Development of a new method to estimate thermal performance of multilayer radiant floor

被引:17
作者
Li, Qingqing [1 ,2 ]
Zhang, Ye [3 ]
Guo, Tieming [1 ]
Fan, Jianhua [2 ]
机构
[1] Qingdao Agr Univ, Sch Civil Engn & Architecture, Qingdao 266000, Peoples R China
[2] Tech Univ Denmark, Dept Civil Engn, Lyngby, Denmark
[3] Jiaxing Univ, Coll Architecture & Civil Engn, Jiaxing 314001, Zhejiang, Peoples R China
基金
中国国家自然科学基金; 浙江省自然科学基金;
关键词
Thermal performance; Radiant floor; Analytical solution; Temperature distribution; Thermal resistance;
D O I
10.1016/j.jobe.2020.101562
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
For a pipe-embedded concrete radiant floor, its thermal performance is essential to maintain the desired cooling/heating capacity and indoor thermal comfort. A good temperature distribution of the floor surface is very important in order to prevent occupant discomfort and avoid possible condensation in the case of floor cooling. In this study, a heat transfer model of a three-layer floor was developed by coupling 2-D and 1-D heat transfer problems. The analytical solution was developed and validated. The results of the calculations are in a good agreement with the experiments. The absolute error between the calculated and the measured floor surface temperatures was within 0.4.. The maximum relative error was within 2.2%. The proposed method can be utilized to calculate the thermal performance of a floor, either a one-layer floor, a two-layer floor or a three-layer floor. The thermal resistance of the floor with different structures can be calculated and used to estimate thermal performance of the floor. For the typical radiant floor, the range of thermal resistance is approximately 0.15-0.45 m(2)K/W with a pipe spacing from 0.1 to 0.5 m. With the overall floor temperature obtained, it is possible to identify the percentage of the floor area with a temperature higher than the limit and to estimate the overall and local occupant comfort. Based on the thermal resistance of the floor, an e-NTU method will be developed in the future study for design of a radiant floor.
引用
收藏
页数:11
相关论文
共 28 条
  • [11] Numerical simulation of radiant floor cooling system: The effects of thermal resistance of pipe and water velocity on the performance
    Jin, Xing
    Zhang, Xiaosong
    Luo, Yajun
    Cao, Rongquan
    [J]. BUILDING AND ENVIRONMENT, 2010, 45 (11) : 2545 - 2552
  • [12] A calculation method for the floor surface temperature in radiant floor system
    Jin, Xing
    Zhang, Xiaosong
    Luo, Yajun
    [J]. ENERGY AND BUILDINGS, 2010, 42 (10) : 1753 - 1758
  • [13] Kilkis B.I., 1995, SIMPLIFIED MODEL DES
  • [14] Interaction of an air system with concrete core conditioning
    Koschenz, M
    Dorer, V
    [J]. ENERGY AND BUILDINGS, 1999, 30 (02) : 139 - 145
  • [15] Development of a radiant heating and cooling model for building energy simulation software
    Laouadi, A
    [J]. BUILDING AND ENVIRONMENT, 2004, 39 (04) : 421 - 431
  • [16] Development of a simplified resistance and capacitance (RC)-network model for pipe-embedded concrete radiant floors
    Li, Anbang
    Sun, Yongjun
    Xu, Xinhua
    [J]. ENERGY AND BUILDINGS, 2017, 150 : 353 - 375
  • [17] Simplified thermal calculation method for floor structure in radiant floor cooling system
    Li, Qing-qing
    Chen, Chao
    Zhang, Ye
    Lin, Jie
    Ling, Hao-shu
    [J]. ENERGY AND BUILDINGS, 2014, 74 : 182 - 190
  • [18] Analytical solution for heat transfer in a multilayer floor of a radiant floor system
    Li, Qing-qing
    Chen, Chao
    Zhang, Ye
    Lin, Jie
    Ling, Hao-shu
    Ma, Yun
    [J]. BUILDING SIMULATION, 2014, 7 (03) : 207 - 216
  • [19] Establishment and validation of modified star-type RC-network model for concrete core cooling slab
    Liu, Kuixing
    Tian, Zhe
    Zhang, Cheng
    Ding, Yan
    Wang, Weiliang
    [J]. ENERGY AND BUILDINGS, 2011, 43 (09) : 2378 - 2384
  • [20] [刘艳峰 Liu Yanfeng], 2003, [哈尔滨工业大学学报, Journal of Harbin Institute of Technology], V35, P1190