A semi-theoretical model for energy efficiency assessment of air source heat pump systems

被引:34
作者
Xu, Zhaowei [1 ,2 ]
Li, Hao [1 ,2 ]
Shao, Shuangquan [3 ]
Xu, Wei [1 ,2 ]
Wang, Zhichao [1 ,2 ]
Wang, Yichao [1 ,2 ]
Sun, Xiaoyu [1 ,2 ]
Yang, Qiang [1 ,2 ]
Xu, Ce [1 ,2 ]
Zhao, Wenyuan [1 ,2 ]
机构
[1] State Key Lab Bldg Safety & Built Environm, Beijing 100013, Peoples R China
[2] China Acad Bldg Res, Beijing 100013, Peoples R China
[3] Huazhong Univ Sci & Technol, Sch Energy & Power Engn, Wuhan 430074, Peoples R China
关键词
Air source heat pump; Heat pump modeling; Cycling losses; Thermodynamic perfectibility; Field trial; CYCLING LOSSES; ON-OFF; PERFORMANCE;
D O I
10.1016/j.enconman.2020.113667
中图分类号
O414.1 [热力学];
学科分类号
摘要
Although significant progress has been made in relation to air source heat pump (ASHP) modeling, it is difficult to reflect the actual dynamic characteristics of the start-up process by a completely theoretical model, and a regression model cannot reflect the energy efficiency differences between systems intuitively. A semi-theoretical model for fixed speed ASHP which considers the modifications of no-load power consumption, cycling losses and defrost discount has been developed based on the statistical analysis of field monitoring data. Thermodynamic perfectibility was introduced to evaluate the steady-state performance at continuous operation. By taking the running and cycle time as input parameters, it is possible to relate the operation mode to system energy efficiency. In the verification of the seasonal coefficient of performance, the error is <10%. The identification of the cycling losses from field monitoring data illustrated that the impact of cycling losses drops off with the increase of the running time and the percentage of running time in an ON-OFF cycle. In energy efficiency diagnosis applications, the quantified losses concluded that the least energy efficient project is caused by no-load consumption and cycling losses. The application of the simulation integrated with building heating system illustrates that the proposed model cooperated with iterative algorithm can realize minute-by-minute dynamic simulation. This paper provides a foundation for operation strategy research and energy efficiency analysis of the fixed speed ASHP system.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Energy transfer procession in an air source heat pump unit during defrosting
    Song Mengjie
    Xu Xiangguo
    Mao Ning
    Deng Shiming
    Xu Yingjie
    APPLIED ENERGY, 2017, 204 : 679 - 689
  • [42] Investigation of annual energy performance of a VWV air source heat pump system
    Wang, R. Z.
    Jin, Z. Q.
    Zhai, X. Q.
    Jin, C. C.
    Luo, W. L.
    Eikevik, T. M.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 85 : 383 - 394
  • [43] Validation of unglazed transpired solar collector assisted air source heat pump simulation model
    Janusevicius, Karolis
    Streckiene, Giedre
    Bielskus, Juozas
    Martinaitis, Vytautas
    INTERNATIONAL SCIENTIFIC CONFERENCE - ENVIRONMENTAL AND CLIMATE TECHNOLOGIES, CONECT 2015, 2016, 95 : 167 - 174
  • [44] AN EXPERIMENTAL ANALYSIS OF AIR SOURCE HEAT PUMP WATER HEATER
    Ozturk, M. Mete
    Erbay, L. Berrin
    ISI BILIMI VE TEKNIGI DERGISI-JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2012, 32 (01) : 117 - 127
  • [45] Review of the Coupled System of Solar and Air Source Heat Pump
    Meng, Xin
    Zhou, Xin
    Li, Zhenyu
    ENERGIES, 2024, 17 (23)
  • [46] Performance investigation on an air source heat pump system with latent heat thermal energy storage
    Lin, Ying
    Fan, Yubin
    Yu, Meng
    Jiang, Long
    Zhang, Xuejun
    ENERGY, 2022, 239
  • [47] Experimental investigation of an air source heat pump with multigroup heat pipe radiators
    Xu, Shuxue
    Niu, Jianhui
    Ma, Guoyuan
    SOLAR ENERGY, 2023, 260 : 137 - 146
  • [48] A new energy analysis tool for ground source heat pump systems
    Michopoulos, A.
    Kyriakis, N.
    ENERGY AND BUILDINGS, 2009, 41 (09) : 937 - 941
  • [49] Atmospheric air quality in Beijing improved by application of air source heat pump (ASHP) systems
    Xu, Zhaowei
    Liu, Fang
    Xu, Wei
    Wang, Zhichao
    Yang, Yingxia
    Xu, Ce
    Wu, Pin
    Li, Xiaofeng
    JOURNAL OF CLEANER PRODUCTION, 2020, 257
  • [50] Feasibility and optimization of defrosting control method with differential pressure sensor for air source heat pump systems
    Chung, Yoong
    Na, Sun Ik
    Choi, Jongmin
    Kim, Min Soo
    APPLIED THERMAL ENGINEERING, 2019, 155 : 461 - 469