Behaviour of Cold Formed Steel Built-Up Channel Columns Strengthened Using CFRP

被引:7
作者
Naganathan, Sivakumar [1 ]
Chakravarthy, H. G. Nahushananda [2 ]
Anuar, Noor Amalina [3 ]
Kalavagunta, Sreedhar [4 ]
Bin Mustapha, Kamal Nasharuddin [3 ]
机构
[1] Sri Sivasubramaniya Nadar Coll Engn, Dept Civil Engn, Kanchipuram 603110, Tamil Nadu, India
[2] Siddaganga Inst Technol, Dept Civil Engn, Tumkuru 572103, Karnataka, India
[3] Univ Tenaga Nas, Kajang, Malaysia
[4] Bentley Syst Singapore Pvt Ltd, Singapore, Singapore
关键词
Built-up column; Cold formed steel; Failure mode; CFRP; CAPACITY; DESIGN; JOINTS; BEAMS;
D O I
10.1007/s13296-019-00293-5
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents experimental findings of carbon fibre reinforced polymer (CFRP) strengthened cold-formed steel built-up channels subjected to axial load. In order to sensitively detect the buckling strengths and failure modes, twenty-four built-up columns were tested in which twelve columns were unadorned and another twelve columns were strengthened using CFRP sheets. The columns were tested for ultimate load, lateral displacement and failure modes. Tension coupon tests were conducted to determine the material properties of test specimens. The experimental results were compared with the design load calculated according to AISI S100-16 specification and are found to be in good agreement. It is established that the use of CFRP for strengthening increases the ultimate load and delays the buckling.
引用
收藏
页码:415 / 424
页数:10
相关论文
共 34 条
[1]  
[Anonymous], 2016, S10016 AISI IR STEEL
[2]  
[Anonymous], E8 ASTM
[3]  
ASTM, D88202 ASTM INT
[4]   Axial capacity and design of thin-walled steel SHS strengthened with CFRP [J].
Bambach, M. R. ;
Jama, H. H. ;
Elchalakani, M. .
THIN-WALLED STRUCTURES, 2009, 47 (10) :1112-1121
[5]   Adhesively bonded joints in composite materials: an overview [J].
Banea, M. D. ;
da Silva, L. F. M. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART L-JOURNAL OF MATERIALS-DESIGN AND APPLICATIONS, 2009, 223 (L1) :1-18
[6]  
Chakravarthy N, 2017, JURNALTEKNOLOGI, V78, P1
[7]   Strengthening of tensile steel members and bolted joints using adhesively bonded CFRP plates [J].
Colombi, P ;
Poggi, C .
CONSTRUCTION AND BUILDING MATERIALS, 2006, 20 (1-2) :22-33
[8]   Experimental investigation of built-up cold-formed steel section battened columns [J].
Dabaon, Mohamed ;
Ellobody, Ehab ;
Ramzy, Khaled .
THIN-WALLED STRUCTURES, 2015, 92 :137-145
[9]  
Davison B., 2011, STEEL DESIGNERS MANU
[10]   Environmental durability of a CFRP system for strengthening steel structures [J].
Dawood, Mina ;
Rizkalla, Sami .