摘要
This study was designed to evaluate the safety and performance of Metafor (TM) SES in real-world patients with coronary artery disease. This was retrospective, single-centre, post-marketing, observational study. The primary endpoint was the occurrence of major adverse cardiac event (MACE). A total of 141 patients (187 lesions) were treated with the study device. The average stent length and diameter was 24.75 +/- 9.50 mm and 2.93 +/- 0.38 mm, respectively. The cumulative incidence of MACE was 1.42%. No incidence of stent thrombosis was observed at 12-months follow-up. This retrospective study demonstrated favourable safety and performance of Metafor (TM) SES. (C) 2020 Cardiological Society of India. Published by Elsevier B.V.
引用
收藏
页码:114 / 116
页数:3
相关论文
共 11 条
[1]   Impact of stent deployment procedural factors on long-term effectiveness and safety of sirolimus-eluting stents (final results of the multicenter prospective STLLR trial) [J].
Costa, Marco A. ;
Angiolillo, Dominick J. ;
Tannenbaum, Mark ;
Driesman, Mitchell ;
Chu, Alan ;
Patterson, John ;
Kuehl, William ;
Battaglia, Joseph ;
Dabbons, Samir ;
Shamoon, Fayez ;
Flieshman, Bruce ;
Niederman, Alan ;
Bass, Theodore A. .
AMERICAN JOURNAL OF CARDIOLOGY, 2008, 101 (12) :1704-1711
[2]   Clinical end points in coronary stent trials - A case for standardized definitions [J].
Cutlip, Donald E. ;
Windecker, Stephan ;
Mehran, Roxana ;
Boam, Ashley ;
Cohen, David J. ;
van Es, Gerrit-Anne ;
Steg, P. Gabriel ;
Morel, Marie-angele ;
Mauri, Laura ;
Vranckx, Pascal ;
McFadden, Eugene ;
Lansky, Alexandra ;
Hamon, Martial ;
Krucoff, Mitchell W. ;
Serruys, Patrick W. .
CIRCULATION, 2007, 115 (17) :2344-2351
[3]  
Kasturi S, 2017, WJCD, V7, P233
[4]   Clinical outcomes in 995 unselected real-world patients treated with an ultrathin biodegradable polymer-coated sirolimus-eluting stent: 12-month results from the FLEX Registry [J].
Lemos, Pedro A. ;
Chandwani, Prakash ;
Saxena, Sudheer ;
Ramachandran, Padma Kumar ;
Abhyankar, Atul ;
Campos, Carlos M. ;
Marchini, Julio Flavio ;
Galon, Micheli Zanotti ;
Verma, Puneet ;
Sandhu, Manjinder Singh ;
Parikh, Nikhil ;
Bhupali, Ashok ;
Jain, Sharad ;
Prajapati, Jayesh .
BMJ OPEN, 2016, 6 (02)
[5]   Contemporary Incidence and Predictors of Stent Thrombosis and Other Major Adverse Cardiac Events in the Year After XIENCE V Implantation [J].
Naidu, Srihari S. ;
Krucoff, Mitchell W. ;
Rutledge, David R. ;
Mao, Vivian W. ;
Zhao, Weiying ;
Zheng, Qing ;
Wilburn, Olivia ;
Sudhir, Krishnankutty ;
Simonton, Charles ;
Hermiller, James B. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (06) :626-635
[6]   Clinical Outcomes With Bioabsorbable Polymer-Versus Durable Polymer-Based Drug-Eluting and Bare-Metal Stents Evidence From a Comprehensive Network Meta-Analysis [J].
Palmerini, Tullio ;
Biondi-Zoccai, Giuseppe ;
Della Riva, Diego ;
Mariani, Andrea ;
Sabate, Manel ;
Smits, Pieter C. ;
Kaiser, Christoph ;
D'Ascenzo, Fabrizio ;
Frati, Giacomo ;
Mancone, Massimo ;
Genereux, Philippe ;
Stone, Gregg W. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (04) :299-307
[7]   Effect of Biolimus-Eluting Stents With Biodegradable Polymer vs Bare-Metal Stents on Cardiovascular Events Among Patients With Acute Myocardial Infarction The COMFORTABLE AMI Randomized Trial [J].
Raeber, Lorenz ;
Kelbaek, Henning ;
Ostoijc, Miodrag ;
Baumbach, Andreas ;
Heg, Dik ;
Tueller, David ;
von Birgelen, Clemens ;
Roffi, Marco ;
Moschovitis, Aris ;
Khattab, Ahmed A. ;
Wenaweser, Peter ;
Bonvini, Robert ;
Pedrazzini, Giovanni ;
Kornowski, Ran ;
Weber, Klaus ;
Trelle, Sven ;
Luescher, Thomas F. ;
Taniwaki, Masanori ;
Matter, Christian M. ;
Meier, Bernhard ;
Jueni, Peter ;
Windecker, Stephan .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2012, 308 (08) :777-787
[8]  
Rao Prakasa VS, 2017, WORLD J CARDIOV DIS, V7, P163, DOI DOI 10.4236/WJCD.2017.75015
[9]   Experience with Biodegradable Polymer Coated Sirolimus-Eluting Coronary Stent System in "Real-Life" Percutaneous Coronary Intervention: 24-Month Data from the Manipal-S Registry [J].
Shetty, Ranjan ;
Vivek, G. ;
Thakkar, Ashok ;
Mishra, Supriya Sunder ;
Joseph, Vivek ;
Devraj, Mithun Gopal ;
Tumkur, Anil ;
Pai, Unlash .
JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2013, 7 (09) :1959-1963
[10]   Biodegradable polymer drug-eluting stents reduce the risk of stent thrombosis at 4 years in patients undergoing percutaneous coronary intervention: a pooled analysis of individual patient data from the ISAR-TEST 3, ISAR-TEST 4, and LEADERS randomized trials [J].
Stefanini, Giulio G. ;
Byrne, Robert A. ;
Serruys, Patrick W. ;
de Waha, Antoinette ;
Meier, Bernhard ;
Massberg, Steffen ;
Jueni, Peter ;
Schoemig, Albert ;
Windecker, Stephan ;
Kastrati, Adnan .
EUROPEAN HEART JOURNAL, 2012, 33 (10) :1214-1222