An analysis of light-pipe system via full-scale measurements

被引:42
作者
Li, Danny H. W. [1 ]
Tsang, Ernest K. W. [1 ]
Cheung, K. L. [1 ]
Tam, C. O. [1 ]
机构
[1] City Univ Hong Kong, Dept Bldg & Construct, Bldg Energy Res Grp, Kowloon, Hong Kong, Peoples R China
关键词
Light-pipe system; Daylight; Luminous flux; Daylight penetration factor; Clearness index; OFFICE BUILDINGS; GUIDANCE SYSTEMS; HONG-KONG; DAYLIGHT; ENERGY; PERFORMANCES; DESIGN;
D O I
10.1016/j.apenergy.2009.09.008
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Daylighting is an effective sustainable development strategy to alleviating the problems in energy and the environment, and improving the qualities for visual comfort and health. In Hong Kong, many buildings are high-rise blocks constructed close to each other resulting in severe sky obstructions. Recently, a great deal of attention has been paid to the development of natural daylight exploitation products. One invention is the light-pipe system that transports natural light efficiently from outdoor into rear part of a room. However, this innovative daylighting device is not popular in subtropical Hong Kong. The main reason for such unenthusiastic responses is the lack of local data to indicate the visual performance, energy savings and design implications. A research project was initiated to evaluate these issues. The study includes field measurements of daylight illuminance in a corridor installed a number of light pipes. The results demonstrate that the light-pipe system can provide sufficient illuminance, improve the daylight uniformity and have a high potential to reduce the electric lighting energy consumption. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:799 / 805
页数:7
相关论文
共 23 条
  • [1] Tubular guidance systems for daylight: Achieved and predicted installation performances
    Al-Marwaee, Mohammed
    Carter, David
    [J]. APPLIED ENERGY, 2006, 83 (07) : 774 - 788
  • [2] [Anonymous], 2003, THESIS U NOTTINGHAM
  • [3] Daylight and energy performances of a new type of light pipe
    Canziani, R
    Peron, R
    Rossi, G
    [J]. ENERGY AND BUILDINGS, 2004, 36 (11) : 1163 - 1176
  • [4] Developments in tubular daylight guidance systems
    Carter, DJ
    [J]. BUILDING RESEARCH AND INFORMATION, 2004, 32 (03) : 220 - 234
  • [5] Design and assessment of an anidolic light-duct
    Courret, G
    Scartezzini, JL
    Francioli, D
    Meyer, JJ
    [J]. ENERGY AND BUILDINGS, 1998, 28 (01) : 79 - 99
  • [6] Quantifying energy savings in daylight responsive systems: The role of dimming electronic ballasts
    Doulos, L.
    Tsangrassoulis, A.
    Topalis, F.
    [J]. ENERGY AND BUILDINGS, 2008, 40 (01) : 36 - 50
  • [7] A design tool for predicting the performances of light pipes
    Jenkins, D
    Muneer, T
    Kubie, J
    [J]. ENERGY AND BUILDINGS, 2005, 37 (05) : 485 - 492
  • [8] An approach for estimating the carbon emissions associated with office lighting with a daylight contribution
    Jenkins, David
    Newborough, Marcus
    [J]. APPLIED ENERGY, 2007, 84 (06) : 608 - 622
  • [9] Efficient tubular light guide with two-component glazing with Lambertian diffuser and clear glass
    Kocifaj, M.
    [J]. APPLIED ENERGY, 2009, 86 (7-8) : 1031 - 1036
  • [10] An analysis of electricity end-use in air-conditioned office buildings in Hong Kong
    Lam, JC
    Li, DHW
    Cheung, SO
    [J]. BUILDING AND ENVIRONMENT, 2003, 38 (03) : 493 - 498