Optimal planning of distribution grids considering active power curtailment and reactive power control

被引:0
作者
Karagiannopoulos, Stavros [1 ]
Aristidou, Petros [1 ]
Ulbig, Andreas [1 ]
Koch, Stephan [1 ]
Hug, Gabriela [1 ]
机构
[1] Swiss Fed Inst Technol, EEH Power Syst Lab, Phys Str 3, CH-8092 Zurich, Switzerland
来源
2016 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING (PESGM) | 2016年
关键词
distribution grid planning; distributed energy resources; curtailment; reactive control; optimal power flow; SYSTEMS;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this paper, a new planning methodology is proposed for existing distribution grids, considering both passive and active network measures. The method is designed to be tractable for large grids of any type, e.g., meshed or radial. It can be used as a decision-making tool by distribution system operators which need to decide whether to invest in new hardware, such as new lines and transformers, or to initiate control measures influencing the operational costs. In this paper, active power curtailment and reactive power control are taken into account as measures to prevent unacceptable voltage rises as well as element overloads, as these allow postponing network investments. A low-voltage, meshed grid with 27 nodes is used to demonstrate the proposed scheme. In this particular case, the results show that by using control measures, an active distribution system operator can defer investments and operate the existing infrastructure more efficiently. The methodology is able to account for variations in operational and investment costs coming from regulatory influences to provide an insight to the most costefficient decision.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Reactive Power Planning for Regional Power Grids Based on Active and Reactive Power Adjustments of DGs
    Shen, Yangwu
    Shen, Feifan
    Chen, Yaling
    Liang, Liqing
    Zhang, Bin
    Ke, Deping
    ENERGIES, 2018, 11 (06):
  • [2] Multi-Year High-Voltage Power System Planning Considering Active Power Curtailment
    Schaefer, Florian
    Braun, Martin
    ENERGIES, 2020, 13 (18)
  • [3] Retrospective Optimal Power Flow for Low Discriminating Active Power Curtailment
    Meier, Fricdcrikc
    Toebermann, Christian
    Braun, Martin
    2019 IEEE MILAN POWERTECH, 2019,
  • [4] Optimal power flow based coordinated reactive and active power control to mitigate voltage violations in smart inverter enriched distribution network
    Wagle, Raju
    Sharma, Pawan
    Sharma, Charu
    Amin, Mohammad
    INTERNATIONAL JOURNAL OF GREEN ENERGY, 2024, 21 (02) : 359 - 375
  • [5] Forecast of Renewable Curtailment in Distribution Grids Considering Uncertainties
    Memmel, Elena
    Schlueters, Sunke
    Voelker, Rasmus
    Schuldt, Frank
    Von Maydell, Karsten
    Agert, Carsten
    IEEE ACCESS, 2021, 9 : 60828 - 60840
  • [6] Optimal Coordinated EV Charging with Reactive Power Support in Constrained Distribution Grids
    Paudyal, Sumit
    Ceylan, Oguzhan
    Bhattarai, Bishnu P.
    Myers, Kurt S.
    2017 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, 2017,
  • [7] Decentralized Reactive Power Control in Distribution Grids With Unknown Reactance Matrix
    Ye, Lintao
    Kosaraju, Krishna Chaitanya
    Gupta, Vijay
    Trevizan, Rodrigo D.
    Byrne, Raymond H.
    Chalamala, Babu R.
    IEEE OPEN ACCESS JOURNAL OF POWER AND ENERGY, 2024, 11 : 154 - 164
  • [8] Voltage Control of Distribution Grids with Multi-Microgrids Using Reactive Power Management
    Wlodarczyk, Piotr
    Sumper, Andreas
    Cruz, Miguel
    ADVANCES IN ELECTRICAL AND COMPUTER ENGINEERING, 2015, 15 (01) : 83 - 88
  • [9] Probabilistic Flexibility Evaluation for Power System Planning Considering Its Association With Renewable Power Curtailment
    Lu, Zongxiang
    Li, Haibo
    Qiao, Ying
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2018, 33 (03) : 3285 - 3295
  • [10] Stochastic optimal reactive power planning and active power dispatch with large penetration of wind generation
    Gupta, Neeraj
    JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2018, 10 (02)