Development and clinical application of meniscal unicompartmental arthroplasty

被引:18
作者
O'Connor, J. J.
Goodfellow, J. W.
Dodd, C. A. F.
Murray, D. W.
机构
[1] Univ Oxford, Dept Engn Sci, Oxford OX1 3PJ, England
[2] Univ Oxford, Oxford Orthopaed Engn Ctr, Oxford OX1 3PJ, England
[3] Nuffield Orthopaed Ctr, Oxford OX3 7LD, England
[4] Univ Oxford, Botnar Res Ctr, Oxford, England
关键词
medial compartment knee replacement; anteromedial osteoarthritis; fully conforming design; unconstrained design; retrieval studies; tibiofemoral movement;
D O I
10.1243/09544119JEIM251
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
About one-third of osteoarthritic patients requiring knee replacement have focal lesions limited mainly to the medial compartment and can achieve excellent postoperative function after medial unicompartmental replacement. However, late failures of many unicompartmental prostheses require revision at a rate about twice that of total knee replacement. The use of a fully conforming mobile-bearing meniscal unicompartmental prosthesis in the hands of experienced surgeons can reduce revision rates to levels equivalent to the best results achieved with total knee replacement. The paper argues the case for such a prosthesis and demonstrates that the usual modes of failure of unicompartmental arthroplasty, most of them biornechanical, can thereby be avoided.
引用
收藏
页码:47 / 59
页数:13
相关论文
共 90 条
[1]  
[Anonymous], 1995, The Knee, DOI 10.1016/0968-0160(95)00017-J
[2]   POLYETHYLENE WEAR IN MENISCAL KNEE REPLACEMENT - A ONE TO 9-YEAR RETRIEVAL ANALYSIS OF THE OXFORD KNEE [J].
ARGENSON, JN ;
OCONNOR, JJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (02) :228-232
[3]   Polyethylene wear in a non-congruous unicompartmental knee replacement: a retrieval analysis [J].
Ashraf, T ;
Newman, JH ;
Desai, VV ;
Beard, D ;
Nevelos, JE .
KNEE, 2004, 11 (03) :177-181
[4]   Lateral unicompartmental knee replacement - Survivorship and clinical experience over 21 [J].
Ashraf, T ;
Newman, JH ;
Evans, RL ;
Ackroyd, CE .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B (08) :1126-1130
[5]  
BAE DK, 1983, CLIN ORTHOP RELAT R, P233
[6]   The influence of stress conditions on the wear of UHMWPE for total joint replacements [J].
Barbour, PSM ;
Barton, DC ;
Fisher, J .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1997, 8 (10) :603-611
[7]   Results of unicompartmental knee arthroplasty at a minimum of ten years of follow-up [J].
Berger, RA ;
Meneghini, RM ;
Jacobs, JJ ;
Sheinkop, MB ;
Della Valle, CJ ;
Rosenberg, AG ;
Galante, JO .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (05) :999-1006
[8]   POLYETHYLENE WEAR IN UNICONDYLAR KNEE PROSTHESES - 106 RETRIEVED MARMOR, PCA, AND ST-GEORG TIBIAL COMPONENTS COMPARED [J].
BLUNN, GW ;
JOSHI, AB ;
LILLEY, PA ;
ENGELBRECHT, E ;
RYD, L ;
LIDGREN, L ;
HARDINGE, K ;
NIEDER, E ;
WALKER, PS .
ACTA ORTHOPAEDICA SCANDINAVICA, 1992, 63 (03) :247-255
[9]   Wear in retrieved condylar knee arthroplasties - A comparison of wear in different designs of 280 retrieved condylar knee prostheses [J].
Blunn, GW ;
Joshi, AB ;
Minns, RJ ;
Lidgren, L ;
Lilley, P ;
Ryd, L ;
Engelbrecht, E ;
Walker, PS .
JOURNAL OF ARTHROPLASTY, 1997, 12 (03) :281-290
[10]   A RADIOGRAPHIC STUDY OF BEARING MOVEMENT IN UNICOMPARTMENTAL OXFORD KNEE REPLACEMENTS [J].
BRADLEY, J ;
GOODFELLOW, JW ;
OCONNOR, JJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1987, 69 (04) :598-601