Repeatability of Doppler ultrasound measurements of hindlimb blood flow in halothane anaesthetised horses

被引:10
|
作者
Raisis, AL
Young, LE
Meire, H
Walsh, K
Taylor, PM
Lekeux, P
机构
[1] Anim Hlth Trust, Ctr Equine Studies, Newmarket CB8 8JH, Suffolk, England
[2] Kings Coll Hosp London, Dept Radiol, London SE5 9RS, England
[3] Univ Cambridge, Dept Clin Vet Med, Cambridge CB3 0ES, England
关键词
horse; anaesthesia; blood flow; Doppler ultrasound; repeatability;
D O I
10.2746/042516400776563662
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
The purpose of this study was to determine the repeatability of femoral blood flow recorded using Doppler ultrasound in anaesthetised horses. Doppler ultrasound of the femoral artery and vein was performed in 6 horses anaesthetised with halothane and positioned in left lateral recumbency. Velocity spectra, recorded using low pulse repetition frequency, were used to calculate time-averaged mean velocity (TAV), velocity of component a (TaVa), velocity of component b (TaVb), volumetric flow, early diastolic deceleration slope (EDDS) and pulsatility index (PI), Within-patient variability was determined for sequential Doppler measurements recorded during a single standardised anaesthetic episode. Within-patient variability was also determined for Doppler and cardiovascular measurements recorded during 4 separate standardised anaesthetic episodes performed at intervals of at least one month. Within-patient variation during a single anaesthetic episode was small. Coefficients of variation (cv) were <12.5% for arterial measurements and <17% for venous measurements. Intraclass correlation coefficient was >0.75 for all measurements. No significant change was observed in measurements of cardiovascular function suggesting that within-patient variation observed during a single anaesthetic episode was due to measurement error. In contrast, within-patient variation during 4 separate anaesthetic episodes was marked (cv>17%) for most Doppler measurements obtained from arteries and veins. Variation in measurements of cardiovascular function were marked (cv>20%), suggesting that there is marked biological variation in central and peripheral haemodynamics during different anaesthetic episodes. Therefore the results of this study show that Doppler ultrasound is a noninvasive, repeatable method for measuring blood velocity, volumetric flow and indices of peripheral resistance in femoral vessels of anaesthetised horses. However, marked biological variation in haemodynamic measurements between different anaesthetic episodes could limit the ability of Doppler ultrasound to detect differences between anaesthetic agents. Ultimately, detection of differences in central and peripheral haemodynamics associated with different anaesthetic agents depends on the magnitude of the change observed. Further studies are warranted to determine the ability of this technique to detect differences in blood flow during administration of different anaesthetic agents.
引用
收藏
页码:239 / 246
页数:8
相关论文
共 50 条
  • [41] Improved determination of vascular blood flow shear rate using Doppler ultrasound
    Farison, JB
    Begeman, GA
    SallesCunha, SX
    Beebe, HG
    PHYSIOLOGY AND FUNCTION FROM MULTIDIMENSIONAL IMAGES - MEDICAL IMAGING 1997, 1997, 3033 : 235 - 246
  • [42] Renal blood flow during exercise: understanding its measurement with Doppler ultrasound
    Rocha, Marcos P.
    Mentetzides, Sandro H.
    Drew, Rachel C.
    JOURNAL OF APPLIED PHYSIOLOGY, 2023, 134 (04) : 1004 - 1010
  • [43] Neural network analysis of Doppler ultrasound blood flow signals: A pilot study
    Wright, IA
    Gough, NAJ
    Rakebrandt, F
    Wahab, M
    Woodcock, JP
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (05) : 683 - 690
  • [44] Doppler ultrasound to detect pulpal blood flow changes during local anaesthesia
    Yoon, M. J.
    Lee, S. J.
    Kim, E.
    Park, S. H.
    INTERNATIONAL ENDODONTIC JOURNAL, 2012, 45 (01) : 83 - 87
  • [45] SIMPLE SYSTEM FOR AUTOMATIC INTERMITTENT RECORDING OF BLOOD-FLOW IN FEMORODISTAL BYPASS GRAFTS USING DOPPLER ULTRASOUND
    THRUSH, AJ
    EVANS, DH
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1990, 28 (02) : 193 - 195
  • [46] A Robust Doppler Spectral Envelope Detection Technique for Automated Blood Flow Measurements
    Kathpalia, Aditi
    Karabiyik, Yucel
    Simensen, Bente
    Tegnander, Eva
    Eik-Nes, Sturla
    Torp, Hans
    Ekroll, Ingvild Kinn
    Kiss, Gabriel
    2015 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2015,
  • [47] New Simple Phenomenological Model for Laser Doppler Measurements of Blood Flow in Tissue
    Lapitan, Denis
    Rogatkin, Dmitry
    Persheyev, Saydulla
    Rogatkin, Andrey
    PROCEEDINGS OF THE 10TH INTERNATIONAL JOINT CONFERENCE ON BIOMEDICAL ENGINEERING SYSTEMS AND TECHNOLOGIES, VOL 1: BIODEVICES, 2017, : 98 - 103
  • [48] LASER DOPPLER MEASUREMENTS OF CUTANEOUS BLOOD-FLOW IN AGING MICE AND RATS
    MONTEIRORIVIERE, NA
    BANKS, YB
    BIRNBAUM, LS
    TOXICOLOGY LETTERS, 1991, 57 (03) : 329 - 338
  • [49] The evaluation of corpus luteum blood flow using color-flow Doppler ultrasound for early pregnancy diagnosis in bovine embryo recipients
    Utt, M. D.
    Johnson, G. L., III
    Beal, W. E.
    THERIOGENOLOGY, 2009, 71 (04) : 707 - 715
  • [50] Blood flow measurements at different depths using photoplethysmography and laser Doppler techniques
    Bergstrand, Sara
    Lindberg, Lars Goran
    Ek, Anna-Christina
    Linden, Maria
    Lindgren, Margareta
    SKIN RESEARCH AND TECHNOLOGY, 2009, 15 (02) : 139 - 147