Repeatability of Doppler ultrasound measurements of hindlimb blood flow in halothane anaesthetised horses

被引:10
|
作者
Raisis, AL
Young, LE
Meire, H
Walsh, K
Taylor, PM
Lekeux, P
机构
[1] Anim Hlth Trust, Ctr Equine Studies, Newmarket CB8 8JH, Suffolk, England
[2] Kings Coll Hosp London, Dept Radiol, London SE5 9RS, England
[3] Univ Cambridge, Dept Clin Vet Med, Cambridge CB3 0ES, England
关键词
horse; anaesthesia; blood flow; Doppler ultrasound; repeatability;
D O I
10.2746/042516400776563662
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
The purpose of this study was to determine the repeatability of femoral blood flow recorded using Doppler ultrasound in anaesthetised horses. Doppler ultrasound of the femoral artery and vein was performed in 6 horses anaesthetised with halothane and positioned in left lateral recumbency. Velocity spectra, recorded using low pulse repetition frequency, were used to calculate time-averaged mean velocity (TAV), velocity of component a (TaVa), velocity of component b (TaVb), volumetric flow, early diastolic deceleration slope (EDDS) and pulsatility index (PI), Within-patient variability was determined for sequential Doppler measurements recorded during a single standardised anaesthetic episode. Within-patient variability was also determined for Doppler and cardiovascular measurements recorded during 4 separate standardised anaesthetic episodes performed at intervals of at least one month. Within-patient variation during a single anaesthetic episode was small. Coefficients of variation (cv) were <12.5% for arterial measurements and <17% for venous measurements. Intraclass correlation coefficient was >0.75 for all measurements. No significant change was observed in measurements of cardiovascular function suggesting that within-patient variation observed during a single anaesthetic episode was due to measurement error. In contrast, within-patient variation during 4 separate anaesthetic episodes was marked (cv>17%) for most Doppler measurements obtained from arteries and veins. Variation in measurements of cardiovascular function were marked (cv>20%), suggesting that there is marked biological variation in central and peripheral haemodynamics during different anaesthetic episodes. Therefore the results of this study show that Doppler ultrasound is a noninvasive, repeatable method for measuring blood velocity, volumetric flow and indices of peripheral resistance in femoral vessels of anaesthetised horses. However, marked biological variation in haemodynamic measurements between different anaesthetic episodes could limit the ability of Doppler ultrasound to detect differences between anaesthetic agents. Ultimately, detection of differences in central and peripheral haemodynamics associated with different anaesthetic agents depends on the magnitude of the change observed. Further studies are warranted to determine the ability of this technique to detect differences in blood flow during administration of different anaesthetic agents.
引用
收藏
页码:239 / 246
页数:8
相关论文
共 50 条
  • [1] Variability of Doppler ultrasound measurements of hindlimb blood flow in conscious horses
    Raisis, AL
    Young, LE
    Meire, HB
    Taylor, PM
    Walsh, K
    Lekeux, P
    EQUINE VETERINARY JOURNAL, 2000, 32 (02) : 125 - 132
  • [2] Measurements of hindlimb blood flow recorded using Doppler ultrasound during administration of vasoactive agents in halothane-anesthetized horses
    Raisis, AL
    Young, LE
    Meire, HB
    Taylor, PM
    Blissitt, KJ
    Marlin, D
    Lekeux, P
    VETERINARY RADIOLOGY & ULTRASOUND, 2000, 41 (01) : 64 - 72
  • [3] Repeatability of Doppler ultrasonographic measurement of equine digital blood flow
    Menzies-Gow, Nicola J.
    Marr, Celia M.
    VETERINARY RADIOLOGY & ULTRASOUND, 2007, 48 (03) : 281 - 285
  • [4] Repeatability of laser Doppler measurements of cutaneous blood flow in clinical pharmacology studies
    Maison, P
    Demolis, P
    Giudicelli, JF
    FUNDAMENTAL & CLINICAL PHARMACOLOGY, 1996, 10 (03) : 319 - 320
  • [5] Repeatability of popliteal blood flow and lower limb vascular conductance at rest and exercise during body tilt using Doppler ultrasound
    Villar, R.
    Hughson, R. L.
    PHYSIOLOGICAL MEASUREMENT, 2013, 34 (03) : 291 - 306
  • [6] Flow Rate and Low Hematocrit Measurements for In Vitro Blood Processing With Doppler Ultrasound
    Pialot, Baptiste
    Gachelin, Jeremie
    Tanter, Mickael
    Provost, Jean
    Couture, Olivier
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2020, 67 (07) : 1293 - 1302
  • [7] Ultrasound Doppler vector tomography measurements of directional blood flow
    Jansson, T
    Almqvist, M
    Strahlen, K
    Eriksson, R
    Sparr, G
    Persson, HW
    Lindstrom, K
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (01) : 47 - 57
  • [8] Measurements of common iliac arterial blood flow in Anurans using Doppler ultrasound
    Willens, Scott
    Dupree, Sloan H.
    Stoskopf, Michael K.
    Lewbart, Gregory A.
    JOURNAL OF ZOO AND WILDLIFE MEDICINE, 2006, 37 (02) : 97 - 101
  • [9] REPEATABILITY OF TRANSCRANIAL DOPPLER MEASUREMENTS OF ARTERIAL BLOOD-FLOW VELOCITIES IN HEALTHY-SUBJECTS
    DEMOLIS, P
    CHALON, S
    GIUDICELLI, JF
    CLINICAL SCIENCE, 1993, 84 (06) : 599 - 604
  • [10] Reconstruction of maximum blood flow velocity waveforms from Doppler ultrasound measurements
    Fernando, KL
    Mathews, VJ
    Clark, EB
    SECOND JOINT EMBS-BMES CONFERENCE 2002, VOLS 1-3, CONFERENCE PROCEEDINGS: BIOENGINEERING - INTEGRATIVE METHODOLOGIES, NEW TECHNOLOGIES, 2002, : 124 - 125