Wireless Passive Time-of-Flight Respiratory MEMS Flow Rate Sensor

被引:0
|
作者
Moradian, Sina [1 ]
Akhkandi, Parvin [1 ]
Fatemi, Hedy [1 ]
Abdolvand, Reza [1 ]
机构
[1] Univ Cent Florida, Dept Elect & Comp Engn, Orlando, FL 32816 USA
基金
美国国家科学基金会;
关键词
MEMS; Passive Sensing; Time-of-flight; Respiratory sensor; Wearable Sensor;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Here we present the first instance of passive wireless MEMS flow rate sensor designed to measure respiratory flow rate and profile using the time-of-flight sensing modality without the need for battery or on-sensor circuits. With a footprint of only 7.2cm(2), the sensor can measure human respiratory rate and flow when placed close to the nasal airway using an excitation antenna that transmits an average power of similar to 5mW at a similar to 75cm distance. To facilitate the time-of-flight sensor, two low loss, high quality factor TPoS MEMS resonators are placed similar to 1cm apart and are connected to a small (3.8cm(2)) planar ground antenna. We were able to measure flow rate and respiration profile of human subject from a distance of 20cm from the base transceiver. In addition to flow rate, we were capable of accurately tracking the respiration profile of the patient and successfully detecting short cessation of breathing events commonly used in diagnosing sleep apnea.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Time-of-flight sensor for respiratory motion gating
    Schaller, Christian
    Penne, Jochen
    Hornegger, Joachim
    MEDICAL PHYSICS, 2008, 35 (07) : 3090 - 3093
  • [2] Passive wireless respiratory sensor
    Feng, Bin
    Zhao, Kai
    Su, Qiucheng
    Yu, Zhentao
    Jin, Hao
    ELECTRONICS LETTERS, 2021, 57 (19) : 730 - 731
  • [3] Numerical and analytic study on the time-of-flight thermal flow sensor
    Byon, Chan
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2015, 89 : 454 - 459
  • [4] Optical flow sensor based on the thermal time-of-flight measurement
    Hribar, Jernej
    Donlagic, Denis
    OPTICS EXPRESS, 2021, 29 (06) : 8846 - 8860
  • [5] Radio frequency (RF) time-of-flight ranging for wireless sensor networks
    Thorbjornsen, B.
    White, N. M.
    Brown, A. D.
    Reeve, J. S.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2010, 21 (03)
  • [6] Holographic optical element for laser time-of-flight flow sensor
    Dam-Hansen, C
    Kitchen, SR
    OPTICS AND LASERS IN ENGINEERING, 2006, 44 (09) : 954 - 964
  • [7] Noncontact Measurement of Respiratory Rate by an Optical Time of Flight Sensor
    Bachir, Wesam
    Khamaysa, Ahmad F. K.
    Iwasinska-Kowalska, Olga
    IEEE ACCESS, 2024, 12 : 156442 - 156457
  • [8] A Time-of-Flight and Radar Dataset of a neonatal Thorax Simulator with synchronized Reference Sensor Signals for respiratory Rate Detection
    Johanna Gleichauf
    Sven Herrmann
    Christine Niebler
    Alexander Koelpin
    Scientific Data, 11
  • [9] A Time-of-Flight and Radar Dataset of a neonatal Thorax Simulator with synchronized Reference Sensor Signals for respiratory Rate Detection
    Gleichauf, Johanna
    Herrmann, Sven
    Niebler, Christine
    Koelpin, Alexander
    SCIENTIFIC DATA, 2024, 11 (01)
  • [10] Toward Respiratory Assessment Using Depth Measurements from a Time-of-Flight Sensor
    Sharp, Charles
    Soleimani, Vahid
    Hannuna, Sion
    Camplani, Massimo
    Damen, Dima
    Viner, Jason
    Mirmehdi, Majid
    Dodd, James W.
    FRONTIERS IN PHYSIOLOGY, 2017, 8