A Simple Method to Predict Temperatures in Steel Joints with Partial Intumescent Coating Fire Protection

被引:19
作者
Dai, Xianghe [1 ]
Wang, Yong [1 ]
Bailey, Colin [1 ]
机构
[1] Univ Manchester, Sch Mech Aerosp & Civil Engn, Manchester, Lancs, England
基金
英国工程与自然科学研究理事会;
关键词
steel joints; partial fire protection; intumescent coating; temperature prediction; exposure factor; fire resistance;
D O I
10.1007/s10694-009-0095-7
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Based on temperatures measured in steel joints with different extents of fire protection, this paper proposes a simple method to calculate temperatures in steel joints with partial intumescent coating fire protection. The method combines the simple temperature calculation methods in EN 1993-1-2 (Committee of European Normalisation CEN, Eurocode 3: design of steel structures-part 1-2: general rules-structural fire design, 2005) for unprotected and protected steel structures through the introduction of an exposure factor, which is the ratio of the unprotected surface area of the joint region to the total surface area of the joint area. Using the measured temperatures for fully protected steel joints, this paper first extracts the effective thermal conductivity of the intumescent coating used in the fire tests. Afterwards, this paper presents validation results based on fire test results on joints with partial fire protection. Finally, this paper presents methods to calculate the exposure factor for different types of partially fire protected steel joints.
引用
收藏
页码:19 / 35
页数:17
相关论文
共 12 条
  • [1] BAILEY CG, 2007, STEEL COMPOSITE STRU
  • [2] *BRIT STAND I, 1338142002E DD ENV B
  • [3] *CEN, 1995, 199312 CEN ENV BRIT
  • [4] *CEN, 2005, 1993122005E CEN BS E
  • [5] *CEN, 2002, 1991122002E CEN BS E
  • [6] Effects of partial fire protection on temperature developments in steel joints protected by intumescent coating
    Dai, X. H.
    Wang, Y. C.
    Bailey, C. G.
    [J]. FIRE SAFETY JOURNAL, 2009, 44 (03) : 376 - 386
  • [7] DAI XH, 2007, STEEL COMPOSITE STRU
  • [8] FEMA, 2002, WORLD TRAD CTR BUILD
  • [9] Calculation of temperature in fire-exposed bare steel structures: Comparison between ENY 1993-1-2 and EN 1993-1-2
    Franssen, JM
    [J]. FIRE SAFETY JOURNAL, 2006, 41 (02) : 139 - 143
  • [10] *ISE, 2002, SAF TALL BUILD BUILD