Swept source intraoperative OCT angiography

被引:4
作者
Zhang, Ziyi [1 ]
Zhu, Tiepei [2 ]
Cao, Tongtong [1 ]
Gong, Zhaoyu [1 ]
Yao, Lin [1 ]
Liu, Kaiyuan [1 ]
Ye, Juan [2 ]
Li, Peng [1 ,3 ]
机构
[1] Zhejiang Univ, Coll Opt Sci & Engn, State Key Lab Modern Opt Instrumentat, Hangzhou 310027, Zhejiang, Peoples R China
[2] Zhejiang Univ, Eye Ctr, Coll Med, Affiliated Hosp 2, Hangzhou 310003, Zhejiang, Peoples R China
[3] Zhejiang Univ, Int Res Ctr Adv Photon, Hangzhou 310027, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
Biomedical imaging; optical coherence tomography; optical coherence tomography angiography; ophthalmology; deep anterior lamellar keratoplasty; OPTICAL COHERENCE TOMOGRAPHY; DEEP ANTERIOR LAMELLAR; OPHTHALMIC SURGERY; IN-VIVO; KERATOPLASTY; VISUALIZATION; DEPTH;
D O I
10.1142/S1793545821400095
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
To accurately guide surgical instruments during ophthalmic procedures, some necessary intraoperative depth perception is required, which standard surgical microscopes supply limitedly. Intraoperative optical coherence tomography (iOCT), combining optical coherence tomography (OCT) technology and surgical microscope, enables noninvasive, real-time and high-resolution cross-sectional imaging. Currently, though iOCT enables structural imaging, little research has been done on intraoperative angiography. In this work, we presented a swept-source intraoperative OCT angiography (SS-iOCTA) system based on a standard surgical microscope, which provides both structural and angiographic images. The feasibility of the proposed SS-iOCTA was confirmed through deep anterior lamellar keratoplasty (DALK) of ex vivo porcine eyes and blood perfusion imaging of in vivo rat cortex. High-resolution intraoperative feedback, including sub-surface structure and angiogram of biological tissue, can be visualized simultaneously with the SS-iOCTA system, which expand the surgeon's capabilities and could be widely used in clinical surgery.
引用
收藏
页数:9
相关论文
共 50 条
[41]   Feasibility of swept-source OCT for active birdshot chorioretinopathy [J].
Garcia-Garcia, Olga ;
Jordan-Cumplido, Sara ;
Subira-Gonzalez, Olaia ;
Garcia-Bru, Pere ;
Arias, Luis ;
Caminal-Mitjana, Josep M. .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2017, 255 (08) :1493-1502
[42]   Swept-Source OCT for Evaluating the Lamina Cribrosa A Report by the American Academy of Ophthalmology [J].
Takusagawa, Hana L. ;
Hoguet, Ambika ;
Junk, Anna K. ;
Nouri-Mandavi, Kouros ;
Radhakrishnan, Sunita ;
Chen, Teresa C. .
OPHTHALMOLOGY, 2019, 126 (09) :1315-1323
[43]   Depth-encoded all-fiber swept source polarization sensitive OCT [J].
Wang, Zhao ;
Lee, Hsiang-Chieh ;
Ahsen, Osman Oguz ;
Lee, ByungKun ;
Choi, WooJhon ;
Potsaid, Benjamin ;
Liu, Jonathan ;
Jayaraman, Vijaysekhar ;
Cable, Alex ;
Kraus, Martin F. ;
Liang, Kaicheng ;
Hornegger, Joachim ;
Fujimoto, James G. .
BIOMEDICAL OPTICS EXPRESS, 2014, 5 (09) :2931-2949
[44]   Comparative feature analysis in OCT and OCT angiography of diabetic retinopathy [J].
Le, David ;
Son, Taeyoon ;
Lim, Jennifer I. ;
Yao, Xincheng .
OPHTHALMIC TECHNOLOGIES XXXII, 2022, 11941
[45]   Comparison of a commercial spectral-domain OCT and swept-source OCT based on an angiography scan for measuring circumpapillary retinal nerve fibre layer thickness [J].
Tan, Bingyao ;
Chua, Jacqueline ;
Harish, Thiyagrajan ;
Lau, Amanda ;
Gan, Alfred Tau Liang ;
Tan, Yar Li ;
Wong, Damon W. K. ;
Chong, Rachel Shujuan ;
Ang, Marcus ;
Husain, Rahat ;
Schmetterer, Leopold .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2020, 104 (07) :974-979
[46]   Intraoperative Swept-Source OCT-Based Corneal Topography for Measurement and Analysis of Stromal Surface After Epithelial Removal [J].
Zhou, Wen ;
Reinstein, Dan Z. ;
Archer, Timothy J. ;
Chen, Xiangjun ;
Utheim, Tor Paaske ;
Feng, Yue ;
Stojanovic, Aleksandar .
JOURNAL OF REFRACTIVE SURGERY, 2021, 37 (07) :484-+
[47]   112° field of view high-resolution swept-source OCT angiography for rat retinas [J].
Liang, Guangru b. ;
Hormel, Tristan t. ;
Morrison, John c. ;
Lozano, Diana c. ;
Jian, Yifan ;
Campbell, J. peter ;
Jia, Yali .
OPTICS LETTERS, 2024, 49 (22) :6449-6452
[48]   COMPARATIVE ANALYSIS OF OCT AND OCT ANGIOGRAPHY CHARACTERISTICS IN EARLY DIABETIC RETINOPATHY [J].
Le, David ;
Dadzie, Albert ;
Son, Taeyoon ;
Lim, Jennifer I. ;
Yao, Xincheng .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2023, 43 (06) :992-998
[49]   Retinal phantom applicable to OCT, OCT-angiography, and fundus angiography [J].
Lee, Hyunji ;
Lee, Sang-Won ;
Samiudin, Nafra M. ;
Doh, Il .
DESIGN AND QUALITY FOR BIOMEDICAL TECHNOLOGIES XIV, 2021, 11633
[50]   Total retinal blood flow measurement with ultrahigh speed swept source/Fourier domain OCT [J].
Baumann, Bernhard ;
Potsaid, Benjamin ;
Kraus, Martin F. ;
Liu, Jonathan J. ;
Huang, David ;
Hornegger, Joachim ;
Cable, Alex E. ;
Duker, Jay S. ;
Fujimoto, James G. .
BIOMEDICAL OPTICS EXPRESS, 2011, 2 (06) :1539-1552