Disposable Bismuth Oxide Screen Printed Electrodes for the High Throughput Screening of Heavy Metals

被引:94
作者
Kadara, Rashid O. [1 ]
Jenkinson, Norman [1 ]
Banks, Craig E. [1 ]
机构
[1] Manchester Metropolitan Univ, Fac Sci & Engn, Sch Biol Chem & Hlth Sci, Div Chem & Mat, Manchester M1 5GD, Lancs, England
关键词
Bismuth electrodes; Screen printing; High-throughput screening; Electroanalysis; FILM ELECTRODE; CADMIUM(II); LEAD;
D O I
10.1002/elan.200900266
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We present a simplified approach for the trace screening of toxic heavy metals utilizing bismuth oxide screen printed electrodes. The use of bismuth oxide instead of toxic mercury films facilitates the reliable sensing of lead(II), cadmium(II) and zinc(H). A linear range over 5 to 150 mu g L-1 with detection limits of 2.5 and 5 mu g L-1 are readily observed for cadmium and lead in 0.1 M HCl, respectively. Conducting a simultaneous multi-elemental voltammetric detection of zinc, cadmium and lead in a higher pH medium (0.1 M sodium acetate solution) exhibited a linear range between 10 and 150 mu g L-1 with detection limits of 5, 10 and 30 mu g L-1 for cadmium, lead and zinc respectively. The sensor is greatly simplified over those recently reported such as bismuth nanoparticle modified electrodes and bismuth film coated screen printed electrodes. The scope of applications of this sensor with the inherent advances in electroanalysis coupled with the negliable toxicity of bismuth is extensive allowing high throughput electroanalysis.
引用
收藏
页码:2410 / 2414
页数:5
相关论文
共 26 条
[1]   The determination of cysteine at Bi-powder carbon paste electrodes by cathodic stripping voltammetry [J].
Baldrianova, L. ;
Agrafiotou, P. ;
Svancara, I. ;
Vytras, K. ;
Sotiropouios, S. .
ELECTROCHEMISTRY COMMUNICATIONS, 2008, 10 (06) :918-921
[2]   Sonoelectroanalysis: investigation of bismuth-film-modified glassy carbon electrodes [J].
Banks, CE ;
Kruusma, J ;
Hyde, ME ;
Salimi, A ;
Compton, RG .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 379 (02) :277-282
[3]   Cathodic electrochemical analysis of methyl parathion at bismuth-film-modified glassy carbon electrode [J].
Du, Dan ;
Ye, Xiuping ;
Zhang, Jiande ;
Liu, Deli .
ELECTROCHIMICA ACTA, 2008, 53 (13) :4478-4484
[4]   Antimony film electrode for electrochemical stripping analysis [J].
Hocevar, Samo B. ;
Svancara, Ivan ;
Ogorevc, Bozidar ;
Vytras, Karel .
ANALYTICAL CHEMISTRY, 2007, 79 (22) :8639-8643
[5]   Novel electrode for electrochemical stripping analysis based on carbon paste modified with bismuth powder [J].
Hocevar, SB ;
Svancara, I ;
Vytras, K ;
Ogorevc, B .
ELECTROCHIMICA ACTA, 2005, 51 (04) :706-710
[6]   Bismuth film microelectrode for direct voltammetric measurement of trace cobalt and nickel in some simulated and real body fluid samples [J].
Hutton, EA ;
Ogorevc, B ;
Hocevar, SB ;
Smyth, MR .
ANALYTICA CHIMICA ACTA, 2006, 557 (1-2) :57-63
[7]   Cathodic electrochemical detection of nitrophenols at a bismuth film electrode for use in flow analysis [J].
Hutton, EA ;
Ogorevc, B ;
Smyth, MR .
ELECTROANALYSIS, 2004, 16 (19) :1616-1621
[8]   An electrochemical sensor based on the reduction of screen-printed bismuth oxide for the determination of trace lead and cadmium [J].
Hwang, Gil-Ho ;
Han, Won-Kyu ;
Park, Joon-Shik ;
Kang, Sung-Goon .
SENSORS AND ACTUATORS B-CHEMICAL, 2008, 135 (01) :309-316
[9]   Manufacturing electrochemical platforms: Direct-write dispensing versus screen printing [J].
Kadara, Rashid O. ;
Jenkinson, Norman ;
Li, Bo ;
Church, Kenneth H. ;
Banks, Craig E. .
ELECTROCHEMISTRY COMMUNICATIONS, 2008, 10 (10) :1517-1519
[10]   Development of disposable bulk-modified screen-printed electrode based on bismuth oxide for stripping chronopotentiometric analysis of lead (II) and cadmium (II) in soil and water samples [J].
Kadara, Rashid O. ;
Tothill, Ibtisam E. .
ANALYTICA CHIMICA ACTA, 2008, 623 (01) :76-81