Detection of false lumen perfusion at the beginning of cardiopulmonary bypass in patients undergoing repair of aortic dissection

被引:11
作者
Voci, P
Testa, G
Tritapepe, L
Menichetti, A
Caretta, Q
机构
[1] Univ Roma La Sapienza, Inst Cardiac Surg, Rome, Italy
[2] Univ Roma La Sapienza, Inst Anesthesia & Intens Care, Rome, Italy
[3] Univ Florence, Florence, Italy
关键词
aorta; dissection; perfusion; false lumen; contrast agents; echocardiography; transesophageal echocardiography; outcome; surgery; emergency;
D O I
10.1097/00003246-200006000-00026
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: In patients undergoing surgical repair of aortic dissection, false lumen perfusion during cardiopulmonary bypass may produce central nervous system damage, myocardial ischemia, aortic rupture, and death. We describe a method to detect false lumen perfusion at the beginning of retrograde aortic perfusion that may prevent these complications. Design: Sonicated albumin microbubbles (8 mt) were injected through a side branch of the extracorporeal circulation line to detect true lumen and/or false lumen perfusion of the thoracic aorta at the beginning of cardiopulmonary bypass. Transesophageal echocardiography was used to image aortic perfusion. Setting: The study was performed in a cardiac surgery theater. Patients: A total of 27 consecutive patients undergoing operation for Type I aortic dissection were studied, interventions: All patients underwent surgical repair of aortic dissection and retrograde aortic perfusion through one femoral artery. Measurements and Main Results: Patients were divided into three groups: Group I, those having adequate true lumen perfusion: brisk appearance and washout of contrast in the true lumen with no, poor, or delayed opacification of the false lumen; Group II, those having mixed true lumen and false lumen perfusion: simultaneous opacification of both lumens; Group Ill, those having inappropriate false lumen perfusion: same criteria as for adequate true lumen perfusion applied to the false lumen. The true lumen was perfused in 13 patients, both lumens in 11 patients, and false lumen alone in three patients. In these three patients, cannulation was repeated through the contralateral femoral artery with restoration of true lumen perfusion; the first patient died of diffuse cerebral ischemic damage and renal failure, another one experienced temporary postoperative monoparesis, and the fast had no neurologic sequelae. Conclusions: Contrast echocardiography allows immediate detection of retrograde aortic perfusion during cardiopulmonary bypass and may help prevent neurologic complications and death in patients with Type I dissection.
引用
收藏
页码:1841 / 1846
页数:6
相关论文
共 18 条
  • [1] ASSESSMENT OF MYOCARDIAL PERFUSION DURING CABG SURGERY WITH 2-DIMENSIONAL TRANSESOPHAGEAL CONTRAST ECHOCARDIOGRAPHY
    ARONSON, S
    LEE, BK
    WIENCEK, JG
    FEINSTEIN, SB
    ROIZEN, MF
    KARP, RB
    ELLIS, JE
    [J]. ANESTHESIOLOGY, 1991, 75 (03) : 433 - 440
  • [2] Ehrlich M, 1998, CIRCULATION, V98, pII294
  • [3] EFFECT OF MEDICAL AND SURGICAL THERAPY ON AORTIC DISSECTION EVALUATED BY TRANSESOPHAGEAL ECHOCARDIOGRAPHY - IMPLICATIONS FOR PROGNOSIS AND THERAPY
    ERBEL, R
    OELERT, H
    MEYER, J
    PUTH, M
    MOHRKATOLY, S
    HAUSMANN, D
    DANIEL, W
    MAFFEI, S
    CARUSO, A
    COVINO, FE
    DIALETTO, G
    IACONO, C
    COTRUFO, M
    BARONI, M
    TERRAZZI, M
    FRASER, A
    TAAMS, M
    SLAVICH, G
    SUTHERLAND, G
    ROELANDT, J
    MARCAGGI, X
    [J]. CIRCULATION, 1993, 87 (05) : 1604 - 1615
  • [4] FEINSTEIN SB, 1984, J AM COLL CARDIOL, V4, P595, DOI 10.1016/S0735-1097(84)80107-2
  • [5] SAFETY AND EFFICACY OF A NEW TRANSPULMONARY ULTRASOUND CONTRAST AGENT - INITIAL MULTICENTER CLINICAL-RESULTS
    FEINSTEIN, SB
    CHEIRIF, J
    TENCATE, FJ
    SILVERMAN, PR
    HEIDENREICH, PA
    DICK, C
    DESIR, RM
    ARMSTRONG, WF
    QUINONES, MA
    SHAH, PM
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (02) : 316 - 324
  • [6] Feinstein SB, 1991, CARDIAC IMAGING COMP, P557
  • [7] OPERATIVE MANAGEMENT OF ACUTE AORTIC-ARCH DISSECTION USING PROFOUND HYPOTHERMIA AND CIRCULATORY ARREST
    GRAHAM, JM
    STINNETT, DM
    [J]. ANNALS OF THORACIC SURGERY, 1987, 44 (02) : 192 - 198
  • [8] Griepp RB, 1997, ANN THORAC SURG, V64, P1675
  • [9] AORTIC DISSECTION - THE LAST FRONTIER
    KHANDHERIA, BK
    [J]. CIRCULATION, 1993, 87 (05) : 1765 - 1768
  • [10] ADVANCES IN AORTIC-ARCH SURGERY
    LAAS, J
    JURMANN, MJ
    HEINEMANN, M
    BORST, HG
    [J]. ANNALS OF THORACIC SURGERY, 1992, 53 (02) : 227 - 232