A semi-theoretical model for energy efficiency assessment of air source heat pump systems

被引:34
|
作者
Xu, Zhaowei [1 ,2 ]
Li, Hao [1 ,2 ]
Shao, Shuangquan [3 ]
Xu, Wei [1 ,2 ]
Wang, Zhichao [1 ,2 ]
Wang, Yichao [1 ,2 ]
Sun, Xiaoyu [1 ,2 ]
Yang, Qiang [1 ,2 ]
Xu, Ce [1 ,2 ]
Zhao, Wenyuan [1 ,2 ]
机构
[1] State Key Lab Bldg Safety & Built Environm, Beijing 100013, Peoples R China
[2] China Acad Bldg Res, Beijing 100013, Peoples R China
[3] Huazhong Univ Sci & Technol, Sch Energy & Power Engn, Wuhan 430074, Peoples R China
关键词
Air source heat pump; Heat pump modeling; Cycling losses; Thermodynamic perfectibility; Field trial; CYCLING LOSSES; ON-OFF; PERFORMANCE;
D O I
10.1016/j.enconman.2020.113667
中图分类号
O414.1 [热力学];
学科分类号
摘要
Although significant progress has been made in relation to air source heat pump (ASHP) modeling, it is difficult to reflect the actual dynamic characteristics of the start-up process by a completely theoretical model, and a regression model cannot reflect the energy efficiency differences between systems intuitively. A semi-theoretical model for fixed speed ASHP which considers the modifications of no-load power consumption, cycling losses and defrost discount has been developed based on the statistical analysis of field monitoring data. Thermodynamic perfectibility was introduced to evaluate the steady-state performance at continuous operation. By taking the running and cycle time as input parameters, it is possible to relate the operation mode to system energy efficiency. In the verification of the seasonal coefficient of performance, the error is <10%. The identification of the cycling losses from field monitoring data illustrated that the impact of cycling losses drops off with the increase of the running time and the percentage of running time in an ON-OFF cycle. In energy efficiency diagnosis applications, the quantified losses concluded that the least energy efficient project is caused by no-load consumption and cycling losses. The application of the simulation integrated with building heating system illustrates that the proposed model cooperated with iterative algorithm can realize minute-by-minute dynamic simulation. This paper provides a foundation for operation strategy research and energy efficiency analysis of the fixed speed ASHP system.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] ENERGY AND EXERGY ANALYSIS OF AN AIR SOURCE HEAT PUMP UNDER VARIABLE AMBIENT CONDITIONS
    Streckiene, Giedre
    Kropas, Tomas
    Mikucioniene, Ruta
    Dziugaite-Tumeniene, Rasa
    JOURNAL OF ENVIRONMENTAL ENGINEERING AND LANDSCAPE MANAGEMENT, 2024, 32 (01) : 12 - 21
  • [22] Influence of the water tank size and air source heat pump size on the energy saving potential of the energy storage heating system
    Lyu, Weihua
    Wang, Zhichao
    Li, Xiaofeng
    Deng, Gaofeng
    Xu, Zhaowei
    Li, Hao
    Yang, Yingxia
    Zhan, Binfei
    Zhao, Mingyang
    JOURNAL OF ENERGY STORAGE, 2022, 55
  • [23] Investigation on the efficiency degradation characterization of low ambient temperature air source heat pump under partial load operation
    Xu, Zhaowei
    Li, Hao
    Xu, Wei
    Shao, Shuangquan
    Wang, Zhichao
    Gou, Xiaoxi
    Zhao, Mingyang
    Li, Jiandong
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2022, 133 : 99 - 110
  • [24] Energy efficiency in a ground source heat pump with variable speed drives
    Del Col, Davide
    Azzolin, Marco
    Benassi, Giacomo
    Mantovan, Mauro
    ENERGY AND BUILDINGS, 2015, 91 : 105 - 114
  • [25] Dimensionless and thermodynamic modelling of integrated photovoltaics-air source heat pump systems
    Wang, Chenguang
    Gong, Guangcai
    Su, Huan
    Yu, Chuck Wah
    SOLAR ENERGY, 2015, 118 : 175 - 185
  • [26] Energy Use and Greenhouse Gas Emissions of Air-Source Heat Pump and Innovative Ground-Source Air Heat Pump in a Cold Climate
    Mattinen, Maija K.
    Nissinen, Ari
    Hyysalo, Sampsa
    Juntunen, Jouni K.
    JOURNAL OF INDUSTRIAL ECOLOGY, 2015, 19 (01) : 61 - 70
  • [27] Air source heat pump in-situ performance
    Chesser, Michael
    Lyons, Padraig
    O'Reilly, Padraic
    Carroll, Paula
    ENERGY AND BUILDINGS, 2021, 251
  • [28] Simulation and Optimization Study on an Energy Efficiency Improvement Strategy of an Air Source Heat Pump Under Australian Standards
    Xu, Jiangtao
    Liu, Cheng
    Liu, Xiaojun
    Sun, Xiaoxiao
    Li, Yongjian
    ENERGIES, 2025, 18 (06)
  • [29] Efficiency Investigation and Energy Saving of Vertical Ground Source Heat Pump
    Desmedt, Johan
    Van Bael, Johan
    STROJARSTVO, 2010, 52 (04): : 405 - 409
  • [30] Comparative thermal performances of a ground source heat pump and a variable capacity air source heat pump systems for sustainable houses
    Safa, Amir A.
    Fung, Alan S.
    Kumar, Rakesh
    APPLIED THERMAL ENGINEERING, 2015, 81 : 279 - 287