Effect of different biocompatible implant materials on the mechanical stability of dental implants under excessive oblique load

被引:39
|
作者
Bataineh, Khaled [1 ]
Al Janaideh, Mohammad [1 ]
机构
[1] Jordan Univ Sci & Technol, Dept Mech Engn, POB 3030, Irbid 2210, Jordan
关键词
biocompatible; biomaterials; CFR-PEEK; deformation; dental implant; fatigue; finite element simulation; stress distribution;
D O I
10.1111/cid.12858
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: Metallic implants such as titanium are much harder than the neighboring bone. This high difference may generate larger stress at the bone-implant interface during load transfer which leads to implant failure. The use of biocompatible polymer such as CRF-polyether ether ketone (PEEK) with strength comparable with the bone might lead to lower and better stress distribution to the supporting periimplant bone. Purpose: The aim of this study is to investigate the effect of using carbon reinforced PEEK composite material for fixture/abutment on stress distribution in periimplant bone. Materials and Methods: Three-dimensional (3D) model of dental implant placed in the first mandibular molar is constructed from computed tomography scan. Five distinct models using a combination of titanium, CRF-PEEK, lithium disilicate for implant/abutment materials are studied. 3D finite element analysis (FEA) is used to evaluate the stress distribution at implant-bone interface under excessive oblique load. The physical interaction between several contacting bodies is numerically investigated. The effect of friction coefficients between the indenter and occlusal surface and between the implant and peri-implant bone is determined. Results: FEA results show that there is no significant difference in the distribution pattern of stress at implant-bone interface among the different material models studied. The highest maximum and lowest minimum principal stresses were always located in the cortical bone and never in the cancellous bone which is consistent with the existing literature. Off-axis loading can result in unfavorable forces on the implant, jeopardizing the long-term success because of excessive lateral loads. Current FEA results agree with previously published work. Conclusion: Substitution of titanium implant by PEEK implant does not provide any advantages in regards to better stress distribution to the peri-implant bone. The strain thresholds of Frost's mechanostat theory that are suitable for long bone could not be applied for alveolar bone.
引用
收藏
页码:1206 / 1217
页数:12
相关论文
共 11 条
  • [1] Effect of Different Crown Removing Procedures on the Implant Stability Quotient and Removal Torque Values of Dental Implants
    Akin, Hakan
    Unal, Yasemen
    Yilmazer, Kaan
    CLINICAL AND EXPERIMENTAL HEALTH SCIENCES, 2021, 11 (02): : 314 - +
  • [2] EFFECT OF DIFFERENT ABUTMENT MATERIALS ON STRESS DISTRIBUTION IN PERIPHERAL BONE AND DENTAL IMPLANT SYSTEM
    Terzi, Merve
    Guvercin, Yilmaz
    Ates, Sabit Melih
    Sekban, Dursun Murat
    Yaylaci, Murat
    SIGMA JOURNAL OF ENGINEERING AND NATURAL SCIENCES-SIGMA MUHENDISLIK VE FEN BILIMLERI DERGISI, 2020, 38 (03): : 1495 - 1507
  • [4] Comparison of Stress Distribution in Surrounding Bone during Insertion of Dental Implants on Four Implant Threads under the Effect of an Impact: A Finite Element Study
    Djebbar, N.
    Bachiri, A.
    Boutabout, B.
    JOURNAL OF BIOMIMETICS BIOMATERIALS AND BIOMEDICAL ENGINEERING, 2021, 54 : 89 - 101
  • [5] A Systematic Study of Restorative Crown-Materials Combinations for Dental Implants: Characterization of Mechanical Properties under Dynamic Loads
    Marimon, Xavier
    Cerrolaza, Miguel
    Ferrer, Miquel
    Canto-Naves, Oriol
    Cabratosa-Termes, Josep
    Perez, Roman
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2022, 23 (15)
  • [6] Effects of different numbers of mini-dental implants on alveolar ridge strain distribution under mandibular implant-retained overdentures
    Warin, Pongsakorn
    Rungsiyakull, Pimduen
    Rungsiyakull, Chaiy
    Khongkhunthian, Pathawee
    JOURNAL OF PROSTHODONTIC RESEARCH, 2018, 62 (01) : 35 - 43
  • [7] Load Fatigue Performance Evaluation on Two Internal Tapered Abutment-Implant Connection Implants Under Different Screw Tightening Torques
    Jeng, Ming-Dih
    Liu, Po-Yi
    Kuo, Jia-Hum
    Lin, Chun-Li
    JOURNAL OF ORAL IMPLANTOLOGY, 2017, 43 (02) : 107 - 114
  • [8] The effect of implant splinting on the load distribution in bone bed around implant-supported fixed prosthesis with different framework materials: A finite element study
    Hasan, I.
    Bourauel, C.
    Keilig, L.
    Stark, H.
    Lueckerath, W.
    ANNALS OF ANATOMY-ANATOMISCHER ANZEIGER, 2015, 199 : 43 - 51
  • [9] Effect of the Location of Dental Mini-Implants on Strain Distribution under Mandibular Kennedy Class I Implant-Retained Removable Partial Dentures
    Rungsiyakull, Pimduen
    Kujarearntaworn, Kallaya
    Khongkhunthian, Pathawee
    Swain, Michael
    Rungsiyakull, Chaiy
    INTERNATIONAL JOURNAL OF DENTISTRY, 2021, 2021
  • [10] Mechanical stability of all-ceramic abutments retained with three different screw materials in two-piece zirconia implants-an in vitro study
    Stimmelmayr, Michael
    Lang, Anna
    Beuer, Florian
    Mansour, Sonia
    Erdelt, Kurt
    Krennmair, Gerald
    Gueth, Jan-Frederik
    CLINICAL ORAL INVESTIGATIONS, 2020, 24 (05) : 1801 - 1806