Comparison between spray towers with and without fin coils for air dehumidification using triethylene glycol solutions and development of the mass-transfer correlations

被引:58
作者
Chung, TW [1 ]
Wu, H [1 ]
机构
[1] Chung Yuan Christian Univ, Dept Chem Engn, Chungli 320, Taiwan
关键词
D O I
10.1021/ie990630d
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Spray towers with and without fin coils were compared for their efficiency in air dehumidification using triethylene glycol (TEG) solutions. Experiments were conducted using different air flow rates, liquid flow rates, temperature and air humidities, and aqueous TEG solution concentrations. Theoretically, an absorber with fin coils reduces the temperature of the desiccant solution, which leads to a greater amount of water vapor removal from the air. It was evident that the performance of the spray tower with fin coils was better than that of the spray tower without fin coils under similar operating conditions. Mass-transfer correlations were developed for both systems, which considered the changes in gas-liquid flow ratio, temperature, TEG concentration, and some physical properties. A dimensional analysis of the process variables was carried out using the Buckingham Pi method to obtain the dimensionless groups of the correlations. Most of the values predicted by the correlations were within +/-10% of the experimental data.
引用
收藏
页码:2076 / 2084
页数:9
相关论文
共 23 条
[2]   Modeling the absorption of SO2 in a spray scrubber using the penetration theory [J].
Brogren, C ;
Karlsson, HT .
CHEMICAL ENGINEERING SCIENCE, 1997, 52 (18) :3085-3099
[3]   EFFICIENCY OF A LIQUID DESICCANT DEHUMIDIFICATION SYSTEM REGENERATED BY USING SOLAR COLLECTORS REGENERATORS WITH PHOTOVOLTAIC FANS [J].
CHUNG, TW ;
WU, WY ;
YAN, WJ ;
HUANG, CL .
SEPARATION SCIENCE AND TECHNOLOGY, 1995, 30 (06) :1039-1045
[4]   Comparison between random and structured packings for dehumidification of air by lithium chloride solutions in a packed column and their heat and mass transfer correlations [J].
Chung, TW ;
Ghosh, TK ;
Hines, AL .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 1996, 35 (01) :192-198
[5]  
*DOW CHEM CO, 1981, GUID GLYC
[6]   CALCULATION OF HEAT AND MASS-TRANSFER COEFFICIENTS IN A PACKED TOWER OPERATING WITH A DESICCANT-AIR CONTACT SYSTEM [J].
GANDHIDASAN, P ;
KETTLEBOROUGH, CF ;
ULLAH, MR .
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 1986, 108 (02) :123-128
[7]  
Geankoplis C.J., 1993, TRANSPORT PROCESSES, V3rd
[8]   SIMULATION-MODEL OF WET FLUE-GAS DESULFURIZATION PLANT [J].
GERBEC, M ;
STERGARSEK, A ;
KOCJANCIC, R .
COMPUTERS & CHEMICAL ENGINEERING, 1995, 19 :S283-S286
[9]  
GROSSO S, 1980, DRYING 80, V1, P468
[10]  
Howell J. R., 1987, Solar Energy Utilization. Proceedings of the NATO Advanced Study Institute, P374