Is patient-specific instrumentation more precise than conventional techniques and navigation in achieving planned correction in high tibial osteotomy?

被引:43
作者
Tardy, Nicolas [1 ]
Steltzlen, Camille [2 ]
Bouguennec, Nicolas [3 ]
Cartier, Jean-Loup [4 ]
Mertl, Patrice [5 ]
Batailler, Cecile [6 ]
Hanouz, Jean-Luc [7 ]
Rochcongar, Goulven [8 ]
Fayard, Jean-Marie [9 ]
机构
[1] Clin Cedres, Ctr Osteoarticulaire Cedres, 5 Rue Trop, F-38130 Echirolles, France
[2] Hop Mignot, Serv Chirurg Orthoped, 177 Rue Versailles, F-78150 Le Chesnay, France
[3] Clin Sport Bordeaux Merignac, 2 Rue Georges Negrevergne, F-33700 Merignac, France
[4] Clin Alpes Sud, 3 Rue Antonin Coronat, F-05000 Gap, Hautes Alpes, France
[5] CHU Amiens Picardie Site Sud, Serv Chirurg Orthoped, 1 Rond Point Prof Christian Cabrol, F-80054 Amiens 1, France
[6] Hop Croix Rousse, Serv Chirurg Orthoped, 103 Grande Rue Croix Rousse, F-6931704 Lyon 04, France
[7] CHU Caen, Serv Anesthesie Reanimat, Ave Cote Nacre, F-14033 Caen, France
[8] CHU Caen, Dept Chirurg Orthoped & Traumatol, Niveau 11, Inserm U1075 COMETE Mobilite Attent Orientat & Ch, Ave Cote de Nacre, F-14033 Caen, France
[9] Hop Prive Jean Mermoz, Ctr Orthoped Santy, Ramsay Generale Sante, 24,Ave Paul Santy, F-69008 Lyon, France
[10] 15 Rue Ampere, F-92500 Rueil Malmaison, France
关键词
High tibial osteotomy; Navigation; PSI;
D O I
10.1016/j.otsr.2020.08.009
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction Preoperative planning in high tibial osteotomy (HTO) is a critical step for achieving the desired correction and a clinically satisfactory outcome. Conventional radiography, navigation assistance and patient-specific instrumentation (PSI) are the 3 means of planning, but no prospective studies have compared precision between the 3. The aims of the present study were: (1) to analyze and compare correction precision between the 3 planning approaches at 1 year's follow-up; (2) to compare results to those reported in the literature; and (3) to analyze factors influencing the achievement of planned correction. Hypothesis The study hypothesis was that PSI provides more precise and reproducible planned correction than conventional methods or navigation. Material and method Between June 2017 and June 2018, a multicenter non-randomized prospective observational study was conducted in 11 centers. One hundred and twenty-six patients with Ahlback grade I, II or III idiopathic medial tibiofemoral osteoarthritis with stable knee were included and allocated to 3 preoperative planning groups: conventional (group 1), navigation (group 2) and PSI (group 3). Mean age at surgery was 51.2 years (range, 19-69 years; median, 53.2 years); 100 male, 26 female. Complete weight-bearing radiographic work-up was performed preoperatively and at 1 year's follow-up. The PSI group also underwent CT as part of guide production. Target angular correction and mechanical Hip-Knee-Ankle (HKA) axis were set preoperatively. The main endpoint was the difference between planned HKA and HKA at a minimum 12 months. Results Mean HKA difference was 1.1 +/- 3 in group 1, 2.1 +/- 2.6 in group 2 and 0.3 +/- 3.1 in group 3. Precision was better with PSI, but not significantly when comparing all 3 groups together. On pairwise intergroup comparison, there was a significant difference only between groups 2 and 3, in favor of PSI (P = 0.011). Discussion None of the 3 techniques demonstrated superiority in achieving target correction at 1 year. The study hypothesis was thus not confirmed. All 3 techniques proved reliable and precise in HTO planning. Level of evidence III, prospective non-randomized comparative study. (C) 2020 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:S231 / S236
页数:6
相关论文
共 57 条
[11]   Opening-wedge high tibial osteotomy performed with locking plate fixation (TomoFix) and early weight-bearing but without filling the defect. A concise follow-up note of 48 cases at 10 years' follow-up [J].
Darees, M. ;
Putman, S. ;
Brosset, T. ;
Roumazeill, T. ;
Pasquier, G. ;
Migaud, H. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2018, 104 (04) :477-480
[12]  
DUGDALE TW, 1992, CLIN ORTHOP RELAT R, P248
[13]   Comparison of Closing-Wedge and Opening-Wedge High Tibial Osteotomy for Medial Compartment Osteoarthritis of the Knee A Randomized Controlled Trial with a Six-Year Follow-up [J].
Duivenvoorden, T. ;
Brouwer, R. W. ;
Baan, A. ;
Bos, P. K. ;
Reijman, M. ;
Bierma-Zeinstra, S. M. A. ;
Verhaar, J. A. N. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2014, 96A (17) :1425-1432
[14]  
Ellis R E, 1999, Comput Aided Surg, V4, P264
[15]   High reliability in digital planning of medial opening wedge high tibial osteotomy, using Miniaci's method [J].
Elson, D. W. ;
Petheram, T. G. ;
Dawson, M. J. .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (07) :2041-2048
[16]  
Escott BG, 2013, J BONE JOINT SURG AM, V95A, P2126, DOI 10.2106/JBJS.L.00989
[17]   Accuracy of 3D-planned patient specific instrumentation in high tibial open wedge valgisation osteotomy [J].
Fucentese, Sandro F. ;
Meier, Patrick ;
Jud, Lukas ;
Kochli, Gian-Luca ;
Aichmair, Alexander ;
Vlachopoulos, Lazaros ;
Furnstahl, Philipp .
JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2020, 7 (01)
[18]   Reliability of computer-assisted surgery as an intraoperative ruler in navigated high tibial osteotomy [J].
Gebhard, Florian ;
Krettek, Christian ;
Huefner, Tobias ;
Gruetzner, Paul A. ;
Stoeckle, Ulrich ;
Imhoff, Andreas B. ;
Lorenz, Stephan ;
Ljungqvist, Jan ;
Keppler, Peter .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2011, 131 (03) :297-302
[19]   Assessment of Lower Limb Length and Alignment by Biplanar Linear Radiography: Comparison With Supine CT and Upright Full-Length Radiography [J].
Guggenberger, Roman ;
Pfirrmann, Christian W. A. ;
Koch, Peter P. ;
Buck, Florian M. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 202 (02) :W161-W167
[20]   Effect of Computer Navigation on Accuracy and Reliability of Limb Alignment Correction following Open-Wedge High Tibial Osteotomy: A Meta-Analysis [J].
Han, Seung-Beom ;
Kim, Hyun Jung ;
Lee, Dae-Hee .
BIOMED RESEARCH INTERNATIONAL, 2017, 2017