Temporal and spatial variation of PM2.5 in indoor air monitored by low-cost sensors

被引:69
作者
Shen, Huizhong [1 ,2 ]
Hou, Weiying [1 ]
Zhu, Yaqi [1 ]
Zheng, Shuxiu [1 ]
Ainiwaer, Subinuer [1 ]
Shen, Guofeng [1 ]
Chen, Yilin [1 ,2 ]
Cheng, Hefa [1 ]
Hu, Jianying [1 ]
Wan, Yi [1 ]
Tao, Shu [1 ]
机构
[1] Peking Univ, Coll Urban & Environm Sci, Lab Earth Surface Proc, Sino French Inst Earth Syst Sci, Beijing 100871, Peoples R China
[2] Georgia Inst Technol, Sch Civil & Environm Engn, Atlanta, GA 30332 USA
基金
美国国家科学基金会; 中国国家自然科学基金;
关键词
Indoor air quality; Particulate matter; Spatial distribution; Temporal trend; Low-cost sensor; Cooking; PARTICULATE MATTER; PARTICLES; EXPOSURE; QUALITY; HOMES; POLLUTANTS; COOKING; OUTDOOR; DETERMINANTS; EMISSIONS;
D O I
10.1016/j.scitotenv.2021.145304
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Indoor air pollution has significant adverse health impacts, but its spatiotemporal variations and source contributions are not well quantified. In this study, we used low-cost sensors to measure PM2.5 concentrations in a typical apartment in Beijing. The measurements were conducted at 15 indoor sites and one outdoor site on 1-minute temporal resolution (convert to 10-minute averages for data analysis) from March 14 to 24, 2020. Based on these highly spatially-and temporally-resolved data, we characterized spatiotemporal variations and source contributions of indoor PM2.5 in this apartment. It was found that indoor particulate matter predominantly originates from outdoor infiltration and cooking emissions with the latter contributing more fine particles. Indoor PM2.5 concentrations were found to be correlated with ambient levels but were generally lower than those outdoors with an average I/O of 0.85. The predominant indoor source was cooking, leading to occasional high spikes. The variations observed in most rooms lagged behind those measured outdoors and in the studied kitchen. Differences between rooms were found to depend on pathway distances from sources. On average, outdoor sources contributed 36% of indoor PM2.5, varying extensively over time and among rooms. From observed PM2.5 concentrations at the indoor sites, source strengths, and pathway distances, a multivariate regression model was developed to predict spatiotemporal variations of PM2.5. The model explains 79% of the observed variation and can be used to dynamically simulate PM2.5 concentrations at any site indoors. The model's simplicity suggests the potential for regional-scale application for indoor air quality modeling. (C) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页数:9
相关论文
共 53 条
[1]   Characterization of indoor particle sources: A study conducted in the metropolitan Boston area [J].
Abt, E ;
Suh, HH ;
Allen, G ;
Koutrakis, P .
ENVIRONMENTAL HEALTH PERSPECTIVES, 2000, 108 (01) :35-44
[2]   Laboratory Evaluation of the Shinyei PPD42NS Low-Cost Particulate Matter Sensor [J].
Austin, Elena ;
Novosselov, Igor ;
Seto, Edmund ;
Yost, Michael G. .
PLOS ONE, 2015, 10 (09)
[3]   Effects of low-level inhalation exposure to carbon dioxide in indoor environments: A short review on human health and psychomotor performance [J].
Azuma, Kenichi ;
Kagi, Naoki ;
Yanagi, U. ;
Osawa, Haruki .
ENVIRONMENT INTERNATIONAL, 2018, 121 :51-56
[4]   Indoor and Outdoor Levels and Sources of Submicron Particles (PM1) at Homes in Edmonton, Canada [J].
Bari, Md. Aynul ;
Kindzierski, Warren B. ;
Wallace, Lance A. ;
Wheeler, Amanda J. ;
MacNeill, Morgan ;
Heroux, Marie-Eve .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2015, 49 (11) :6419-6429
[5]   Using Low-cost Sensors to Quantify the Effects of Air Filtration on Indoor and Personal Exposure Relevant PM2.5 Concentrations in Beijing, China [J].
Barkjohn, Karoline K. ;
Bergin, Michael H. ;
Norris, Christina ;
Schauer, James J. ;
Zhang, Yinping ;
Black, Maril yn ;
Hu, Min ;
Zhang, Junfeng .
AEROSOL AND AIR QUALITY RESEARCH, 2020, 20 (02) :297-313
[6]   Precision and Accuracy of a Direct-Reading Miniaturized Monitor in PM2.5 Exposure Assessment [J].
Borghi, Francesca ;
Spinazze, Andrea ;
Campagnolo, Davide ;
Rovelli, Sabrina ;
Cattaneo, Andrea ;
Cavallo, Domenico M. .
SENSORS, 2018, 18 (09)
[7]   Miniaturized Monitors for Assessment of Exposure to Air Pollutants: A Review [J].
Borghi, Francesca ;
Spinazze, Andrea ;
Rovelli, Sabrina ;
Campagnolo, Davide ;
Del Buono, Luca ;
Cattaneo, Andrea ;
Cavallo, Domenico M. .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2017, 14 (08)
[8]   Particulate-bound polycyclic aromatic hydrocarbon sources and determinants in residential homes [J].
Cattaneo, Andrea ;
Fermo, Paola ;
Urso, Patrizia ;
Grazia-Perrone, Maria ;
Piazzalunga, Andrea ;
Tarlassi, Jessica ;
Carrer, Paolo ;
Cavallo, Domenico Maria .
ENVIRONMENTAL POLLUTION, 2016, 218 :16-25
[9]   Emission Rates of Multiple Air Pollutants Generated from Chinese Residential Cooking [J].
Chen, Chen ;
Zhao, Yuejing ;
Zhao, Bin .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2018, 52 (03) :1081-1087
[10]   Review of relationship between indoor and outdoor particles: I/O ratio, infiltration factor and penetration factor [J].
Chen, Chun ;
Zhao, Bin .
ATMOSPHERIC ENVIRONMENT, 2011, 45 (02) :275-288