Behaviour of Cold Formed Steel Built-Up Channel Columns Strengthened Using CFRP

被引:7
|
作者
Naganathan, Sivakumar [1 ]
Chakravarthy, H. G. Nahushananda [2 ]
Anuar, Noor Amalina [3 ]
Kalavagunta, Sreedhar [4 ]
Bin Mustapha, Kamal Nasharuddin [3 ]
机构
[1] Sri Sivasubramaniya Nadar Coll Engn, Dept Civil Engn, Kanchipuram 603110, Tamil Nadu, India
[2] Siddaganga Inst Technol, Dept Civil Engn, Tumkuru 572103, Karnataka, India
[3] Univ Tenaga Nas, Kajang, Malaysia
[4] Bentley Syst Singapore Pvt Ltd, Singapore, Singapore
关键词
Built-up column; Cold formed steel; Failure mode; CFRP; CAPACITY; DESIGN; JOINTS; BEAMS;
D O I
10.1007/s13296-019-00293-5
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents experimental findings of carbon fibre reinforced polymer (CFRP) strengthened cold-formed steel built-up channels subjected to axial load. In order to sensitively detect the buckling strengths and failure modes, twenty-four built-up columns were tested in which twelve columns were unadorned and another twelve columns were strengthened using CFRP sheets. The columns were tested for ultimate load, lateral displacement and failure modes. Tension coupon tests were conducted to determine the material properties of test specimens. The experimental results were compared with the design load calculated according to AISI S100-16 specification and are found to be in good agreement. It is established that the use of CFRP for strengthening increases the ultimate load and delays the buckling.
引用
收藏
页码:415 / 424
页数:10
相关论文
共 50 条
  • [31] Effect of GFRP strengthening on the flexural behaviour of cold-formed steel built-up beams
    Dar, A. R.
    INNOVATIVE INFRASTRUCTURE SOLUTIONS, 2022, 7 (01)
  • [32] Mechanical Performance of Built-Up Columns Composed of Four Cold-Formed Square Steel Tubes
    Chen, Xiaomiao
    Xia, Junwu
    Xu, Bo
    Ma, Renwei
    APPLIED SCIENCES-BASEL, 2019, 9 (06):
  • [33] Compressive behavior study of cruciform cold-formed steel built-up columns with web stiffeners
    Chen, Ming
    Geng, Yu
    Li, Bu-Shuan
    Hu, Fang-Qi
    Zhang, Xiang-Yu
    Sun, Yi
    STRUCTURES, 2025, 71
  • [34] Investigation on the behaviour and strength of cold-formed steel web stiffened built-up battened columns
    M. Anbarasu
    K. Kanagarasu
    S. Sukumar
    Materials and Structures, 2015, 48 : 4029 - 4038
  • [35] Experimental investigation of cold-formed steel built-up closed section columns with web stiffeners
    Zhang, Jia-Hui
    Young, Ben
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2018, 147 : 380 - 392
  • [36] Experimental study on the composite action in sheathed and bare built-up cold-formed steel columns
    Fratamico, David C.
    Torabian, Shahabeddin
    Zhao, Xi
    Rasmussen, Kim J. R.
    Schafer, Benjamin W.
    THIN-WALLED STRUCTURES, 2018, 127 : 290 - 305
  • [37] Cold-formed steel battened built-up columns: Experimental behaviour and verification of different design rules developed
    Dar, A. R.
    Vijayanand, S.
    Anbarasu, M.
    Dar, M. Adil
    ADVANCES IN STRUCTURAL ENGINEERING, 2022, 25 (02) : 321 - 335
  • [38] Prediction of ultimate load carrying capacity of short cold-formed steel built-up lipped channel columns using machine learning approach
    Hema, H.
    Chakravarthy, H. G. Nahushananda
    Naganna, Sujay Raghavendra
    SADHANA-ACADEMY PROCEEDINGS IN ENGINEERING SCIENCES, 2022, 47 (04):
  • [39] Numerical Study on the Structural Integrity of Built-up Cold-Formed Steel Battened Columns
    Dar, M. Adil
    Sahoo, Dipti Ranjan
    Jain, Arvind K.
    STRUCTURAL INTEGRITY ASSESSMENT, ICONS 2018, 2020, : 815 - 823
  • [40] Experimental study on fire resistance of cold-formed steel built-up box columns
    Yang, Jingjie
    Wang, Weiyong
    Shi, Yu
    Xu, Lei
    THIN-WALLED STRUCTURES, 2020, 147