SAFE ZONE FOR C1 LATERAL MASS SCREWS: ANATOMIC AND RADIOLOGICAL STUDY

被引:15
|
作者
Simsek, Serkan [2 ]
Yigitkanli, Kazim [2 ]
Turba, Ulku C. [3 ]
Comert, Ayhan [1 ]
Seckin, Hakan [2 ]
Tekdemir, Ibrahim [1 ]
Elhan, Alaittin [1 ]
机构
[1] Ankara Univ, Sch Med, Dept Anat, TR-06100 Ankara, Turkey
[2] Ankara Diskapi Training & Res Hosp, Minist Hlth, Neurosurg Clin 2, Ankara, Turkey
[3] Univ Virginia Hlth Syst, Dept Radiol, Charlottesville, VA USA
关键词
C1; Internal carotid artery; Lateral mass; Longus capitis muscle; Rectus capitis anterior muscle; Safe zone; Screw; INTERNAL CAROTID-ARTERY; TRANSARTICULAR SCREW; HYPOGLOSSAL NERVE; FIXATION; PLACEMENT; ATLAS; C-1; PERFORATION; VERTEBRA; FUSION;
D O I
10.1227/01.NEU.0000351779.58845.62
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: To evaluate the possible complications of overpenetrated C1 lateral mass screws and to identify and define a "safe zone" area anterior to the C1 vertebra. METHODS: The study was performed on 10 cadavers and 50 random patients who had undergone computed tomographic scanning with contrast medium of the neck for other purposes. Atlas lateral mass screw trajectories were plotted, and the safe zone for screw placement anterior to the atlas vertebra was determined for each trajectory. RESULTS: The trajectory of the internal carotid artery was measured from its medial wall, The trajectory of the internal carotid artery according to the ideal entrance point of the screw was 11.55 +/- 4.55 degrees (range, 2-22 degrees) in the cadavers and 9.78 +/- 4.55 degrees (range, -5 to 22 degrees) bilaterally in the patients. At 15 degrees (ideal screw trajectory), the thickness of the rectus capitis anterior muscle and longus capitis muscle was 6.69 +/- 0.83 mm (range, 5.32-7.92 mm) in the cadavers and 7.29 +/- 1.90 mm (range, 0.50-13.63 mm) bilaterally in the patients. The smallest distance from the internal carotid artery to the anterior cortex of the Cl vertebra was calculated as 4.33 +/- 2.03 mm (range, 1.15-8.40 mm) bilaterally in the cadavers and 5.07 +/- 1.72 mm (range, 2.15-8.91 mm) bilaterally in radiological specimens. CONCLUSION: The internal carotid artery trajectory is lateral to the ideal entrance point of C1 lateral mass screws. The medial angulation of a screw placed in the lateral mass of C1 seemed to increase the margin of safety for the internal carotid artery. The rectus capitis anterior and longus capitis muscles may be thought of as a safe zone area for C1 lateral mass screws. At more than 25 degrees of medial angulation, the risk of perforation of the oropharyngeal wall increases.
引用
收藏
页码:1154 / 1160
页数:7
相关论文
共 50 条
  • [21] C1 lateral mass screw insertion caudally from C2 nerve root - An alternate method for insertion of C1 screws: A technical note and preliminary clinical results
    Wada, Keiji
    Tamaki, Ryo
    Yui, Mitsuru
    Numaguchi, Daisuke
    Murata, Yasuaki
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2017, 22 (02) : 213 - 217
  • [22] Suggestion of a safe zone for C1 pedicle screws depending on anatomical peculiarities
    Maximilian Lenz
    Arne Harland
    Philipp Egenolf
    Akanksha Perera
    Lenhard Pennig
    Jan Bredow
    Peer Eysel
    Max Joseph Scheyerer
    European Spine Journal, 2021, 30 : 3614 - 3619
  • [23] Quantitative Assessment of the Anatomical Footprint of the C1 Pedicle Relative to the Lateral Mass: A Guide for C1 Lateral Mass Fixation
    Su, Brian W.
    Theologis, Alexander A.
    Byers, Robert H.
    Shimer, Adam L.
    Schroeder, Gregory D.
    Vaccaro, Alexander R.
    Tay, Bobby
    GLOBAL SPINE JOURNAL, 2018, 8 (05) : 507 - 511
  • [24] Lateral Mass Screw Fixation of the Atlas: Importance of Anatomy of C1 for Lateral Mass Screw Placement
    Sonntag, Volker K. H.
    WORLD NEUROSURGERY, 2010, 74 (2-3) : 270 - 271
  • [25] Impact of Starting Point and Bicortical Purchase of C1 Lateral Mass Screws on Atlantoaxial Fusion Meta-Analysis and Review of the Literature
    Elliott, Robert E.
    Tanweer, Omar
    Smith, Michael L.
    Frempong-Boadu, Anthony
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2015, 28 (07): : 242 - 253
  • [26] Subarachnoid Hemorrhage and Acute Hydrocephalus as a Complication of C1 Lateral Mass Screws
    Stovell, Matthew George
    Pillay, Robin
    SPINE, 2013, 38 (18) : E1162 - E1165
  • [27] Determining anatomically-safe corridors for placement of lateral mass screws in the first cervical vertebra of the Emirati population - a CT study
    Suresh, Dineshwary
    Naidoo, Nerissa
    Alsharhan, Rashid
    Al Bastaki, Usama
    Lakshmanan, Jeyaseelan
    Joseph, Baylis Vivek
    Prithishkumar, Ivan James
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [28] The Intersection Between Lateral Mass and Inferomedial Edge of the C1 Posterior Arch: A Reference Point for C1 Lateral Mass Screw Insertion
    Bunmaprasert, Torphong
    Puangkaew, Watcharapong
    Sugandhavesa, Nantawit
    Liawrungrueang, Wongthawat
    Riew, K. Daniel
    NEUROSPINE, 2021, 18 (02) : 328 - 335
  • [29] Superior biomechanical stability of pedicle screws compared to lateral mass screws: recommendations for bicortical positioning and enhancing bone contact in geriatric C1 vertebrae
    Leonhardt, Leon-Gordian
    Roerup, Leonie
    Kammal, Anna Lena
    Hahn, Michael
    Dreimann, Marc
    Ondruschka, Benjamin
    von Brackel, Felix Nikolai
    Rolvien, Tim
    Viezens, Lennart
    von Kroge, Simon
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2025, 20 (01):
  • [30] Three-point atlantoaxial fixation with C1-C2 transarticular screws and C1 lateral mass screws
    Harati, Ali
    Oni, Paul
    JOURNAL OF ORTHOPAEDIC SURGERY, 2019, 27 (02)