Development and evaluation of an ultrasound-guided tracking and gating system for hepatic radiotherapy

被引:13
作者
Jacso, Ferenc [1 ]
Kouznetsov, Alexei [2 ]
Smith, Wendy L. [1 ,2 ]
机构
[1] Tom Baker Canc Clin, Calgary, AB T2N 4N2, Canada
[2] Univ Calgary, Dept Phys & Astron, Calgary, AB T2N 1N4, Canada
关键词
SBRT; liver radiotherapy; respiratory gating; ultrasound; RESPIRATORY-GATED RADIOTHERAPY; ACTIVE BREATHING CONTROL; BODY RADIATION-THERAPY; LIVER-TUMORS; HEPATOCELLULAR-CARCINOMA; ABDOMINAL COMPRESSION; ORGAN MOTION; METASTASES; VERIFICATION; REDUCTION;
D O I
10.1118/1.3250893
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Respiratory motion must be accounted for daily in order to permit optimum radiotherapy of hepatic malignancies. However, existing tracking systems are often invasive or poorly tolerated by patients. The authors describe the development and validation of an ultrasound-guided tracking and gating system for stereotactic body radiation therapy of the liver. Methods: This noninvasive system is designed to determine the correlation between tumor and external fiducial motion and to verify the optimum gating level for treatment delivery daily. A tracked ultrasound probe moves with patient respiration, obtaining 2D ultrasound images of tumor motion throughout the respiratory cycle. The target volume is registered to the static radiotherapy treatment beams in order to verify optimum gating levels. These gating levels are then transferred to an existing gating system for treatment delivery. The authors examined the temporal and spatial accuracy of this system using a custom-built phantom and verified the accuracy of gating level transfer and delivery. Results: The temporal accuracy of the ultrasound-guided system was shown to be comparable to the existing clinical x-ray imaging system. Using ultrasound rather than x-rays to image internal targets provides good soft-tissue contrast without the invasiveness of implanting fiducial markers. High frame rates enable continuous monitoring of the target throughout the respiratory cycle. The authors anticipate this passive monitoring system should be well tolerated by patients. Conclusions: The system developed provides good quality video of the laboratory motion phantom and can be successfully used in gated beam delivery. (C) 2009 American Association of Physicists in Medicine. [DOI: 10.1118/1.3250893]
引用
收藏
页码:5633 / 5640
页数:8
相关论文
共 28 条
  • [11] Daily ultrasound-based image-guided targeting for radiotherapy of upper abdominal malignancies
    Fuss, M
    Salter, BJ
    Cavanaugh, SX
    Fuss, C
    Sadeghi, A
    Fuller, CD
    Ameduri, A
    Hevezi, JM
    Herman, TS
    Thomas, CR
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (04): : 1245 - 1256
  • [12] Curative stereotactic body radiotherapy for liver malignancy
    Gunven, Peter
    Blomgren, Henric
    Lax, Ingmar
    Levitt, Seymour H.
    [J]. MEDICAL ONCOLOGY, 2009, 26 (03) : 327 - 334
  • [13] Four-dimensional computed tomography scan analysis of tumor and organ motion at varying levels of abdominal compression during stereotactic treatment of lung and liver
    Heinzerling, John H.
    Anderson, John F.
    Papiez, Lech
    Boike, Thomas
    Chien, Stanley
    Zhang, Geoffrey
    Abdulrahman, Ramzi
    Timmerman, Robert
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (05): : 1571 - 1578
  • [14] Time delay measurement for linac based treatment delivery in synchronized respiratory gating radiotherapy
    Jin, JY
    Yin, FF
    [J]. MEDICAL PHYSICS, 2005, 32 (05) : 1293 - 1296
  • [15] Interim analysis of a prospective phase I/II trial of SBRT for liver metastases
    Kavanagh, Brian D.
    Schefter, Tracey E.
    Cardenes, Higinia R.
    Stieber, Volker W.
    Raben, David
    Timmerman, Robert D.
    McCarter, Martin D.
    Burri, Stuart
    Nedzi, Lucien A.
    Sawyer, Timothy E.
    Gaspar, Laurie E.
    [J]. ACTA ONCOLOGICA, 2006, 45 (07) : 848 - 855
  • [16] Kemeny N, 2006, ONCOLOGY-NY, V20, P1161
  • [17] Three-dimensional motion of liver tumors using cine-magnetic resonance imaging
    Kirilova, Anna
    Lockwood, Gina
    Math, M.
    Choi, Perry
    Bana, Neelufer
    Haider, Masoom A.
    Brock, Kristy K.
    Eccles, Cynthia
    Dawson, Laura A.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (04): : 1189 - 1195
  • [18] Daily targeting of liver tumors: Screening patients with a mock treatment and using a combination of internal and external fiducials for image-guided respiratory-gated radiotherapy
    Krishnan, Sunil
    Briere, Tina Marie
    Dong, Lei
    Murthy, Ravi
    Ng, Chaan
    Balter, Peter
    Mohan, Radhe
    Gillin, Michael T.
    Beddar, A. Sam
    [J]. MEDICAL PHYSICS, 2007, 34 (12) : 4591 - 4593
  • [19] Stereotactic body radiation therapy for primary and metastatic liver tumors: A single institution phase i-ii study
    Mendez Romero, Alejandra
    Wunderink, Wouter
    Hussain, Shahid M.
    De Pooter, Jacco A.
    Heijmen, Ben J. M.
    Nowak, Peter C. J. M.
    Nuyttens, Joost J.
    Brandwijk, Rene P.
    Verhoef, Cees
    Ijzermans, Jan N. M.
    Levendag, Peter C.
    [J]. ACTA ONCOLOGICA, 2006, 45 (07) : 831 - 837
  • [20] Simultaneous tumour dose escalation and liver sparing in Stereotactic Body Radiation Therapy (SBRT) for liver tumours due to CTV-to-PTV margin reduction
    Molinelli, Silvia
    de Pooter, Jacco
    Romero, Alejandra Mendez
    Wunderink, Wouter
    Cattaneo, Mauro
    Calandrino, Riccardo
    Heijmen, Ben
    [J]. RADIOTHERAPY AND ONCOLOGY, 2008, 87 (03) : 432 - 438