Endoluminal stent graft repair for acute and chronic type B aortic dissection and atherosclerotic aneurysm of the thoracic aorta: an interdisciplinary task

被引:56
|
作者
Herold, U [1 ]
Piotrowski, J
Baumgart, D
Eggebrecht, H
Erbel, R
Jakob, H
机构
[1] Univ Essen Gesamthsch, Dept Cardiovasc & Thorac Surg, D-45147 Essen, Germany
[2] Univ Essen Gesamthsch, Dept Cardiol, D-45147 Essen, Germany
关键词
endoluminal stent graft; stent graft repair; thoracic aortic aneurysm; thoracic aortic aneurysm repair; aortic dissection;
D O I
10.1016/S1010-7940(02)00563-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Endoluminal thoracic aortic stenting is a new therapeutic tool in reducing the operative trauma of the patient. However, the inherent risks of aortic stent grafting are perivascular leakage, stent dislocation, blunt rupture of the aorta, side branch occlusion and neurological sequelae. To reduce these risks, in our institution all stent implantations were performed in close collaboration with our fellow cardiologists under biplane X-ray control supported by simultaneous intravascular and transoesophageal ultrasound imaging. Methods: Between August 1999 and August 2001, endovascular stent graft repair was performed in 34 patients (27 male, seven female) with a mean age of 68.6 +/- 7 years (range 58-84). Indication for treatment was an acute Type B aortic dissection in six patients (18%), a symptomatic chronic Type B dissection in 12 patients (35%), a true aneurysm of the descending aorta in seven patients (21%) and an atherosclerotic contained rupture of the descending aorta in nine (26%) patients. Out of six acute type B dissections three patients (8.8%) and one patient (2.9%) out of the chronic dissection group were in severe haemorrhagic shock, ventilated and required high-dose adrenergic support. The others (30 patients, 88.3%) remained symptomatic despite maximum medical treatment. In a special case a combined surgical and endoluminal stent graft repair was performed. Individually manufactured Talent, Medtronic AVE (33), and Gore (1) stents were used. Follow-up examination was performed I week after implantation and repeated every 3 months (mean follow-up 8 months, range 1-24). Results: In all patients the aneurysm or the entry of the dissection could be excluded. The observed hospital mortality was 2.9% (one patient). No perivascular leakage, no stent dislocation, no neurological deficit or perfusion impairment was observed. All patients except four were extubated immediately after the procedure and discharged from hospital on postoperative day 2-3. The late procedure-related mortality was 5.8% (two patients) resulting in an overall mortality of 8.8% (three patients). Conclusion: Stent graft repair is a safe and feasible treatment option for selected patients, especially in emergency situations, if the aortic lesions can be clearly identified and localized. The use of biplane X-ray control combined with simultaneous intravascular and transoesophageal ultrasound imaging in an interdisciplinary approach enables a more precise targeting of the stent landing zone, resulting in low morbidity and mortality rates. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:891 / 897
页数:7
相关论文
共 50 条
  • [1] Computational investigation of interaction between stent graft and aorta in retrograde type A dissection after thoracic endovascular aortic repair for type B aortic dissection
    Ma, Tao
    Dong, Zhi Hui
    Wang, Shengzhang
    Meng, Zhuang Yuan
    Chen, Yin Yin
    Fu, Wei Guo
    JOURNAL OF VASCULAR SURGERY, 2018, 68 (06) : 14S - +
  • [2] Thoracic Endovascular Aortic Repair in Acute and Chronic Type B Aortic Dissection
    Trimarchi, Santi
    Eagle, Kim A.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (02) : 192 - 194
  • [3] Stent-graft repair in acute and chronic diseases of the thoracic aorta
    Kische, Stephan
    Akin, Ibrahim
    Ince, Hueseyin
    Rehders, Tim C.
    Schneider, Henrik
    Ortak, Jasmin
    Nienaber, Christoph A.
    REVISTA ESPANOLA DE CARDIOLOGIA, 2008, 61 (10): : 1070 - 1086
  • [4] Endoluminal stent graft implantation for aneurysm of descending thoracic aorta - a case report
    Bohm, B
    Wagner, W
    Bartel, M
    Soldner, A
    Rott, A
    ZENTRALBLATT FUR CHIRURGIE, 1998, 123 (01): : 72 - 75
  • [5] A Novel Vascular-Friendly Thoracic Stent Graft for Endovascular Repair of Acute Complicated Type B Aortic Dissection
    Jin, Jie
    Jiang, Qingjun
    Bai, Jun
    Qu, Lefeng
    ANNALS OF THORACIC AND CARDIOVASCULAR SURGERY, 2021, 27 (03) : 200 - 206
  • [6] Late thoracic endovascular stent graft repair after complicated acute type B dissection
    Ozcan, Sedat
    Kunt, Aysegul
    Odabasi, Dolunay
    TURK GOGUS KALP DAMAR CERRAHISI DERGISI-TURKISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2016, 24 (01): : 133 - 136
  • [7] Hybrid Thoracic Stent Graft Repair of a Complex Type B Aortic Dissection in a Patient Who Presented Three Weeks After Repair of a Type A Aortic Dissection
    Gaur, Puja
    Kasirajan, Karthikeshwar
    Miller, Daniel L.
    Vassiliades, Thomas A., Jr.
    INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2008, 3 (03) : 158 - 160
  • [8] Thoracic endovascular aortic repair for acute type B aortic dissection complicated by total occlusion of the abdominal aorta
    Shikata, Daichi
    Omura, Atsushi
    Matsuo, Jiro
    Matsuda, Hitoshi
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2020, 30 (06) : 940 - 942
  • [9] Comparison of a percutaneous separate stent endograft and a conventional thoracic stent-graft for endovascular repair of type B aortic dissection
    Park, S
    Min, PK
    Joung, B
    Ko, YG
    Choi, D
    Jang, Y
    Lee, DY
    Chang, BC
    Shim, WH
    JOURNAL OF ENDOVASCULAR THERAPY, 2004, 11 (04) : 378 - 384
  • [10] The Role of Thoracic Endovascular Repair in Chronic Type B Aortic Dissection
    Burke, Christopher R.
    Bavaria, Joseph E.
    SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2020, 32 (01) : 21 - 24