-local Means
    Wu, Hao
    Zhang, Wenhua
    Gao, Dazhi
    Yin, Xindao
    Chen, Yang
    Wang, Weidong
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2011, 31 (06) : 437 - 441
  • [34] A Fully Automated 4D-CT Registration Algorithm for Lung Studies
    Carnes, G.
    Gaede, S.
    Van Dyk, J.
    Battista, J.
    Lee, T.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [35] Adaptive non-local means filtering based on local noise level for CT denoising
    Li, Zhoubo
    Yu, Lifeng
    Trzasko, Joshua D.
    Fletcher, Joel G.
    McCollough, Cynthia H.
    Manduca, Armando
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [36] Enhancing the resolution of seismic data based on the non-local similarity
    Chen, Siyuan
    Cao, Siyuan
    Sun, Yaoguang
    GEOPHYSICAL PROSPECTING, 2022, 70 (07) : 1116 - 1128
  • [37] DETECTION OF LUNG INJURY USING 4D-CT CHEST IMAGES
    Soliman, Ahmed
    Khalifa, Fahmi
    Shaffie, Ahmed
    Dunlap, Neal
    Wang, Brian
    Elmaghraby, Adel
    El-Baz, Ayman
    2016 IEEE 13TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2016, : 1274 - 1277
  • [38] Multi-phase simultaneous segmentation of tumor in lung 4D-CT data with context information
    Shen, Zhengwen
    Wang, Huafeng
    Xi, Weiwen
    Deng, Xiaogang
    Chen, Jin
    Zhang, Yu
    PLOS ONE, 2017, 12 (06):
  • [39] Reconstruction of Super-Resolution Lung 4D-CT Using Patch-Based Sparse Representation
    Zhang, Yu
    Wu, Guorong
    Yap, Pew-Thian
    Feng, Qianjin
    Lian, Jun
    Chen, Wufan
    Shen, Dinggang
    2012 IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR), 2012, : 925 - 931
  • [40] Variational Optical Flow Estimation Based Super-Resolution Reconstruction for Lung 4D-CT Image
    Geng F.
    Liu H.
    Guo Q.
    Yin Y.
    Jisuanji Yanjiu yu Fazhan/Computer Research and Development, 2017, 54 (08): : 1703 - 1712