SAFE ZONE FOR C1 LATERAL MASS SCREWS: ANATOMIC AND RADIOLOGICAL STUDY

被引:15
|
作者
Simsek, Serkan [2 ]
Yigitkanli, Kazim [2 ]
Turba, Ulku C. [3 ]
Comert, Ayhan [1 ]
Seckin, Hakan [2 ]
Tekdemir, Ibrahim [1 ]
Elhan, Alaittin [1 ]
机构
[1] Ankara Univ, Sch Med, Dept Anat, TR-06100 Ankara, Turkey
[2] Ankara Diskapi Training & Res Hosp, Minist Hlth, Neurosurg Clin 2, Ankara, Turkey
[3] Univ Virginia Hlth Syst, Dept Radiol, Charlottesville, VA USA
关键词
C1; Internal carotid artery; Lateral mass; Longus capitis muscle; Rectus capitis anterior muscle; Safe zone; Screw; INTERNAL CAROTID-ARTERY; TRANSARTICULAR SCREW; HYPOGLOSSAL NERVE; FIXATION; PLACEMENT; ATLAS; C-1; PERFORATION; VERTEBRA; FUSION;
D O I
10.1227/01.NEU.0000351779.58845.62
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: To evaluate the possible complications of overpenetrated C1 lateral mass screws and to identify and define a "safe zone" area anterior to the C1 vertebra. METHODS: The study was performed on 10 cadavers and 50 random patients who had undergone computed tomographic scanning with contrast medium of the neck for other purposes. Atlas lateral mass screw trajectories were plotted, and the safe zone for screw placement anterior to the atlas vertebra was determined for each trajectory. RESULTS: The trajectory of the internal carotid artery was measured from its medial wall, The trajectory of the internal carotid artery according to the ideal entrance point of the screw was 11.55 +/- 4.55 degrees (range, 2-22 degrees) in the cadavers and 9.78 +/- 4.55 degrees (range, -5 to 22 degrees) bilaterally in the patients. At 15 degrees (ideal screw trajectory), the thickness of the rectus capitis anterior muscle and longus capitis muscle was 6.69 +/- 0.83 mm (range, 5.32-7.92 mm) in the cadavers and 7.29 +/- 1.90 mm (range, 0.50-13.63 mm) bilaterally in the patients. The smallest distance from the internal carotid artery to the anterior cortex of the Cl vertebra was calculated as 4.33 +/- 2.03 mm (range, 1.15-8.40 mm) bilaterally in the cadavers and 5.07 +/- 1.72 mm (range, 2.15-8.91 mm) bilaterally in radiological specimens. CONCLUSION: The internal carotid artery trajectory is lateral to the ideal entrance point of C1 lateral mass screws. The medial angulation of a screw placed in the lateral mass of C1 seemed to increase the margin of safety for the internal carotid artery. The rectus capitis anterior and longus capitis muscles may be thought of as a safe zone area for C1 lateral mass screws. At more than 25 degrees of medial angulation, the risk of perforation of the oropharyngeal wall increases.
引用
收藏
页码:1154 / 1160
页数:7
相关论文
共 50 条
  • [41] A prospective, double-blind, randomized controlled trial of treatment of atlantoaxial instability with C1 posterior arches >4 mm by comparing C1 pedicle with lateral mass screws fixation
    Yan, Liang
    He, Baorong
    Liu, Tuanjiang
    Yang, Lixue
    Hao, Dingjun
    BMC MUSCULOSKELETAL DISORDERS, 2016, 17
  • [42] Relationship Between Screw Trajectory of C1 Lateral Mass Screw and Internal Carotid Artery
    Murakami, Satona
    Mizutani, Jun
    Fukuoka, Muneyoshi
    Kato, Kenji
    Sekiya, Isato
    Okamoto, Hideki
    Abumi, Kuniyoshi
    Otsuka, Takanobu
    SPINE, 2008, 33 (24) : 2581 - 2585
  • [43] Chronic C1-C2 Rotatory Subluxation Reduced by C1 Lateral Mass Screws and C2 Translaminar Screws: A Case Report
    Lavelle, William F.
    Palomino, Kathryn
    Badve, Siddharth A.
    Albanese, Stephen A.
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2017, 37 (03) : E174 - E177
  • [44] Anatomic Determination of Optimal Entry Point and Direction For C1 Lateral Mass Screw Placement
    Blagg, Stuart E.
    Don, Angus S.
    Robertson, Peter A.
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2009, 22 (04): : 233 - 239
  • [45] Comparison of outcomes after atlantoaxial fusion with C1 lateral mass-C2 pedicle screws and C1-C2 transarticular screws
    Rajinda, Panupol
    Towiwat, Sirisomboon
    Chirappapha, Piyawat
    EUROPEAN SPINE JOURNAL, 2017, 26 (04) : 1064 - 1072
  • [46] Lateral Mass of C1 Fixation and Ponticulus-Posticus
    Ahmad, Faiz U.
    Wang, Michael Y.
    WORLD NEUROSURGERY, 2014, 82 (1-2) : E145 - E146
  • [47] Usefulness of a New Electronic Conductivity Device with a Pedicle Probe and a Multi-axis Angiography Unit for Inserting a C1 Lateral Mass Screw Safely and Tightly: A Technical Note
    Kageyama, Hiroto
    Yoshimura, Shinichi
    Matsuda, Kenichi
    Yoshida, Yasunori
    Matsukawa, Hidetoshi
    Yamada, Kiyofumi
    NEUROLOGIA MEDICO-CHIRURGICA, 2019, 59 (12) : 523 - 528
  • [48] Influence of variations of craniovertebral junction anatomy on safe C1 lateral mass and C2 pedicle screw insertion: a cadaveric and radiologic study
    Karatas, Derya
    Dagtekin, Ahmet
    Uygur, Saygi
    Barut, Irmak Tekeli
    Kara, Engin
    Esen, Kaan
    Avci, Emel
    Baskaya, Mustafa Kemal
    SURGICAL AND RADIOLOGIC ANATOMY, 2025, 47 (01)
  • [49] Clinical and radiological Comparison of treatment of atlantoaxial instability by posterior C1-C2 transarticular screw fixation or C1 lateral mass-C2 pedicle screw fixation
    Lee, Sun-Ho
    Kim, Eun Sang
    Sung, Joo-Kyung
    Park, Yeun-Mook
    Eoh, Whan
    JOURNAL OF CLINICAL NEUROSCIENCE, 2010, 17 (07) : 886 - 892
  • [50] Clinical Application of a Revised Screw Technique via the C1 Posterior Arch and Lateral Mass in the Pediatric Population
    Yi, Ping
    Dong, Liang
    Tan, Mingsheng
    Wang, Wenjun
    Tang, Xiangsheng
    Yang, Feng
    Zhang, Guangbo
    PEDIATRIC NEUROSURGERY, 2013, 49 (03) : 159 - 165