Disposable Bismuth Oxide Screen Printed Electrodes for the High Throughput Screening of Heavy Metals

被引:94
作者
Kadara, Rashid O. [1 ]
Jenkinson, Norman [1 ]
Banks, Craig E. [1 ]
机构
[1] Manchester Metropolitan Univ, Fac Sci & Engn, Sch Biol Chem & Hlth Sci, Div Chem & Mat, Manchester M1 5GD, Lancs, England
关键词
Bismuth electrodes; Screen printing; High-throughput screening; Electroanalysis; FILM ELECTRODE; CADMIUM(II); LEAD;
D O I
10.1002/elan.200900266
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We present a simplified approach for the trace screening of toxic heavy metals utilizing bismuth oxide screen printed electrodes. The use of bismuth oxide instead of toxic mercury films facilitates the reliable sensing of lead(II), cadmium(II) and zinc(H). A linear range over 5 to 150 mu g L-1 with detection limits of 2.5 and 5 mu g L-1 are readily observed for cadmium and lead in 0.1 M HCl, respectively. Conducting a simultaneous multi-elemental voltammetric detection of zinc, cadmium and lead in a higher pH medium (0.1 M sodium acetate solution) exhibited a linear range between 10 and 150 mu g L-1 with detection limits of 5, 10 and 30 mu g L-1 for cadmium, lead and zinc respectively. The sensor is greatly simplified over those recently reported such as bismuth nanoparticle modified electrodes and bismuth film coated screen printed electrodes. The scope of applications of this sensor with the inherent advances in electroanalysis coupled with the negliable toxicity of bismuth is extensive allowing high throughput electroanalysis.
引用
收藏
页码:2410 / 2414
页数:5
相关论文
共 26 条
[11]   Characterisation of commercially available electrochemical sensing platforms [J].
Kadara, Rashid O. ;
Jenkinson, Norman ;
Banks, Craig E. .
SENSORS AND ACTUATORS B-CHEMICAL, 2009, 138 (02) :556-562
[12]  
Killedar V.V., 1998, T J PHYS, V22, P825
[13]   Crystalline bismuth oxide nanorods fabricated on Pt-coated substrates using a trimethylbismuth and oxygen mixture [J].
Kim, Hyoun Woo ;
Lee, Jong Woo ;
Shim, Seung Hyun ;
Kebede, Mesfin A. ;
Lee, Chongmu .
CRYSTAL RESEARCH AND TECHNOLOGY, 2008, 43 (07) :695-699
[14]   Lithographically fabricated disposable bismuth-film electrodes for the trace determination of Pb(II) and Cd(II) by anodic stripping voltammetry [J].
Kokkinos, Christos ;
Economou, Anastasios ;
Raptis, Ioannis ;
Efstathiou, Constantinos E. .
ELECTROCHIMICA ACTA, 2008, 53 (16) :5294-5299
[15]   Mercury-free sono-electroanalytical detection of lead in human blood by use of bismuth-film-modified boron-doped diamond electrodes [J].
Kruusma, J ;
Banks, CE ;
Compton, RG .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 379 (04) :700-706
[16]   Square-wave voltammetric determination of thallium using surface modified thick-film graphite electrode with Bi nanopowder [J].
Lee, Gyroung-Ja ;
Lee, Hi Min ;
Uhm, Young Rang ;
Lee, Min Ku ;
Rhee, Chang-Kyu .
ELECTROCHEMISTRY COMMUNICATIONS, 2008, 10 (12) :1920-1923
[17]  
Pourbaix M., 1967, Atlas of electrochemical equilibria in aqueous solutions
[18]   The fabrication and characterization of a bismuth nanoparticle modified boron doped diamond electrode and its application to the simultaneous determination of cadmium(II) and lead(II) [J].
Toghill, Kathryn E. ;
Wildgoose, Gregory G. ;
Moshar, Amir ;
Mulcahy, Chris ;
Compton, Richard G. .
ELECTROANALYSIS, 2008, 20 (16) :1731-1737
[19]  
Wang BX, 2000, CONTEMP CHIN THOUGHT, V32, P18
[20]  
Wang J, 2001, ELECTROANAL, V13, P1153, DOI 10.1002/1521-4109(200110)13:14<1153::AID-ELAN1153>3.0.CO