Low dose contrast media in step-and-shoot coronary angiography with third-generation dual-source computed tomography : feasibility of using 30 mL of contrast media in patients with body surface area <1.7 m2

被引:7
作者
Jin, Liang [1 ]
Jie, Bing [2 ]
Gao, Yiyi [1 ]
Jiang, An'qi [1 ]
Weng, Tingwen [3 ]
Li, Ming [1 ,4 ]
机构
[1] Fudan Univ, Huadong Hosp, Radiol Dept, 221 West Yanan Rd, Shanghai, Peoples R China
[2] Tongji Univ, Shanghai Pulm Hosp, Radiol Dept, Shanghai, Peoples R China
[3] Fudan Univ, Huadong Hosp, Cardiol Dept, Shanghai, Peoples R China
[4] Fudan Univ, Inst Funct & Mol Med Imaging, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
Contrast media; coronary angiography; body surface area; coronary artery disease; computed tomography angiography; CT ANGIOGRAPHY; IMAGE QUALITY; ITERATIVE RECONSTRUCTION; INJECTION SPEED; TUBE-VOLTAGE; 70; KVP; IODINE CONCENTRATION; DIAGNOSTIC-ACCURACY; PROTOCOL; AGENT;
D O I
10.21037/qims-20-500
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Reducing contrast media volume in coronary computed tomography angiography minimizes the risk of adverse events but may compromise diagnostic image quality. We aimed to evaluate coronary computed tomography angiography's diagnostic image quality while using 30 mL of contrast media in patients with a body surface area <1.7 m(2). Methods: This prospective study included patients who underwent coronary computed tomography angiography from May 2018 to June 2019. The patients were divided into a low-dose group, who received 30 mL of contrast media, and a routine-dose group, who received contrast media based on body weight. Patient characteristics, coronary computed tomography angiography results, and quantitative and qualitative image results were assessed and compared. Results: In total, 103 patients with a body surface area <1.7 m(2) were 53 in the low-dose group and 50 in the routine-dose group. Sex, age, body surface area, body weight, and heart rate were similar between the groups (P>0.05). A contrast media volume of 30 +/- 0 mL was used for the low-dose group, and 41.62 +/- 4.59 mL was used for the routine-dose group. The low-dose group's computed tomography values were significantly different from those of the routine-dose group (P<0.05). The radiologists demonstrated agreement regarding diagnostic image quality and accuracy (kappa =0.91 and 0.85, respectively). Conclusions: Using 30 mL of contrast media for coronary computed tomography angiography in patients with a body surface area <1.7 m(2) provided a suitable diagnostic image quality for coronary artery disease diagnosis. Although radiation doses were similar between the groups, the decreased contrast media volume was likely beneficial for the patients.
引用
收藏
页码:2598 / 2609
页数:12
相关论文
共 44 条
[1]  
Achenbach S, 2017, EUR RADIOL, V27, P821, DOI 10.1007/s00330-016-4437-9
[2]   Coronary CT angiography with 80 kV tube voltage and low iodine concentration contrast agent in patients with low body weight [J].
Andreini, Daniele ;
Mushtaq, Saima ;
Conte, Edoardo ;
Segurini, Chiara ;
Guglielmo, Marco ;
Petulla, Maria ;
Volpato, Valentina ;
Annoni, Andrea ;
Baggiano, Andrea ;
Formenti, Alberto ;
Bartorelli, Antonio L. ;
Fiorentini, Cesare ;
Pepi, Mauro .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2016, 10 (04) :322-326
[3]   Contrast enhancement in cardiovascular MDCT: Effect of body weight, height, body surface area, body mass index, and obesity [J].
Bae, Kyongtae T. ;
Seeck, Brian A. ;
Hildebolt, Charles F. ;
Tao, Cheng ;
Zhu, Fang ;
Kanematsu, Masayuki ;
Woodard, Pamela K. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (03) :777-784
[4]   Lower dose and lower injection speed of iodinated contrast media: a new strategy to reduce the incidence rate of immediate hypersensitivity reactions [J].
Bohm, Ingrid B. .
QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2020, 10 (04) :883-885
[5]   Reduced iodinated contrast media dose and injection speed for CT: how much does this decrease the risk of a hypersensitivity reactions? [J].
Brockow, Knut .
QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2020, 10 (02) :537-540
[6]   Dual-source CT: effect of heart rate, heart rate variability, and calcification on image quality and diagnostic accuracy [J].
Brodoefel, Harald ;
Burgstahler, Christof ;
Tsiflikas, Ilias ;
Reimann, Anja ;
Schroeder, Stephen ;
Claussen, Claus D. ;
Heuschmid, Martin ;
Kopp, Andreas F. .
RADIOLOGY, 2008, 247 (02) :346-355
[7]  
Earls James P, 2009, J Cardiovasc Comput Tomogr, V3, P45, DOI 10.1016/j.jcct.2008.10.013
[8]   Personalization of injection protocols to the individual patient's blood volume and automated tube voltage selection (ATVS) in coronary CTA [J].
Eijsvoogel, Nienke G. ;
Hendriks, Babs M. F. ;
Willigers, Jef L. ;
Martens, Bibi ;
Carati, Luc F. ;
Horehledova, Barbora ;
Kietselaer, Bastiaan L. J. H. ;
Crijns, Harry J. G. M. ;
Wildberger, Joachim E. ;
Das, Marco .
PLOS ONE, 2018, 13 (09)
[9]   Iodine Concentration and Optimization in Computed Tomography Angiography Current Issues [J].
Faggioni, Lorenzo ;
Gabelloni, Michela .
INVESTIGATIVE RADIOLOGY, 2016, 51 (12) :816-822
[10]   High-Pitch Coronary CT Angiography at 70 kVp Adopting a Protocol of Low Injection Speed and Low Volume of Contrast Medium [J].
Feng, Ruiqi ;
Tong, Jiajie ;
Liu, Xiaofei ;
Zhao, Yu ;
Zhang, Liang .
KOREAN JOURNAL OF RADIOLOGY, 2017, 18 (05) :763-772