SAFE ZONE FOR C1 LATERAL MASS SCREWS: ANATOMIC AND RADIOLOGICAL STUDY

被引:15
|
作者
Simsek, Serkan [2 ]
Yigitkanli, Kazim [2 ]
Turba, Ulku C. [3 ]
Comert, Ayhan [1 ]
Seckin, Hakan [2 ]
Tekdemir, Ibrahim [1 ]
Elhan, Alaittin [1 ]
机构
[1] Ankara Univ, Sch Med, Dept Anat, TR-06100 Ankara, Turkey
[2] Ankara Diskapi Training & Res Hosp, Minist Hlth, Neurosurg Clin 2, Ankara, Turkey
[3] Univ Virginia Hlth Syst, Dept Radiol, Charlottesville, VA USA
关键词
C1; Internal carotid artery; Lateral mass; Longus capitis muscle; Rectus capitis anterior muscle; Safe zone; Screw; INTERNAL CAROTID-ARTERY; TRANSARTICULAR SCREW; HYPOGLOSSAL NERVE; FIXATION; PLACEMENT; ATLAS; C-1; PERFORATION; VERTEBRA; FUSION;
D O I
10.1227/01.NEU.0000351779.58845.62
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: To evaluate the possible complications of overpenetrated C1 lateral mass screws and to identify and define a "safe zone" area anterior to the C1 vertebra. METHODS: The study was performed on 10 cadavers and 50 random patients who had undergone computed tomographic scanning with contrast medium of the neck for other purposes. Atlas lateral mass screw trajectories were plotted, and the safe zone for screw placement anterior to the atlas vertebra was determined for each trajectory. RESULTS: The trajectory of the internal carotid artery was measured from its medial wall, The trajectory of the internal carotid artery according to the ideal entrance point of the screw was 11.55 +/- 4.55 degrees (range, 2-22 degrees) in the cadavers and 9.78 +/- 4.55 degrees (range, -5 to 22 degrees) bilaterally in the patients. At 15 degrees (ideal screw trajectory), the thickness of the rectus capitis anterior muscle and longus capitis muscle was 6.69 +/- 0.83 mm (range, 5.32-7.92 mm) in the cadavers and 7.29 +/- 1.90 mm (range, 0.50-13.63 mm) bilaterally in the patients. The smallest distance from the internal carotid artery to the anterior cortex of the Cl vertebra was calculated as 4.33 +/- 2.03 mm (range, 1.15-8.40 mm) bilaterally in the cadavers and 5.07 +/- 1.72 mm (range, 2.15-8.91 mm) bilaterally in radiological specimens. CONCLUSION: The internal carotid artery trajectory is lateral to the ideal entrance point of C1 lateral mass screws. The medial angulation of a screw placed in the lateral mass of C1 seemed to increase the margin of safety for the internal carotid artery. The rectus capitis anterior and longus capitis muscles may be thought of as a safe zone area for C1 lateral mass screws. At more than 25 degrees of medial angulation, the risk of perforation of the oropharyngeal wall increases.
引用
收藏
页码:1154 / 1160
页数:7
相关论文
共 50 条
  • [31] C1 Lateral Mass Screw Insertion With Protection of C1-C2 Venous Sinus Technical Note and Review of the Literature
    Pan, Jie
    Li, Lijun
    Qian, Lie
    Tan, Jun
    Sun, Guixin
    Li, Xin
    SPINE, 2010, 35 (21) : E1133 - E1136
  • [32] Biomechanical evaluation of C1 lateral mass and C2 translaminar bicortical screws in atlantoaxial fixation: an in vitro human cadaveric study
    Liu, Shichang
    Song, Zongrang
    Liu, Limin
    Yin, Xinhua
    Hu, Xiongke
    Yang, Ming
    Wu, Qining
    Song, Yueming
    Hao, Dingjun
    SPINE JOURNAL, 2018, 18 (04) : 674 - 681
  • [33] Posterior atlanto-axial fixation with polyaxial C1 lateral mass screws and C2 pars screws
    Payer, M.
    Luzi, M.
    Tessitore, E.
    ACTA NEUROCHIRURGICA, 2009, 151 (03) : 223 - 229
  • [34] Posterior atlanto-axial fixation with polyaxial C1 lateral mass screws and C2 pars screws
    M. Payer
    M. Luzi
    E. Tessitore
    Acta Neurochirurgica, 2009, 151 : 223 - 229
  • [35] Assessment of the C1 Lateral Mass Screw Trajectory and Position Using Plain Radiographs A Comparison With Computed Tomography
    Lee, Sang-Hun
    Park, Dae-Hyun
    Kim, Man-Ho
    Huh, Dae-Seok
    Kang, Kyung Chung
    Lee, Jung-Hee
    Suk, Kyung-Soo
    Kim, Ki-Tack
    CLINICAL SPINE SURGERY, 2016, 29 (03): : E112 - E119
  • [36] C1 lateral mass screw placement via the posterior arch: a technique comparison and anatomic analysis
    Lin, James M.
    Hipp, John A.
    Reitman, Charles A.
    SPINE JOURNAL, 2013, 13 (11) : 1549 - 1555
  • [37] C1 lateral mass screw insertion using cannulated, navigated screws: preliminary results of a novel technique
    Harel, Ran
    Kimchi, Gil
    Perry, Avital
    Knoller, Nachshon
    BRITISH JOURNAL OF NEUROSURGERY, 2023, 37 (06) : 1624 - 1627
  • [38] C1-C2 Arthrodesis With C1 Lateral Mass and C2 Parsicle Screws Combined With Interlaminar Arthrodesis and Wiring
    Rasouli, Jonathan J.
    Momin, Arbaz
    Fiani, Brian
    Shao, Jianning
    Moore, Timothy A.
    CLINICAL SPINE SURGERY, 2022, 35 (02): : 76 - 79
  • [39] Treatment for odontoid fracture with C1 lateral mass and C2pedicle screws using intraoperative orbic-3-dimensional navigation
    Zhao, Jianjun
    Xu, Peng
    Zhang, Shoutao
    Mu, Weidong
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2017, 10 (09): : 14150 - 14158
  • [40] Biomechanical Role of the C1 Lateral Mass Screws in Occipitoatlantoaxial Fixation A Finite Element Analysis
    Liu, Haibo
    Zhang, Baocheng
    Lei, Jianyin
    Cai, Xianhua
    Li, Zhiqiang
    Wang, Zhihua
    SPINE, 2016, 41 (22) : E1312 - E1318