A semi-theoretical model for energy efficiency assessment of air source heat pump systems

被引:34
|
作者
Xu, Zhaowei [1 ,2 ]
Li, Hao [1 ,2 ]
Shao, Shuangquan [3 ]
Xu, Wei [1 ,2 ]
Wang, Zhichao [1 ,2 ]
Wang, Yichao [1 ,2 ]
Sun, Xiaoyu [1 ,2 ]
Yang, Qiang [1 ,2 ]
Xu, Ce [1 ,2 ]
Zhao, Wenyuan [1 ,2 ]
机构
[1] State Key Lab Bldg Safety & Built Environm, Beijing 100013, Peoples R China
[2] China Acad Bldg Res, Beijing 100013, Peoples R China
[3] Huazhong Univ Sci & Technol, Sch Energy & Power Engn, Wuhan 430074, Peoples R China
关键词
Air source heat pump; Heat pump modeling; Cycling losses; Thermodynamic perfectibility; Field trial; CYCLING LOSSES; ON-OFF; PERFORMANCE;
D O I
10.1016/j.enconman.2020.113667
中图分类号
O414.1 [热力学];
学科分类号
摘要
Although significant progress has been made in relation to air source heat pump (ASHP) modeling, it is difficult to reflect the actual dynamic characteristics of the start-up process by a completely theoretical model, and a regression model cannot reflect the energy efficiency differences between systems intuitively. A semi-theoretical model for fixed speed ASHP which considers the modifications of no-load power consumption, cycling losses and defrost discount has been developed based on the statistical analysis of field monitoring data. Thermodynamic perfectibility was introduced to evaluate the steady-state performance at continuous operation. By taking the running and cycle time as input parameters, it is possible to relate the operation mode to system energy efficiency. In the verification of the seasonal coefficient of performance, the error is <10%. The identification of the cycling losses from field monitoring data illustrated that the impact of cycling losses drops off with the increase of the running time and the percentage of running time in an ON-OFF cycle. In energy efficiency diagnosis applications, the quantified losses concluded that the least energy efficient project is caused by no-load consumption and cycling losses. The application of the simulation integrated with building heating system illustrates that the proposed model cooperated with iterative algorithm can realize minute-by-minute dynamic simulation. This paper provides a foundation for operation strategy research and energy efficiency analysis of the fixed speed ASHP system.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Efficiency assessment of variable speed air source heat pump heating systems: A hybrid data-driven and theoretical approach
    Li, Hao
    Xu, Zhaowei
    Yang, Qiang
    Wang, Zhichao
    Shao, Shuangquan
    Xu, Ce
    Yang, Yingxia
    Li, Jiandong
    JOURNAL OF BUILDING ENGINEERING, 2024, 87
  • [2] Impact of water volume on the energy saving potential of air source heat pump systems
    Li, Hao
    Yang, Qiang
    Xu, Zhaowei
    Shao, Shuangquan
    Wang, Zhichao
    Sun, Xiaoyu
    Wang, Yichao
    Xu, Ce
    Zhao, Wenyuan
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 130 : 128 - 139
  • [3] Theoretical analysis on ground source heat pump and air source heat pump systems by the concepts of cool and warm exergy
    Li, Rongling
    Ooka, Ryozo
    Shukuya, Masanori
    ENERGY AND BUILDINGS, 2014, 75 : 447 - 455
  • [4] Performance of Air Source Heat Pump Domestic Hot Water System under Seasonal Energy Efficiency Assessment
    Yin Y.-D.
    Xu L.-S.
    Huang X.-Y.
    Zhu D.-S.
    Sun J.-F.
    Gao Xiao Hua Xue Gong Cheng Xue Bao/Journal of Chemical Engineering of Chinese Universities, 2018, 32 (04): : 933 - 939
  • [5] Assessment of the Energy Performance of an Air Source Heat Pump by Response Surface Methodology
    Ciarrocchi, Eleonora
    Arteconi, Alessia
    Zheng, Xu
    Polonara, Fabio
    Wang, Ruzhu
    8TH INTERNATIONAL CONFERENCE ON APPLIED ENERGY (ICAE2016), 2017, 105 : 439 - 444
  • [6] A review on hybrid physics and data-driven modeling methods applied in air source heat pump systems for energy efficiency improvement
    Guo, Yanhua
    Wang, Ningbo
    Shao, Shuangquan
    Huang, Congqi
    Zhang, Zhentao
    Li, Xiaoqiong
    Wang, Youdong
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2024, 204
  • [7] Energy Efficiency Analysis of Preheating Boiler Feedwater System with Air Source Heat Pump
    Wang Linjun
    Liu Wei
    Zhang Dong
    Gao Zhangwei
    ENERGY DEVELOPMENT, PTS 1-4, 2014, 860-863 : 586 - +
  • [8] A review of ground-source heat pump systems with heat pipes for energy efficiency in buildings
    Wu, Siyuan
    Dai, Yuchao
    Lie, Xiaolu
    Oppong, Francis
    Xu, Cangsu
    CLEANER ENERGY FOR CLEANER CITIES, 2018, 152 : 413 - 418
  • [9] Enhancing partial load efficiency of air source heat pump heating systems: A comprehensive review of magnitude, influencing factors, and improvement strategies
    Li, Hao
    Xu, Zhaowei
    Yang, Qiang
    Shao, Shuangquan
    Wang, Zhichao
    Xu, Ce
    Wu, Chunling
    Lyu, Weihua
    JOURNAL OF BUILDING ENGINEERING, 2024, 97
  • [10] Continuous heating of an air-source heat pump during defrosting and improvement of energy efficiency
    Jang, Ji Young
    Bae, Heung Hee
    Lee, Seung Jun
    Ha, Man Yeong
    APPLIED ENERGY, 2013, 110 : 9 - 16