摘要
CT is a diagnostic tool with many clinical applications. The CT voxel intensity is related to the magnitude of X-ray attenuation, which is not unique to a given material. Substances with different chemical compositions can be represented by similar voxel intensities, making the classification of different tissue types challenging. Compared to the conventional single-energy CT, spectral CT is an emerging technology offering superior material differentiation, which is achieved using the energy dependence of X-ray attenuation in any material. A specific form of spectral CT is dual-energy imaging, in which an additional X-ray attenuation measurement is obtained at a second X-ray energy. Dual-energy CT has been implemented in clinical settings with great success. This paper reviews the theoretical basis and practical implementation of spectral/dualen-ergy CT.
引用
收藏
页码:86 / 96
页数:11
相关论文
共 57 条
[1]   Dual-energy CT quantitative imaging: a comparison study between twin-beam and dual-source CT scanners [J].
Almeida, Isabel P. ;
Schyns, Lotte E. J. R. ;
Ollers, Michel C. ;
van Elmpt, Wouter ;
Parodi, Katia ;
Landry, Guillaume ;
Verhaegen, Frank .
MEDICAL PHYSICS, 2017, 44 (01) :171-179
[2]   ENERGY-SELECTIVE RECONSTRUCTIONS IN X-RAY COMPUTERIZED TOMOGRAPHY [J].
ALVAREZ, RE ;
MACOVSKI, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (05) :733-744
[3]   Photon-counting spectral computed tomography using silicon strip detectors: a feasibility study [J].
Bornefalk, Hans ;
Danielsson, Mats .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (07) :1999-2022
[4]   BEAM HARDENING IN X-RAY RECONSTRUCTIVE TOMOGRAPHY [J].
BROOKS, RA ;
DICHIRO, G .
PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (03) :390-398
[5]  
Chandramohan M., 2018, DUAL ENERGY COMPOSIT
[6]   Determining the composition of urinary tract calculi using stone-targeted dual-energy CT: evaluation of a low-dose scanning protocol in a clinical environment [J].
Chaytor, Richard J. ;
Rajbabu, Krishnamoorthy ;
Jones, Paul A. ;
Mcknight, Liam .
BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1067)
[7]   Atherosclerotic Plaque Composition: Analysis with Multicolor CT and Targeted Gold Nanoparticles [J].
Cormode, David P. ;
Roessl, Ewald ;
Thran, Axel ;
Skajaa, Torjus ;
Gordon, Ronald E. ;
Schlomka, Jens-Peter ;
Fuster, Valentin ;
Fisher, Edward A. ;
Mulder, Willem J. M. ;
Proksa, Roland ;
Fayad, Zahi A. .
RADIOLOGY, 2010, 256 (03) :774-782
[8]   Initial Results of a Single-Source Dual-Energy Computed Tomography Technique Using a Split-Filter Assessment of Image Quality, Radiation Dose, and Accuracy of Dual-Energy Applications in an In Vitro and In Vivo Study [J].
Euler, Andre ;
Parakh, Anushri ;
Falkowski, Anna L. ;
Manneck, Sebastian ;
Dashti, David ;
Krauss, Bernhard ;
Szucs-Farkas, Zsolt ;
Schindera, Sebastian T. .
INVESTIGATIVE RADIOLOGY, 2016, 51 (08) :491-498
[9]   Image reconstruction and image quality evaluation for a dual source CT scanner [J].
Flohr, T. G. ;
Bruder, H. ;
Stierstorfer, K. ;
Petersilka, M. ;
Schmidt, B. ;
McCollough, C. H. .
MEDICAL PHYSICS, 2008, 35 (12) :5882-5897
[10]   First performance evaluation of a dual-source CT (DSCT) system [J].
Flohr, TG ;
McCollough, CH ;
Bruder, H ;
Petersilka, M ;
Gruber, K ;
Süss, C ;
Grasruck, M ;
Stierstorfer, K ;
Krauss, B ;
Raupach, R ;
Primak, AN ;
Küttner, A ;
Achenbach, S ;
Becker, C ;
Kopp, A ;
Ohnesorge, BM .
EUROPEAN RADIOLOGY, 2006, 16 (02) :256-268