Based on Inverse Transient Analysis (ITA) method, a real-time leak detection method is proposed to capture leak location and the associated leak rate in oil pipe conveyance systems. In the proposed approach, location and flow rate of leak (if any), the fluid properties, as well as physical parameters of the system, are calculated in consecutive periods through minimizing the discrepancy between the calculated and measured flow parameters of the system. The method of characteristics is employed to numerically calculate the transient responses of the system and the genetic algorithm is utilized as the optimization engine. The proposed approach was applied to several real pipeline systems in which the required transient flow data are either directly collected from the field or fabricated with a third-party numerical software. Extensive numerical explorations were conducted to investigate the performance of the proposed method in real-time leak detection and to determine the extent to which field data errors, stemming from Supervisory Control and Data Acquisition (SCADA) systems and mea-surement equipment, affect the leak flow rate and location detectability of the proposed approach. The results show that the proposed approach provides promising results under a variety of transient and steady-state flow conditions even in the case with small leak flow rate of around 2% of the line rate. The results also reveal that the noises in the measurement data and the errors originated from SCADA systems do not significantly compromise the leak detectability of the proposed approach, confirming that the proposed approach can be utilized in practice.
引用
收藏
页数:13
相关论文
共 49 条
[1]   Recent Advances in Pipeline Monitoring and Oil Leakage Detection Technologies: Principles and Approaches [J].
Adegboye, Mutiu Adesina ;
Fung, Wai-Keung ;
Karnik, Aditya .
SENSORS, 2019, 19 (11)
[2]   Leak detection in long pipelines using the least squares method [J].
Al-Khomairi, Abdulrahman .
JOURNAL OF HYDRAULIC RESEARCH, 2008, 46 (03) :392-401
[3]  
Balda K.V., 2012, THESIS U OKLAHOMAS
[4]   Water hammer with column separation: A historical review [J].
Bergant, A ;
Simpson, AR ;
Tijsseling, AS .
JOURNAL OF FLUIDS AND STRUCTURES, 2006, 22 (02) :135-171
[5]   Leak Detection in a Branched System by Inverse Transient Analysis with the Admittance Matrix Method [J].
Capponi, Caterina ;
Ferrante, Marco ;
Zecchin, Aaron C. ;
Gong, Jinzhe .
WATER RESOURCES MANAGEMENT, 2017, 31 (13) :4075-4089
[6]   Effect of rubber washers on leak location for assembled pressurized liquid pipeline based on negative pressure wave method [J].
Chen, Qiang ;
Shen, Guodong ;
Jiang, JunCheng ;
Diao, Xu ;
Wang, Zhirong ;
Ni, Lei ;
Dou, Zhan .
PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2018, 119 :181-190
[7]  
Chun-xia Hou, 2013, Applied Mechanics and Materials, V313-314, P1225, DOI 10.4028/www.scientific.net/AMM.313-314.1225
[8]   A selective literature review of transient-based leak detection methods [J].
Colombo, Andrew F. ;
Lee, Pedro ;
Karney, Bryan W. .
JOURNAL OF HYDRO-ENVIRONMENT RESEARCH, 2009, 2 (04) :212-227
[9]   A review on different pipeline fault detection methods [J].
Datta, Shantanu ;
Sarkar, Shibayan .
JOURNAL OF LOSS PREVENTION IN THE PROCESS INDUSTRIES, 2016, 41 :97-106
[10]   Wavelets for the analysis of transient pressure signals for leak detection [J].
Ferrante, Marco ;
Brunone, Bruno ;
Meniconi, Silvia .
JOURNAL OF HYDRAULIC ENGINEERING, 2007, 133 (11) :1274-1282