Migratory low velocity intradural lumbosacral spinal bullet causing cauda equina syndrome: report of a case and review of literature

被引:9
作者
Baldawa, Sachin [1 ,3 ]
Shivpuje, Vijay [2 ]
机构
[1] Yashodhara Superspecial Hosp, Dept Neurosurg, Solapur, Maharashtra, India
[2] Yashodhara Superspecial Hosp, Dept Gen Surg, Solapur, Maharashtra, India
[3] Baldawa Hosp, Dept Neurosurg, Solapur 413002, Maharashtra, India
关键词
Spinal bullet; Intrathecal bullet; Migratory bullet; Spine trauma; Cauda equina syndrome; GUNSHOT INJURIES; RETAINED BULLET; CORD-INJURY; FRAGMENTS;
D O I
10.1007/s00586-016-4913-6
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background Migration of the bullet within the spinal subarachnoid space has long been recognized as unusual complication of spinal gunshot injury. Objective We report a case of migratory low velocity intradural lumbosacral spinal bullet causing cauda equina syndrome. The relevant literature is reviewed and all cases of migratory spinal bullet are summarised, and management strategies are discussed. Study design Literature review. Methods A 32-year-old male suffered abdominal gunshot injury for which emergency laparotomy and repair of colonic perforation were performed. The bullet was seen lodged within the sacral spinal canal behind the S1 vertebral body. The probable entry point was at L2-L3 level. Caudal migration of the bullet within the spinal subarachnoid space leads to the appearance of cauda equina syndrome. Results Bullet was retrieved following upper sacral and lower lumbar laminectomy. Prone positioning of the patient had lead to cranial migration of the bullet at L4 level which was confirmed on fluoroscopy. Laminectomy had to be extended upwards with the patient in reverse Trendelenburg position for bullet removal. Conclusions Caudal migration of the bullet within the lumbosacral subarachnoid space results in cauda equina syndrome. Surgical retrieval of the bullet ensures the early recovery of neurological symptoms. Prone patient positioning can influence bullet location. Intraoperative fluoroscopy prior to skin incision is essential in addition to preoperative imaging to locate the bullet and thus avoid incorrect lower level laminectomy. Trapping the bullet after durotomy using suction and dissector in reverse Trendelenburg position is a useful aid in bullet removal.
引用
收藏
页码:S128 / S135
页数:8
相关论文
共 36 条
  • [1] Ajmal Saad, 2009, Spine J, V9, pe5, DOI 10.1016/j.spinee.2009.06.009
  • [2] SPONTANEOUS MIGRATION OF AN INTRA-CRANICAL BULLET TO THE CERVICAL SPINAL-CANAL CAUSING LHERMITTES SIGN - CASE-REPORT
    ARASIL, E
    TASCIOGLU, AO
    [J]. JOURNAL OF NEUROSURGERY, 1982, 56 (01) : 158 - 159
  • [3] DELAYED NEUROLOGICAL SYMPTOMS FROM THE SPONTANEOUS MIGRATION OF A BULLET IN THE LUMBOSACRAL SPINAL-CANAL - CASE-REPORT
    AVCI, SB
    ACIKGOZ, B
    GUNDOGDU, S
    [J]. PARAPLEGIA, 1995, 33 (09): : 541 - 542
  • [4] Intrathecal migratory foreign body without neurological deficit after a gunshot wound
    Ben-Galim, Peleg
    Reitman, Charles A.
    [J]. SPINE JOURNAL, 2008, 8 (02) : 404 - 407
  • [5] Bordon G, 2014, CASE REP ORTHOP
  • [6] Migration of a bullet in the spinal canal
    Cagavi, Ferda
    Kalayci, Murat
    Seckiner, Ilker
    Cagavi, Zeynep
    Guel, Sanser
    Atasoy, Hueseyin Tugrul
    Demircan, Nejat
    Acikgoez, Bektas
    [J]. JOURNAL OF CLINICAL NEUROSCIENCE, 2007, 14 (01) : 74 - 76
  • [7] Castillo-Rangel C, 2010, NEUROCIRUGIA, V21, P326
  • [8] Migrating intrathecal high-velocity projectile
    Chan, Yuen T. C.
    Al-Mahfoudh, Rafid
    Thennakon, Shymica
    Eldridge, Paul
    Pillay, Robin
    [J]. BRITISH JOURNAL OF NEUROSURGERY, 2015, 29 (04) : 585 - 586
  • [9] CAUDA-EQUINA SYNDROME OCCURRING 9 YEARS AFTER A GUNSHOT INJURY TO THE SPINE - A CASE-REPORT
    CONWAY, JE
    CROFFORD, TW
    TERRY, AF
    PROTZMAN, RR
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (05) : 760 - 763
  • [10] Gunshot injuries in the spine
    de Barros Filho, T. E. P.
    Cristante, A. F.
    Marcon, R. M.
    Ono, A.
    Bilhar, R.
    [J]. SPINAL CORD, 2014, 52 (07) : 504 - 510