Development and evaluation of an ultrasound-guided tracking and gating system for hepatic radiotherapy

被引:13
作者
Jacso, Ferenc [1 ]
Kouznetsov, Alexei [2 ]
Smith, Wendy L. [1 ,2 ]
机构
[1] Tom Baker Canc Clin, Calgary, AB T2N 4N2, Canada
[2] Univ Calgary, Dept Phys & Astron, Calgary, AB T2N 1N4, Canada
关键词
SBRT; liver radiotherapy; respiratory gating; ultrasound; RESPIRATORY-GATED RADIOTHERAPY; ACTIVE BREATHING CONTROL; BODY RADIATION-THERAPY; LIVER-TUMORS; HEPATOCELLULAR-CARCINOMA; ABDOMINAL COMPRESSION; ORGAN MOTION; METASTASES; VERIFICATION; REDUCTION;
D O I
10.1118/1.3250893
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Respiratory motion must be accounted for daily in order to permit optimum radiotherapy of hepatic malignancies. However, existing tracking systems are often invasive or poorly tolerated by patients. The authors describe the development and validation of an ultrasound-guided tracking and gating system for stereotactic body radiation therapy of the liver. Methods: This noninvasive system is designed to determine the correlation between tumor and external fiducial motion and to verify the optimum gating level for treatment delivery daily. A tracked ultrasound probe moves with patient respiration, obtaining 2D ultrasound images of tumor motion throughout the respiratory cycle. The target volume is registered to the static radiotherapy treatment beams in order to verify optimum gating levels. These gating levels are then transferred to an existing gating system for treatment delivery. The authors examined the temporal and spatial accuracy of this system using a custom-built phantom and verified the accuracy of gating level transfer and delivery. Results: The temporal accuracy of the ultrasound-guided system was shown to be comparable to the existing clinical x-ray imaging system. Using ultrasound rather than x-rays to image internal targets provides good soft-tissue contrast without the invasiveness of implanting fiducial markers. High frame rates enable continuous monitoring of the target throughout the respiratory cycle. The authors anticipate this passive monitoring system should be well tolerated by patients. Conclusions: The system developed provides good quality video of the laboratory motion phantom and can be successfully used in gated beam delivery. (C) 2009 American Association of Physicists in Medicine. [DOI: 10.1118/1.3250893]
引用
收藏
页码:5633 / 5640
页数:8
相关论文
共 28 条
  • [21] Physical aspects of a real-time tumor-tracking system for gated radiotherapy
    Shirato, H
    Shimizu, S
    Kunieda, T
    Kitamura, K
    van Herk, M
    Kagei, K
    Nishioka, T
    Hashimoto, S
    Fujita, K
    Aoyama, H
    Tsuchiya, K
    Kudo, K
    Miyasaka, K
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (04): : 1187 - 1195
  • [22] Time delays and margins in gated radiotherapy
    Smith, Wendy L.
    Becker, Nathan
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2009, 10 (03): : 140 - 154
  • [23] EXTRAPOLATION OF NORMAL TISSUE COMPLICATION PROBABILITY FOR DIFFERENT FRACTIONATIONS IN LIVER IRRADIATION
    Tai, An
    Erickson, Beth
    Li, X. Allen
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 74 (01): : 283 - 289
  • [24] Potential benefits of eliminating planning target volume expansions for patient breathing in the treatment of liver tumors
    TenHaken, RK
    Balter, JM
    Marsh, LH
    Robertson, JM
    Lawrence, TS
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 38 (03): : 613 - 617
  • [25] Conformal radiotherapy for hepatocellular carcinoma
    Tse, R. V.
    Guha, Chandan
    Dawson, L. A.
    [J]. CRITICAL REVIEWS IN ONCOLOGY HEMATOLOGY, 2008, 67 (02) : 113 - 123
  • [26] Systematic errors in respiratory gating due to intrafraction deformations of the liver
    von Siebenthal, Martin
    Szekely, Gabor
    Lomax, Antony J.
    Cattin, Philippe C.
    [J]. MEDICAL PHYSICS, 2007, 34 (09) : 3620 - 3629
  • [27] Reduction of respiratory liver tumor motion by abdominal compression in stereotactic body frame, analyzed by tracking fiducial markers implanted in liver
    Wunderink, Wouter
    Romero, Alejandra Mendez
    De Kruijf, Willy
    De Boer, Hans
    Levendag, Peter
    Heijmen, Ben
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (03): : 907 - 915
  • [28] A novel respiratory detection method based on automated analysis of ultrasound diaphragm video
    Xu, QY
    Hamilton, RJ
    [J]. MEDICAL PHYSICS, 2006, 33 (04) : 916 - 921